Evidence status: each field states its source quality, applicability, and review date. Research pending, information not established, and vendor documentation pending remain distinct outcomes.
Product overview
Start with the essentials
Authorized purpose: Adult contrast-enhanced brain CT triage for suspected brain aneurysm findings at least 3.0 mm.
Overview status: Source-reviewed overview
What does this software do?Authorized purpose: Adult contrast-enhanced brain CT triage for suspected brain aneurysm findings at least 3.0 mm.
Which images or clinical context are in scope?Modality: CT/CTA Anatomy or clinical context: Brain Input: Filtered DICOM contrast-enhanced CT images including the brain; adults or transitional adults aged 18 and older; 0.5-2.5 mm axial slices.
Who uses it?Intended users: Hospital networks and appropriately trained medical specialists.
What does the software produce?Output: A pop-up notification and compressed, low-quality, grayscale, unannotated preview labeled not for diagnostic use and for prioritization only when a suspected brain aneurysm at least 3.0 mm is flagged.
What is its most important limitation?Key limitation: Not a diagnostic device; inadequate field of view is excluded; the FDA testing input range was 0.5-2.5 mm axial slices; the preview has no finding marking and full PACS images must be reviewed.
Clinical takeaway
Clinical role: Adult contrast-enhanced brain CT triage for suspected brain aneurysm findings at least 3.0 mm.
Evidence takeaway
Evidence from the reviewed source record: FDA retrospective, blinded, multicenter pivotal study: 544 cases from six U.S. clinical sites, with ground truth from three senior board-certified radiologists and test data distinct from training. Primary sensitivity was 87.8% (95% CI 83.1-91.6) and specificity 91.6% (87.9-94.5). Secondary results included NPV 98.9%, PPV 47.6%, PLR 10.5, NLR 0.13, and mean time-to-notification 44.8 seconds (95% CI 41.4-48.2; n=241) versus 252 seconds for the predicate; the timing measure was calculated for true-positive cases.
Clinical details
What this tool is for
Start with the authorized purpose, then verify how it fits your service line and reading workflow.
Exact purpose
Adult contrast-enhanced brain CT triage for suspected brain aneurysm findings at least 3.0 mm.
A pop-up notification and compressed, low-quality, grayscale, unannotated preview labeled not for diagnostic use and for prioritization only when a suspected brain aneurysm at least 3.0 mm is flagged.
Not a diagnostic device; inadequate field of view is excluded; the FDA testing input range was 0.5-2.5 mm axial slices; the preview has no finding marking and full PACS images must be reviewed.
The FDA listing establishes the regulatory identity. It does not by itself establish local workflow fit, pricing, security, or performance in your environment.
Use these fields to structure a vendor demo, security review, and implementation estimate.
Integration
Linux-based cloud server receives filtered DICOM through an image communication platform and sends results to a desktop feed/non-diagnostic viewer for review of the original PACS images; exact current interfaces and versions are not established.
The reviewed sources do not establish the current exact-release hosting topology, data flow, region, tenancy, or disaster-recovery configuration.
Security and privacy
Vendor documentation pending
Vendor confirmation
Exact FDA submission
Checked 2026-09-08
Exact-release security controls, data retention, hosting boundaries, and scoped assurance documentation require vendor confirmation.
Training and support
Vendor documentation pending
Vendor confirmation
Exact FDA submission
Checked 2026-09-08
Current training prerequisites, competency checks, and support commitments for the exact configuration require vendor confirmation.
Monitoring and change control
Vendor documentation pending
Vendor confirmation
Exact FDA submission
Checked 2026-09-08
Current drift, quality, uptime, alert, escalation, and incident-response commitments for the exact configuration require vendor confirmation.
ACR exact-submission catalog context
ACR AI Central provides an exact-submission model card for BriefCase-Triage; FDA labeling remains controlling for clinical use, limitations, and performance.
Metrics are shown only when they are tied to a source, endpoint, population, and tested product version. Candidate literature without exact product and version linkage is not shown as product evidence.
Evidence summary
FDA retrospective, blinded, multicenter pivotal study: 544 cases from six U.S. clinical sites, with ground truth from three senior board-certified radiologists and test data distinct from training. Primary sensitivity was 87.8% (95% CI 83.1-91.6) and specificity 91.6% (87.9-94.5). Secondary results included NPV 98.9%, PPV 47.6%, PLR 10.5, NLR 0.13, and mean time-to-notification 44.8 seconds (95% CI 41.4-48.2; n=241) versus 252 seconds for the predicate; the timing measure was calculated for true-positive cases.
No contextualized exact-version metric has completed evidence review. Regulatory-document values, when available, are shown above with their limitations.
BriefCase-Triage Brain Aneurysm regulatory performance study summary
DesignStand-Alone Performance
PopulationAdult
Scopeexact submission
Tested version2
Samplen=544
Sites6
IndependenceIndependence not established
K251195
ACR AI Central summarizes the regulatory study; consult the exact FDA materials before comparative use.
These are common procurement questions; unknown values remain visible until a source supports them.
Pricing and total cost
Vendor documentation pending
Vendor confirmation
Exact FDA submission
Checked 2026-09-08
No public price or quote for the exact K251195 configuration was established in this review.
Reimbursement and coding
Not established in reviewed sources
Reviewed sources checked
Exact FDA submission
Checked 2026-09-08
No exact-product payer policy, coding instruction, or payment determination was established; eligibility must be evaluated by payer, site of service, and use case.
Safety and lifecycle
Postmarket record
Recall and adverse-event records are shown only after product matching. Adverse-event reports do not establish incidence or causality.
Postmarket safety review
The exact-identifier FDA recall query returned no native recall record for K251195. This limited result does not establish absence of recalls or other safety information and does not cover later versions, family records, MAUDE reports, corrections, or field notices.
Verify deployment and data flow: The reviewed sources do not establish the current exact-release hosting topology, data flow, region, tenancy, or disaster-recovery configuration.
Verify security and privacy controls: Exact-release security controls, data retention, hosting boundaries, and scoped assurance documentation require vendor confirmation.
Verify training: Current training prerequisites, competency checks, and support commitments for the exact configuration require vendor confirmation.
Verify pricing and total cost: No public price or quote for the exact K251195 configuration was established in this review.
Verify reimbursement and coding relevance: No exact-product payer policy, coding instruction, or payment determination was established; eligibility must be evaluated by payer, site of service, and use case.
Verify local validation and lifecycle monitoring: Current drift, quality, uptime, alert, escalation, and incident-response commitments for the exact configuration require vendor confirmation.
This audit distinguishes completed source review from fields that have not yet been researched.
Exact FDA record reviewedStatus
2026-09-19Last searched
23Fields reviewed
9Source classes checked
0Screened PubMed leads
0Screened trial leads
0Unreviewed FDA recall leads
The refreshed discovery snapshot contains no PubMed or ClinicalTrials.gov candidates; no external evidence was promoted. The current discovery snapshot contains 0 PubMed and 0 ClinicalTrials.gov candidate records; its dated, count-matched human screening remains current. Unlinked candidates remain quarantined. Native FDA recall identifiers produced 0 postmarket candidate records; 0 have been reviewed (0 published, 0 rejected) and 0 remain unreviewed.
Candidate leads were screened against the exact product and tested version. Unlinked records remain quarantined.
Source classes: fda ai list, acr ai central product, fda decision summary, fda device recall, literature index, trial registry, pubmed, clinical trials, openfda device recall
Sources & history
How this profile was documented
Open the ledger for source dates, scope, and research-record updates.
View source ledger and history7 sources - 3 history items
Annalise Enterprise prioritizes and notifies trained CT clinicians of suspected acute infarct on non-contrast brain CT for adults; it is a study-level, non-localizing worklist aid...
Methinks CTA Stroke analyzes acute-setting brain CT angiography in adults over 21 with suspected stroke for suspected large-vessel occlusion in the terminal ICA, MCA-M1, or MCA-M2...
Rapid CTA 360 analyzes adult head CTA DICOM images to flag suspected large- and medium-vessel occlusion in specified intracranial and vertebral segments and notify trained...
Methinks NCCT Stroke analyzes adult non-contrast head CT to flag suspected intracranial hemorrhage and suspected large-vessel occlusion of the ICA, MCA-M1, or MCA-M2 for parallel...