Supported acquisition environment
Scanner manufacturers: All
exact submission · checked 2026-09-01Confirm currently supported software versions, protocols, and site-specific acquisition configurations.
FDA-cleared profile
Aidoc Medical, Ltd.
BriefCase is a radiological computer-aided triage and notification software indicated for use in the analysis of frontal chest X-ray (CXR) images in adults or transitional adolescents aged 18 and older. The device is intended to assist hospital networks and appropriately trained medical specialists in workflow triage by flagging and communicating suspected positive cases of vertically malpositioned endotracheal tube (ETT) in relation to the carina. Findings are flagged when the ETT distal tip is assessed as being more than 5 cm above the carina, less than 2 cm above the carina, or when it is below the carina (i.e., in the right or left mainstem bronchus). The device assesses solely the vertical position of the ETT distal tip relative to the carina, does not factor patient positioning, and cannot detect esophageal intubation. The device does not provide results when the carina is not well visualized on the x-ray image. The device does not discriminate types of ETTs, as such a properly positioned double lumen ETT may trigger a false prioritization alert. BriefCase uses an artificial intelligence algorithm to analyze images and highlight cases with detected findings on a Stand-Alone Performance application in parallel to the ongoing standard of care image interpretation. The user is presented with notifications for cases with suspected findings. Notifications include compressed preview images that are meant for informational purposes only and not intended for diagnostic use beyond notification. The device does not alter the original medical image and is not intended to be used as a diagnostic device.
Clinical fit
Start with the authorized purpose, then verify how it fits your service line and reading workflow.
Exact-submission indication text from the ACR AI Central model card. FDA labeling remains controlling.
Intended-user text reported in the exact-submission ACR model card.
Patient-population text reported in the exact-submission ACR model card; institutional setting may still require vendor confirmation.
Conservative normalization of explicit wording in an exact-submission source.
Conservative normalization of explicit wording in an exact-submission source.
Clinical output reported in the exact-submission ACR model card.
Limitations and supported-acquisition details reported in the exact-submission ACR model card.
Regulatory identity
The FDA listing establishes the regulatory identity. It does not by itself establish local workflow fit, pricing, security, or performance in your environment.
Imaging modality reported in the exact-submission ACR AI Central model card.
Anatomy normalized from explicit exact-submission ACR model-card wording.
Implementation
Use these fields to structure a vendor demo, security review, and implementation estimate.
Normalized from the prior exact-submission review. Confirm interface versions and local compatibility during technical evaluation.
Deployment category preserved from the prior exact-submission review; hosting region, data flow, and current commercial configuration still require vendor confirmation.
FDA authorization does not establish the current commercial security posture. Request data-flow diagrams, hosting and retention details, access controls, audit logging, attestations, and incident-response documentation.
Training, onboarding, competency, and support commitments are commercial implementation details that require current vendor documentation.
Local acceptance testing, production monitoring, drift review, update control, and incident escalation require a current vendor and site-specific governance plan.
Scanner manufacturers: All
exact submission · checked 2026-09-01Confirm currently supported software versions, protocols, and site-specific acquisition configurations.
Evidence
Metrics are shown only when they are tied to a source, endpoint, population, and tested product version.
Structured study metadata from the exact-submission ACR model card; this is not an independent evidence synthesis.
Model sensitivity reported by ACR AI Central. Review endpoint, threshold, study population, and tested version before comparison.
Model specificity reported by ACR AI Central. Review endpoint, threshold, study population, and tested version before comparison.
No contextualized exact-version metric has completed evidence review. Regulatory-document values, when available, are shown above with their limitations.
Stand-Alone Performance · Adult
exact submission · Tested version: Exact product version not reported; regulatory study summarized for FDA submission K221330 · n=921 · 5 sites · Independence not establishedK221330
ACR AI Central summarizes the regulatory study; consult the exact FDA materials before comparative use.
Economics and lifecycle
These are common procurement questions; unknown values remain visible until a source supports them.
FDA submission materials do not establish current commercial pricing. Request the pricing unit, term, minimum commitment, implementation fees, and included support from the vendor.
Determine whether any product-specific CPT/HCPCS pathway exists and separate it from billing for the underlying imaging service.
Safety and lifecycle
Recall and adverse-event records are shown only after product matching. Adverse-event reports do not establish incidence or causality.
No native submission-identifier match was found in the checked openFDA radiology recall snapshot. Product-name, manufacturer, and adverse-event searches remain necessary; this does not establish that no recall or safety report exists.
Buyer worksheet
Research record
This audit distinguishes completed source review from fields that have not yet been researched.
Exact-submission ACR model-card fields were normalized under the current provenance rules; vendor and independent-study confirmation remain distinct. Automated exact-name discovery found 20 PubMed and 6 ClinicalTrials.gov candidate records. Candidates require human product and version matching; zero candidates is not evidence that no studies exist. Native FDA recall identifiers produced 0 postmarket candidate records; 0 have been reviewed (0 published, 0 rejected) and 0 remain unreviewed.
Candidate leads remain unpublished until a human confirms the exact product and tested version.
Source classes: fda ai list, fda decision summary, acr ai central product, pubmed, clinical trials, openfda device recall
Sources
Sources accessed through 2026-09-02.
Alternatives
Ever Fortune.AI, Co., Ltd.
FDA product code QAS identifies this device class as Radiological Computer-Assisted Triage And Notification Software. Radiological computer-assisted triage and notification...
Vuno Inc.
FDA product code QFM identifies this device class as Radiological Computer-Assisted Prioritization Software For Lesions. Radiological computer-assisted prioritization software for...
Milvue
FDA product code QFM identifies this device class as Radiological Computer-Assisted Prioritization Software For Lesions. Radiological computer-assisted prioritization software for...
Annalise-AI Pty Ltd
FDA product code QFM identifies this device class as Radiological Computer-Assisted Prioritization Software For Lesions. Radiological computer-assisted prioritization software for...