FDA-cleared profile

EchoMeasure

iCardio.ai

Authorized purpose: Process previously acquired DICOM-compliant cardiac ultrasound images and make automated cardiac measurements to support qualified cardiologists, sonographers, or other licensed healthcare practitioners in adult clinical decision-making.

Evidence status: each field states its source quality, applicability, and review date. Research pending, information not established, and vendor documentation pending remain distinct outcomes.

Product overview

Start with the essentials

Authorized purpose: Process previously acquired DICOM-compliant cardiac ultrasound images and make automated cardiac measurements to support qualified cardiologists, sonographers, or other licensed healthcare practitioners in adult clinical decision-making.

Overview status: Source-reviewed overview

Clinical takeaway

Clinical role: Process previously acquired DICOM-compliant cardiac ultrasound images and make automated cardiac measurements to support qualified cardiologists, sonographers, or other licensed healthcare practitioners in adult clinical decision-making.

Evidence takeaway

Evidence from the reviewed source record: FDA retrospective standalone performance testing used 200 distinct patients from two independent U.S. clinical sites, with one selected DICOM view per case. Ground truth was the mean of three experienced U.S. cardiac sonographers. The study evaluated the bivariate linear regression coefficient slope (BLRSC) against the reference annotations; all predefined limits were met, with listed BLRSC point estimates ranging from 0.773 to 1.112. The FDA summary also describes median absolute error, median percent error, Pearson and Spearman correlation, and Individual Equivalence Coefficient analyses, but does not report sensitivity or specificity. No data from the sites were used for training or tuning.

Clinical details

What this tool is for

Start with the authorized purpose, then verify how it fits your service line and reading workflow.

Exact purpose
Process previously acquired DICOM-compliant cardiac ultrasound images and make automated cardiac measurements to support qualified cardiologists, sonographers, or other licensed healthcare practitioners in adult clinical decision-making.
  • FDA source
  • Exact FDA submission
  • Checked 2026-09-08
Intended users
Qualified cardiologists, sonographers, accredited echocardiographers, or other licensed professional healthcare practitioners.
  • FDA source
  • Exact FDA submission
  • Checked 2026-09-08
Care setting and population
Adult clinical echocardiography workflow; the FDA packet permits secure cloud-server or on-premise-server deployment but does not name a specific facility type.
  • FDA source
  • Exact FDA submission
  • Checked 2026-09-08
Workflow role
Post-acquisition image eligibility and quality control followed by automated measurement support; the reviewing clinician can accept, reject, edit, or ignore the output and review the generated report.
  • FDA source
  • Exact FDA submission
  • Checked 2026-09-08
Required input
Previously acquired DICOM-compliant transthoracic cardiac ultrasound images, including appropriate PLAX, A2C, or A4C views with acceptable quality and identifiable end-diastolic and end-systolic frames.
  • FDA source
  • Exact FDA submission
  • Checked 2026-09-08
Output and human action
Automated measurements of left-ventricular volume and diameter, right-ventricular diameter, posterior-wall thickness, aortic annulus, LV outflow tract, sinus of Valsalva, sinotubular junction, left-atrium dimension, and interventricular septal thickness; results are viewable in a browser interface, report, or PDF and are intended for third-party software or hardware consumption.
  • FDA source
  • Exact FDA submission
  • Checked 2026-09-08
Limitations
Indicated for adults and qualified clinical users. The output supports review and clinical decision-making and remains subject to clinician confirmation; it is not an independent diagnostic decision. The FDA standalone study used one selected DICOM view per case from GE and Teratech systems, so broader protocol or vendor performance is not established by this packet.
  • FDA source
  • Exact FDA submission
  • Checked 2026-09-08

Regulatory identity

FDA record and catalog context

The FDA listing establishes the regulatory identity. It does not by itself establish local workflow fit, pricing, security, or performance in your environment.

FDA submission
K241430
  • FDA source
  • Exact FDA submission
  • Checked 2026-08-31
Modality
Ultrasound
  • FDA source
  • Exact FDA submission
  • Checked 2026-09-08
Anatomy
Heart and cardiovascular structures
  • FDA source
  • Exact FDA submission
  • Checked 2026-09-08
Clearance type
510(k)
  • FDA source
  • Exact FDA submission
  • Checked 2026-08-31
Decision date
2024-10-10
  • FDA source
  • Exact FDA submission
  • Checked 2026-08-31
FDA status
FDA-cleared
  • FDA source
  • Exact FDA submission
  • Checked 2026-08-31

Implementation

Questions for IT, informatics, and operations

Use these fields to structure a vendor demo, security review, and implementation estimate.

Integration
Receives DICOM inputs and can be deployed on a secure cloud server or on-premise server; output can be consumed by third-party software or hardware, viewed in a native browser interface, and downloaded as PDF. Specific PACS, RIS, EHR, interface versions, and local compatibility are not established.
  • FDA source
  • Exact FDA submission
  • Checked 2026-09-08
Deployment and data flow
Both
  • Public source
  • Exact FDA submission
  • Checked 2026-08-13

Deployment category preserved from the prior exact-submission review; hosting region, data flow, and current commercial configuration still require vendor confirmation.

Security and privacy
Vendor documentation pending
  • Vendor confirmation
  • Exact FDA submission
  • Checked 2026-09-08

Exact-release security controls, data retention, hosting boundaries, and scoped assurance documentation require vendor confirmation.

Training and support
Vendor documentation pending
  • Vendor confirmation
  • Exact FDA submission
  • Checked 2026-09-08

Current training prerequisites, competency checks, and support commitments for the exact configuration require vendor confirmation.

Monitoring and change control
Vendor documentation pending
  • Vendor confirmation
  • Exact FDA submission
  • Checked 2026-09-08

Current drift, quality, uptime, alert, escalation, and incident-response commitments for the exact configuration require vendor confirmation.

Input or output interoperability

DICOM is explicitly referenced in the described input, output, or workflow.

exact submission · checked 2026-09-01

The model card does not establish every supported DICOM object, transfer method, or local interface.

ACR exact-submission catalog context

ACR AI Central provides an exact-submission model card for EchoMeasure; FDA labeling remains controlling for clinical use, limitations, and performance.

exact submission · checked 2026-09-08

Evidence

Performance evidence

Metrics are shown only when they are tied to a source, endpoint, population, and tested product version. Candidate literature without exact product and version linkage is not shown as product evidence.

Evidence summary
FDA retrospective standalone performance testing used 200 distinct patients from two independent U.S. clinical sites, with one selected DICOM view per case. Ground truth was the mean of three experienced U.S. cardiac sonographers. The study evaluated the bivariate linear regression coefficient slope (BLRSC) against the reference annotations; all predefined limits were met, with listed BLRSC point estimates ranging from 0.773 to 1.112. The FDA summary also describes median absolute error, median percent error, Pearson and Spearman correlation, and Individual Equivalence Coefficient analyses, but does not report sensitivity or specificity. No data from the sites were used for training or tuning.
  • FDA source
  • Exact FDA submission
  • Checked 2026-09-08
Reported sensitivity
Research pending
  • Needs research
  • Exact FDA submission
  • Checked 2026-08-31

This field has not been curated yet.

Reported specificity
Research pending
  • Needs research
  • Exact FDA submission
  • Checked 2026-08-31

This field has not been curated yet.

No contextualized exact-version metric has completed evidence review. Regulatory-document values, when available, are shown above with their limitations.

EchoMeasure regulatory performance study summary

  • DesignStand-Alone Performance
  • PopulationAdult
  • Scopeexact submission
  • Tested versionExact product version not reported; regulatory study summarized for FDA submission K241430
  • Samplen=200
  • IndependenceIndependence not established

K241430

ACR AI Central summarizes the regulatory study; consult the exact FDA materials before comparative use.

Costs and setup

Budget and ongoing governance

These are common procurement questions; unknown values remain visible until a source supports them.

Pricing and total cost
Vendor documentation pending
  • Vendor confirmation
  • Exact FDA submission
  • Checked 2026-09-08

No public price or quote for the exact K241430 configuration was established in this review.

Reimbursement and coding
Not established in reviewed sources
  • Reviewed sources checked
  • Exact FDA submission
  • Checked 2026-09-08

No exact-product payer policy, coding instruction, or payment determination was established; eligibility must be evaluated by payer, site of service, and use case.

Safety and lifecycle

Postmarket record

Recall and adverse-event records are shown only after product matching. Adverse-event reports do not establish incidence or causality.

Postmarket safety review
The exact-identifier FDA recall query returned no native recall record for K241430. This limited result does not establish absence of recalls or other safety information and does not cover later versions, family records, MAUDE reports, corrections, or field notices.
  • Public source
  • Exact FDA submission
  • Checked 2026-09-08

Buyer worksheet

Open questions to take to the vendor

Open evaluation checklist

Research record

What has been checked

This audit distinguishes completed source review from fields that have not yet been researched.

Exact FDA record reviewedStatus
2026-09-20Last searched
23Fields reviewed
9Source classes checked
0Screened PubMed leads
0Screened trial leads
0Unreviewed FDA recall leads

The refreshed discovery snapshot contains no PubMed or ClinicalTrials.gov candidates; no external evidence was promoted. The current discovery snapshot contains 0 PubMed and 0 ClinicalTrials.gov candidate records; its dated, count-matched human screening remains current. Unlinked candidates remain quarantined. Native FDA recall identifiers produced 0 postmarket candidate records; 0 have been reviewed (0 published, 0 rejected) and 0 remain unreviewed.

Candidate leads were screened against the exact product and tested version. Unlinked records remain quarantined.

Source classes: fda ai list, fda decision summary, acr ai central product, fda device recall, literature index, trial registry, pubmed, clinical trials, openfda device recall

Sources & history

How this profile was documented

Open the ledger for source dates, scope, and research-record updates.

View source ledger and history

Source ledger

  1. FDA K241430: EchoMeasure

    U.S. Food and Drug Administration - Published 2024-10-10 - Accessed 2026-09-08

    Scope: identity, clinicalUse, modality, anatomy, workflow, evidence, implementation

  2. Artificial Intelligence-Enabled Medical Devices

    U.S. Food and Drug Administration - Accessed 2026-08-31

    Scope: regulatoryIdentity, modalityContext

  3. EchoMeasure model card (K241430)

    American College of Radiology - Published 2026-08-17 - Accessed 2026-09-01

    Scope: intendedUsers, careSetting, output, evidenceSummary, integration, anatomy, evidenceStudies, implementationCapabilities

  4. PubMed biomedical literature index

    U.S. National Library of Medicine - Accessed 2026-09-01

    Scope: evidenceDiscovery

  5. ClinicalTrials.gov study registry

    U.S. National Library of Medicine - Accessed 2026-09-01

    Scope: evidenceDiscovery, studyStatus

  6. openFDA Device Recall API

    U.S. Food and Drug Administration - Accessed 2026-09-02

    Scope: recallDiscovery, nativeSubmissionMatching

  7. openFDA exact recall query for K241430

    U.S. Food and Drug Administration - Accessed 2026-09-08

    Scope: postmarketSafety

Research history

  1. K241430 FDA decision

    Regulatory record

    510(k)

  2. Source-review record updated

    Research record

    fda record reviewed

  3. Reader overview source-reviewed

    Editorial review

    Source-reviewed editorial overlay

Alternatives

Related tools to compare