Authorized purpose: Identify and localize listed dental findings, historical treatments, and normal anatomy on bitewing, periapical, and panoramic intraoral radiographs for patients aged 3 years and older, with indication-specific age and view limits; suspect dental-finding indications are adjunctive and diagnostic use is limited to dentists.
Evidence status: each field states its source quality, applicability, and review date. Research pending, information not established, and vendor documentation pending remain distinct outcomes.
Product overview
Start with the essentials
Authorized purpose: Identify and localize listed dental findings, historical treatments, and normal anatomy on bitewing, periapical, and panoramic intraoral radiographs for patients aged 3 years and older, with indication-specific age and view limits; suspect dental-finding indications are adjunctive and diagnostic use is limited to dentists.
Overview status: Source-reviewed overview
What does this software do?Authorized purpose: Identify and localize listed dental findings, historical treatments, and normal anatomy on bitewing, periapical, and panoramic intraoral radiographs for patients aged 3 years and older, with indication-specific age and view limits; suspect dental-finding indications are adjunctive and diagnostic use is limited to dentists.
Which images or clinical context are in scope?Modality: X-ray/Radiography Anatomy or clinical context: Dental/Maxillofacial (suspected findings, historical treatments, and normal anatomy) Input: Eligible bitewing, periapical, or panoramic intraoral radiographs from patients aged 3 years and older with primary, mixed, and/or permanent dentition, subject to indication-specific limits: some findings require age 12 or 22 and permanent dentition, and panoramic use is for historical-treatment and normal-anatomy indications.
Who uses it?Intended users: Trained dental professionals including dentists and dental hygienists; only dentists performing diagnostic activities should use suspect dental-finding indications.
What does the software produce?Output: For each indication, a binary present/absent result; when findings are present, the number by finding type and bounding-box coordinates, and when absent, a clear no-findings indication. Results cover all findings on one radiograph regardless of tooth count.
What is its most important limitation?Key limitation: Not a substitute for full patient evaluation or sole basis to make or confirm a diagnosis. Indication-specific gates apply: caries and many findings are tested on bitewing/periapical images from age 3, pulp stones require age 12 and permanent dentition, periapical radiolucency and furcation require age 22 and permanent dentition, and panoramic images are limited to the historical-treatment and normal-anatomy scopes. Historical-treatment and normal-anatomy outputs are not diagnostic aids. The FDA standalone study reports that caries specificity was the only suspect-finding specificity not to meet its standalone target, although the indication passed the clinical-study criteria.
Clinical takeaway
Clinical role: Identify and localize listed dental findings, historical treatments, and normal anatomy on bitewing, periapical, and panoramic intraoral radiographs for patients aged 3 years and older, with indication-specific age and view limits; suspect dental-finding indications are adjunctive and diagnostic use is limited to dentists.
Evidence takeaway
Evidence from the reviewed source record: FDA K232384 reports standalone testing on 1,445 radiographs from more than 35 US sites, ground-truthed by three US board-certified dentists across 17 sensor manufacturers, with all listed indications in scope. All historical-treatment and normal-anatomy indications met sensitivity/specificity criteria; all suspect dental findings met criteria except caries specificity, which still passed the clinical-study criteria. A separate clinical reader study used 378 radiographs from more than 25 US locations, 26 readers, and dentist labeling/adjudication; AFROC reader improvements included 4.3% for caries, 28.5% for attrition, and 11.5% for periapical radiolucency.
Clinical details
What this tool is for
Start with the authorized purpose, then verify how it fits your service line and reading workflow.
Exact purpose
Identify and localize listed dental findings, historical treatments, and normal anatomy on bitewing, periapical, and panoramic intraoral radiographs for patients aged 3 years and older, with indication-specific age and view limits; suspect dental-finding indications are adjunctive and diagnostic use is limited to dentists.
Trained dental professionals including dentists and dental hygienists; only dentists performing diagnostic activities should use suspect dental-finding indications.
Adjunct detection and localization for dental image review and practice operations, with indication-specific outputs for diagnostic suspect findings, historical treatments, and normal anatomy.
Eligible bitewing, periapical, or panoramic intraoral radiographs from patients aged 3 years and older with primary, mixed, and/or permanent dentition, subject to indication-specific limits: some findings require age 12 or 22 and permanent dentition, and panoramic use is for historical-treatment and normal-anatomy indications.
For each indication, a binary present/absent result; when findings are present, the number by finding type and bounding-box coordinates, and when absent, a clear no-findings indication. Results cover all findings on one radiograph regardless of tooth count.
Not a substitute for full patient evaluation or sole basis to make or confirm a diagnosis. Indication-specific gates apply: caries and many findings are tested on bitewing/periapical images from age 3, pulp stones require age 12 and permanent dentition, periapical radiolucency and furcation require age 22 and permanent dentition, and panoramic images are limited to the historical-treatment and normal-anatomy scopes. Historical-treatment and normal-anatomy outputs are not diagnostic aids. The FDA standalone study reports that caries specificity was the only suspect-finding specificity not to meet its standalone target, although the indication passed the clinical-study criteria.
The FDA listing establishes the regulatory identity. It does not by itself establish local workflow fit, pricing, security, or performance in your environment.
Use these fields to structure a vendor demo, security review, and implementation estimate.
Integration
Cloud-based Videa Dental Assist is accessed through an API behind a firewalled network and a dental image viewer; authenticated users upload eligible images and review returned bounding boxes and finding statuses. The FDA packet does not establish DICOM, PACS, RIS, EHR, or a specific production deployment.
The reviewed sources do not establish the current exact-release hosting topology, data flow, region, tenancy, or disaster-recovery configuration.
Security and privacy
Vendor documentation pending
Vendor confirmation
Exact FDA submission
Checked 2026-09-08
Exact-release security controls, data retention, hosting boundaries, and scoped assurance documentation require vendor confirmation.
Training and support
Vendor documentation pending
Vendor confirmation
Exact FDA submission
Checked 2026-09-08
Current training prerequisites, competency checks, and support commitments for the exact configuration require vendor confirmation.
Monitoring and change control
Vendor documentation pending
Vendor confirmation
Exact FDA submission
Checked 2026-09-08
Current drift, quality, uptime, alert, escalation, and incident-response commitments for the exact configuration require vendor confirmation.
ACR exact-submission catalog context
ACR AI Central provides an exact-submission model card for Videa Dental Assist; FDA labeling remains controlling for clinical use, limitations, and performance.
Metrics are shown only when they are tied to a source, endpoint, population, and tested product version. Candidate literature without exact product and version linkage is not shown as product evidence.
Evidence summary
FDA K232384 reports standalone testing on 1,445 radiographs from more than 35 US sites, ground-truthed by three US board-certified dentists across 17 sensor manufacturers, with all listed indications in scope. All historical-treatment and normal-anatomy indications met sensitivity/specificity criteria; all suspect dental findings met criteria except caries specificity, which still passed the clinical-study criteria. A separate clinical reader study used 378 radiographs from more than 25 US locations, 26 readers, and dentist labeling/adjudication; AFROC reader improvements included 4.3% for caries, 28.5% for attrition, and 11.5% for periapical radiolucency.
No contextualized exact-version metric has completed evidence review. Regulatory-document values, when available, are shown above with their limitations.
Videa Dental Assist regulatory performance study summary
DesignStand-alone performance and reader study (ACR AI Central category)
PopulationAdult and Pediatric
Scopeexact submission
Tested versionExact product version not reported; regulatory study summarized for FDA submission K232384
Samplen=1445
Sites35
IndependenceIndependence not established
K232384
ACR AI Central summarizes the regulatory study; consult the exact FDA materials before comparative use.
These are common procurement questions; unknown values remain visible until a source supports them.
Pricing and total cost
Vendor documentation pending
Vendor confirmation
Exact FDA submission
Checked 2026-09-08
No public price or quote for the exact K232384 configuration was established in this review.
Reimbursement and coding
Not established in reviewed sources
Reviewed sources checked
Exact FDA submission
Checked 2026-09-08
No exact-product payer policy, coding instruction, or payment determination was established; eligibility must be evaluated by payer, site of service, and use case.
Safety and lifecycle
Postmarket record
Recall and adverse-event records are shown only after product matching. Adverse-event reports do not establish incidence or causality.
Postmarket safety review
The exact-identifier FDA recall query returned no native recall record for K232384. This limited result does not establish absence of recalls or other safety information and does not cover later versions, family records, MAUDE reports, corrections, or field notices.
Verify deployment and data flow: The reviewed sources do not establish the current exact-release hosting topology, data flow, region, tenancy, or disaster-recovery configuration.
Verify security and privacy controls: Exact-release security controls, data retention, hosting boundaries, and scoped assurance documentation require vendor confirmation.
Verify training: Current training prerequisites, competency checks, and support commitments for the exact configuration require vendor confirmation.
Verify pricing and total cost: No public price or quote for the exact K232384 configuration was established in this review.
Verify reimbursement and coding relevance: No exact-product payer policy, coding instruction, or payment determination was established; eligibility must be evaluated by payer, site of service, and use case.
Verify local validation and lifecycle monitoring: Current drift, quality, uptime, alert, escalation, and incident-response commitments for the exact configuration require vendor confirmation.
This audit distinguishes completed source review from fields that have not yet been researched.
Exact FDA record reviewedStatus
2026-09-20Last searched
21Fields reviewed
9Source classes checked
0Screened PubMed leads
0Screened trial leads
0Unreviewed FDA recall leads
The refreshed discovery snapshot contains no PubMed or ClinicalTrials.gov candidates; no external evidence was promoted. The current discovery snapshot contains 0 PubMed and 0 ClinicalTrials.gov candidate records; its dated, count-matched human screening remains current. Unlinked candidates remain quarantined. Native FDA recall identifiers produced 0 postmarket candidate records; 0 have been reviewed (0 published, 0 rejected) and 0 remain unreviewed.
Candidate leads were screened against the exact product and tested version. Unlinked records remain quarantined.
Source classes: fda ai list, fda decision summary, acr ai central product, fda device recall, literature index, trial registry, pubmed, clinical trials, openfda device recall
Sources & history
How this profile was documented
Open the ledger for source dates, scope, and research-record updates.
View source ledger and history7 sources - 3 history items
Assist trained professionals in assessing radiographic knee osteoarthritis and its sclerosis, joint-space-narrowing, and osteophyte features on standing fixed-flexion knee...
Overjet Iris is a web-based dental PACS for storing, viewing, and supporting image-quality review of two-dimensional intraoral radiographs, panoramic images, and color photographs.
Second Opinion Panoramic is an automated image-processing aid that identifies and marks regions of interest for caries, periapical radiolucency, and impacted third molars on...
Modality
X-ray/Radiography
Anatomy
Permanent teeth; caries, periapical radiolucency, and impacted third molars
Analyzes bitewing, periapical, and panoramic intraoral radiographs from patients aged 3 years and older to identify and localize specified suspected dental findings, historical...