FDA-cleared profile

BriefCase-Triage

Aidoc Medical, Ltd.

Briefcase-Triage is a radiological computer- aided triage and notification software indicated for use in the analysis of CTPA images, in adults or transitional adolescents aged 18 and older. The device is intended to assist hospital networks and appropriately trained medical specialists in workflow triage by flagging and communicating suspected positive cases of Pulmonary Embolism (PE) pathologies. Briefcase-Triage uses an artificial intelligence algorithm to analyze images and highlight cases with detected findings in parallel to the ongoing standard of care image interpretation. The user is presented with notifications for cases with suspected PE findings. Notifications include compressed preview images that are meant for informational purposes only and not intended for diagnostic use beyond notification. The device does not alter the original medical image and is not intended to be used as a diagnostic device. The results of Briefcase-Triage are intended to be used in conjunction with other patient information and based on their professional judgment, to assist with triage/prioritization of medical images. Notified clinicians are responsible for viewing full images per the standard of care.

Evidence status: each field shows source quality, applicability, and review date. Research pending, information not established in reviewed sources, and vendor documentation pending are distinct outcomes.

Clinical fit

What this tool is for

Start with the authorized purpose, then verify how it fits your service line and reading workflow.

Exact purpose
Briefcase-Triage is a radiological computer- aided triage and notification software indicated for use in the analysis of CTPA images, in adults or transitional adolescents aged 18 and older. The device is intended to assist hospital networks and appropriately trained medical specialists in workflow triage by flagging and communicating suspected positive cases of Pulmonary Embolism (PE) pathologies. Briefcase-Triage uses an artificial intelligence algorithm to analyze images and highlight cases with detected findings in parallel to the ongoing standard of care image interpretation. The user is presented with notifications for cases with suspected PE findings. Notifications include compressed preview images that are meant for informational purposes only and not intended for diagnostic use beyond notification. The device does not alter the original medical image and is not intended to be used as a diagnostic device. The results of Briefcase-Triage are intended to be used in conjunction with other patient information and based on their professional judgment, to assist with triage/prioritization of medical images. Notified clinicians are responsible for viewing full images per the standard of care.
FDA source Exact FDA submission Checked 2026-08-31

Clinical-use display mirrors the best exact-submission purpose source because the reviewed FDA packet did not provide a more specific usable abstraction.

Intended users
Hospital networks and appropriately trained medical specialists
Public source Exact FDA submission Checked 2026-09-01

Intended-user text reported in the exact-submission ACR model card.

Care setting and population
Adult
Public source Exact FDA submission Checked 2026-09-01

Patient-population text reported in the exact-submission ACR model card; institutional setting may still require vendor confirmation.

Workflow role
Triage or notification support
Public source Exact FDA submission Checked 2026-08-31

Conservative normalization of explicit wording in an exact-submission source.

Required input
CT/CTA images or data involving Chest/Lung; consult the FDA labeling for exact protocol, series, and quality requirements.
Public source Exact FDA submission Checked 2026-08-31

Conservative normalization of explicit wording in an exact-submission source.

Output and human action
The AI algorithm analyzes CTPA images and flags suspected positive cases of Pulmonary Embolism (PE). When a suspected PE case is detected, the user receives a pop-up notification and is presented with a compressed, low-quality, grayscale preview image captioned 'not for diagnostic use, for prioritization only.' The output facilitates worklist prioritization/triage. No markings are placed on the findings in the preview image. The device does not provide a diagnostic output.
Public source Exact FDA submission Checked 2026-09-01

Clinical output reported in the exact-submission ACR model card.

Limitations
Exclusion criteria: All studies that are technically inadequate, including studies with motion artifacts, severe metal artifacts, sub-optimal bolus timing or an inadequate field of view.
Public source Exact FDA submission Checked 2026-09-01

Limitations and supported-acquisition details reported in the exact-submission ACR model card.

Regulatory identity

FDA record and catalog context

The FDA listing establishes the regulatory identity. It does not by itself establish local workflow fit, pricing, security, or performance in your environment.

FDA submission
K241727
FDA source Exact FDA submission Checked 2026-08-31
Modality
CT/CTA
FDA source Exact FDA submission Checked 2026-08-31
Anatomy
Chest/Lung
Public source Exact FDA submission Checked 2026-09-01

Anatomy normalized from explicit exact-submission ACR model-card wording.

Clearance type
510(k)
FDA source Exact FDA submission Checked 2026-08-31
Decision date
2024-07-12
FDA source Exact FDA submission Checked 2026-08-31
FDA status
FDA-cleared
FDA source Exact FDA submission Checked 2026-08-31

Implementation

Questions for IT, informatics, and operations

Use these fields to structure a vendor demo, security review, and implementation estimate.

Integration
Standards-based DICOM/PACS integration was identified in the FDA submission materials; compatibility with a specific PACS, RIS, EHR, or orchestrator requires confirmation.
Public source Exact FDA submission Checked 2026-08-13

Normalized from the prior exact-submission review. Confirm interface versions and local compatibility during technical evaluation.

Deployment and data flow
On-cloud
Public source Exact FDA submission Checked 2026-08-13

Deployment category preserved from the prior exact-submission review; hosting region, data flow, and current commercial configuration still require vendor confirmation.

Security and privacy
Vendor documentation pending
Vendor confirmation Exact FDA submission Checked 2026-09-09

Exact-release security controls, data retention, hosting boundaries, and scoped assurance documentation require vendor confirmation.

Training and support
Vendor documentation pending
Vendor confirmation Exact FDA submission Checked 2026-09-09

Current training prerequisites, competency checks, and support commitments for the exact configuration require vendor confirmation.

Monitoring and change control
Vendor documentation pending
Vendor confirmation Exact FDA submission Checked 2026-09-09

Current drift, quality, uptime, alert, escalation, and incident-response commitments for the exact configuration require vendor confirmation.

ACR exact-submission catalog context

ACR AI Central provides an exact-submission model card for BriefCase-Triage; FDA labeling remains controlling for clinical use, limitations, and performance.

exact submission · checked 2026-09-09

Evidence

Performance evidence

Metrics are shown only when they are tied to a source, endpoint, population, and tested product version.

Evidence summary
Study type: Stand-Alone Performance. Cases: 499. Sites: 6. Reference standard: Interpretation by Reviewing Clinician. Reported sensitivity: 94.39% (95% CI: 90.41%, 97.07%). Reported specificity: 94.39% (95% CI: 91.04%, 96.67%)
Public source Exact FDA submission Checked 2026-09-01

Structured study metadata from the exact-submission ACR model card; this is not an independent evidence synthesis.

Reported sensitivity
94.39% (95% CI: 90.41%, 97.07%)
Public source Exact FDA submission Checked 2026-09-01

Model sensitivity reported by ACR AI Central. Review endpoint, threshold, study population, and tested version before comparison.

Reported specificity
94.39% (95% CI: 91.04%, 96.67%)
Public source Exact FDA submission Checked 2026-09-01

Model specificity reported by ACR AI Central. Review endpoint, threshold, study population, and tested version before comparison.

No contextualized exact-version metric has completed evidence review. Regulatory-document values, when available, are shown above with their limitations.

BriefCase-Pulmonary Embolism Triage regulatory performance study summary

Stand-Alone Performance · Adult

exact submission · Tested version: 3 · n=499 · 6 sites · Independence not established

K241727

ACR AI Central summarizes the regulatory study; consult the exact FDA materials before comparative use.

Economics and lifecycle

Budget and ongoing governance

These are common procurement questions; unknown values remain visible until a source supports them.

Pricing and total cost
Vendor documentation pending
Vendor confirmation Exact FDA submission Checked 2026-09-09

No public price or quote for the exact K241727 configuration was established in this review.

Reimbursement and coding
Not established in reviewed sources
Reviewed sources checked Exact FDA submission Checked 2026-09-09

No exact-product payer policy, coding instruction, or payment determination was established; eligibility must be evaluated by payer, site of service, and use case.

Safety and lifecycle

Postmarket record

Recall and adverse-event records are shown only after product matching. Adverse-event reports do not establish incidence or causality.

Postmarket safety review
The exact-identifier FDA recall query returned no native recall record for K241727. This limited result does not establish absence of recalls or other safety information and does not cover later versions, family records, MAUDE reports, corrections, or field notices.
Public source Exact FDA submission Checked 2026-09-09

Buyer worksheet

Open questions to take to the vendor

Open evaluation checklist

Research record

What has been checked

This audit distinguishes completed source review from fields that have not yet been researched.

Automated sources checkedStatus
2026-09-09Last searched
24Fields reviewed
9Source classes checked
0Unreviewed PubMed leads
0Unreviewed trial leads
0Unreviewed FDA recall leads

Exact-submission ACR model-card fields were normalized under the current provenance rules; vendor and independent-study confirmation remain distinct. Exact FDA and recall packets were prepared and identity matched, but no new clinical or performance claim was promoted in the conservative fallback. Existing exact-submission facts retain their original source status and applicability; candidate literature remains quarantined. Automated exact-name discovery found 0 PubMed and 0 ClinicalTrials.gov candidate records. Candidates require human product and version matching; zero candidates is not evidence that no studies exist. Native FDA recall identifiers produced 0 postmarket candidate records; 0 have been reviewed (0 published, 0 rejected) and 0 remain unreviewed.

Candidate leads remain unpublished until a human confirms the exact product and tested version.

Source classes: fda ai list, fda decision summary, acr ai central product, fda device recall, literature index, trial registry, pubmed, clinical trials, openfda device recall

Sources

Source ledger

Sources accessed through 2026-09-09.

Alternatives

Related tools to compare

FDA-cleared K213886

BriefCase

Aidoc Medical, Ltd.

BriefCase is a radiological computer aided triage and notification software indicated for use in the analysis of contrast-enhanced chest CTs (not dedicated CTPA protocol) in...

Modality
CT/CTA
Anatomy
Chest/Lung
Decision
2022-04-26
FDA-cleared K201020

BriefCase

Aidoc Medical, Ltd.

BriefCase analyzes contrast-enhanced chest CT for suspected pulmonary embolism and notifies or prioritizes the study in the labeled hospital or cloud worklist workflow; the output...

Modality
CT/CTA
Anatomy
Chest/Lung
Decision
2020-08-26