Supported acquisition environment
Scanner manufacturers: All
exact submission · checked 2026-09-01Confirm currently supported software versions, protocols, and site-specific acquisition configurations.
FDA-cleared profile
Aidoc Medical, Ltd.
Authorized purpose: Notification-only triage of adult head CTA for suspected complete large-vessel and medium-vessel occlusions; compressed previews are informational and the full study remains required for diagnosis.
Product overview
Authorized purpose: Notification-only triage of adult head CTA for suspected complete large-vessel and medium-vessel occlusions; compressed previews are informational and the full study remains required for diagnosis.
Overview status: Source-reviewed overview
Clinical role: Notification-only triage of adult head CTA for suspected complete large-vessel and medium-vessel occlusions; compressed previews are informational and the full study remains required for diagnosis.
Evidence from the reviewed source record: Aidoc conducted a retrospective, blinded, multicenter study with the BriefCase software to evaluate the software's performance in identifying head CTA images containing Vessel Occlusion (VO) in 342 cases from 5 US-based clinical sites. Ground truth was determined by 3 expert US board certified Neurologists reviewers using majority voting. Sensitivity was 91.3% (95% CI: 83.6%, 96.2%) and specificity was 85.6% (95% CI: 80.6%, 89.7%).
Clinical details
Start with the authorized purpose, then verify how it fits your service line and reading workflow.
Exact FDA decision-summary packet reviewed on 2026-09-19; existing wording is supported without expansion.
Patient-population text reported in the exact-submission ACR model card; institutional setting may still require vendor confirmation.
Conservative normalization of explicit wording in an exact-submission source.
Exact FDA decision-summary packet reviewed on 2026-09-19; existing wording is supported without expansion.
Exact FDA decision-summary packet reviewed on 2026-09-19; existing wording is supported without expansion.
The exact packet's comparison table states the inclusion and exclusion boundary and slice thickness for the subject device.
Regulatory identity
The FDA listing establishes the regulatory identity. It does not by itself establish local workflow fit, pricing, security, or performance in your environment.
Exact FDA decision-summary packet reviewed on 2026-09-19; existing wording is supported without expansion.
Exact FDA decision-summary packet reviewed on 2026-09-19; existing wording is supported without expansion.
Implementation
Use these fields to structure a vendor demo, security review, and implementation estimate.
Normalized from the prior exact-submission review. Confirm interface versions and local compatibility during technical evaluation.
Deployment category preserved from the prior exact-submission review; hosting region, data flow, and current commercial configuration still require vendor confirmation.
Exact-release security controls, data retention, hosting boundaries, and scoped assurance documentation require vendor confirmation.
Current training prerequisites, competency checks, and support commitments for the exact configuration require vendor confirmation.
Current drift, quality, uptime, alert, escalation, and incident-response commitments for the exact configuration require vendor confirmation.
Scanner manufacturers: All
exact submission · checked 2026-09-01Confirm currently supported software versions, protocols, and site-specific acquisition configurations.
ACR AI Central provides an exact-submission model card for BriefCase; FDA labeling remains controlling for clinical use, limitations, and performance.
exact submission · checked 2026-09-08Evidence
Metrics are shown only when they are tied to a source, endpoint, population, and tested product version. Candidate literature without exact product and version linkage is not shown as product evidence.
The exact packet reports the retrospective multicenter study, ground-truth review, and primary endpoint metrics.
Model sensitivity reported by ACR AI Central. Review endpoint, threshold, study population, and tested version before comparison.
Model specificity reported by ACR AI Central. Review endpoint, threshold, study population, and tested version before comparison.
No contextualized exact-version metric has completed evidence review. Regulatory-document values, when available, are shown above with their limitations.
K220709
ACR AI Central summarizes the regulatory study; consult the exact FDA materials before comparative use.
Costs and setup
These are common procurement questions; unknown values remain visible until a source supports them.
No public price or quote for the exact K220709 configuration was established in this review.
No exact-product payer policy, coding instruction, or payment determination was established; eligibility must be evaluated by payer, site of service, and use case.
Safety and lifecycle
Recall and adverse-event records are shown only after product matching. Adverse-event reports do not establish incidence or causality.
Buyer worksheet
Research record
This audit distinguishes completed source review from fields that have not yet been researched.
The refreshed discovery snapshot contains 20 PubMed and 6 ClinicalTrials.gov candidate records. Discovery metadata alone does not establish exact tested-product, version, population, and endpoint applicability, so all candidates remain quarantined and none was promoted. The current discovery snapshot contains 20 PubMed and 6 ClinicalTrials.gov candidate records; its dated, count-matched human screening remains current. Unlinked candidates remain quarantined. Native FDA recall identifiers produced 0 postmarket candidate records; 0 have been reviewed (0 published, 0 rejected) and 0 remain unreviewed.
Candidate leads were screened against the exact product and tested version. Unlinked records remain quarantined.
Source classes: fda ai list, fda decision summary, acr ai central product, fda device recall, literature index, trial registry, fda decision summary packet, pubmed, clinical trials, openfda device recall
Sources & history
Open the ledger for source dates, scope, and research-record updates.
Scope: identity, clinicalUse, modality, anatomy, workflow, evidence, implementation, purpose, intendedUsers, input, output, limitations, evidenceSummary
Scope: regulatoryIdentity, modalityContext
Scope: intendedUsers, careSetting, output, limitations, reportedSensitivity, reportedSpecificity, evidenceSummary, anatomy, evidenceStudies, implementationCapabilities
Scope: evidenceDiscovery
Scope: evidenceDiscovery, studyStatus
Scope: recallDiscovery, nativeSubmissionMatching
Scope: postmarketSafety
Regulatory record
510(k)
Research record
fda record reviewed
Editorial review
Source-reviewed editorial overlay
Alternatives
Aidoc Medical, Ltd.
BriefCase is a radiological computer aided triage and notification software indicated for use in the analysis of head CTA images in adults or transitional adolescents aged 18 and...
Aidoc Medical, Ltd.
BriefCase is a radiological computer aided triage and notification software indicated for use in the analysis of head CTA images. The device is intended to assist hospital...
GuideAI Health
Passive workflow prioritization for studies with imaging patterns consistent with possible total arterial occlusion in the specified vessels; not primary diagnosis, screening,...
Aidoc Medical, Ltd.
Adult head CTA or mCTA triage for suspected complete large-vessel and medium-vessel occlusion.