FDA-cleared profile

uPMR 790

Shanghai United Imaging Healthcare Co., Ltd.

Authorized purpose: The uPMR 790 combines MR and PET devices to provide registered and fused high-resolution physiologic and anatomic information acquired simultaneously and isocentrically. The FDA indication describes independent MR and PET functionality, MR images of the head, body, and extremities, PET radiopharmaceutical distribution, MR-based attenuation correction, and fused PET/MR reference.

Evidence status: each field states its source quality, applicability, and review date. Research pending, information not established, and vendor documentation pending remain distinct outcomes.

Product overview

Start with the essentials

Authorized purpose: The uPMR 790 combines MR and PET devices to provide registered and fused high-resolution physiologic and anatomic information acquired simultaneously and isocentrically. The FDA indication describes independent MR and PET functionality, MR images of the head, body, and extremities, PET radiopharmaceutical distribution, MR-based attenuation correction, and fused PET/MR reference.

Overview status: Source-reviewed overview

Clinical takeaway

Clinical role: The uPMR 790 combines MR and PET devices to provide registered and fused high-resolution physiologic and anatomic information acquired simultaneously and isocentrically. The FDA indication describes independent MR and PET functionality, MR images of the head, body, and extremities, PET radiopharmaceutical distribution, MR-based attenuation correction, and fused PET/MR reference.

Evidence takeaway

Evidence from the reviewed source record: The exact FDA 510(k) decision material for K234154 identifies uPMR 790 and describes the indicated use summarized in this dossier. It is regulatory evidence for the exact submission, not independent clinical validation. No performance or outcome claim is promoted without exact product and version linkage.

Clinical details

What this tool is for

Start with the authorized purpose, then verify how it fits your service line and reading workflow.

Exact purpose
The uPMR 790 combines MR and PET devices to provide registered and fused high-resolution physiologic and anatomic information acquired simultaneously and isocentrically. The FDA indication describes independent MR and PET functionality, MR images of the head, body, and extremities, PET radiopharmaceutical distribution, MR-based attenuation correction, and fused PET/MR reference.
  • FDA source
  • Exact FDA submission
  • Checked 2026-09-04
Intended users
Qualified MRI, PET, and nuclear-medicine technologists and interpreting physicians.
  • FDA source
  • Exact FDA submission
  • Checked 2026-09-04
Care setting and population
Hospital or outpatient hybrid-imaging departments with the exact MR, PET, safety, and radiopharmaceutical configuration.
  • FDA source
  • Exact FDA submission
  • Checked 2026-09-04
Workflow role
Independent and fused MR/PET acquisition, attenuation correction, registration, display, and professional interpretation.
  • FDA source
  • Exact FDA submission
  • Checked 2026-09-04
Required input
Supported MR signal data, PET emission data, contrast or radiopharmaceutical inputs, patient information, and acquisition metadata.
  • FDA source
  • Exact FDA submission
  • Checked 2026-09-04
Output and human action
MR, PET, fused, registered, and attenuation-correction images for qualified professional review.
  • FDA source
  • Exact FDA submission
  • Checked 2026-09-04
Limitations
Radiopharmaceutical, MR safety, contrast, acquisition, attenuation-correction, patient, anatomy, and interpretation requirements remain modality- and configuration-specific. Fusion does not replace qualified clinical interpretation.
  • FDA source
  • Exact FDA submission
  • Checked 2026-09-04

Regulatory identity

FDA record and catalog context

The FDA listing establishes the regulatory identity. It does not by itself establish local workflow fit, pricing, security, or performance in your environment.

FDA submission
K234154
  • FDA source
  • Exact FDA submission
  • Checked 2026-08-31
Modality
PET/SPECT/Nuclear Medicine
  • FDA source
  • Exact FDA submission
  • Checked 2026-09-04
Anatomy
Head, body, and extremities represented in fused PET/MR studies
  • FDA source
  • Exact FDA submission
  • Checked 2026-09-04
Clearance type
510(k)
  • FDA source
  • Exact FDA submission
  • Checked 2026-08-31
Decision date
2024-05-24
  • FDA source
  • Exact FDA submission
  • Checked 2026-08-31
FDA status
FDA-cleared
  • FDA source
  • Exact FDA submission
  • Checked 2026-08-31

Implementation

Questions for IT, informatics, and operations

Use these fields to structure a vendor demo, security review, and implementation estimate.

Integration
Standards-based DICOM/PACS integration was identified in the FDA submission materials; compatibility with a specific PACS, RIS, EHR, or orchestrator requires confirmation.
  • Public source
  • Exact FDA submission
  • Checked 2026-08-13

Normalized from the prior exact-submission review. Confirm interface versions and local compatibility during technical evaluation.

Deployment and data flow
Not established in reviewed sources
  • Reviewed sources checked
  • Exact FDA submission
  • Checked 2026-09-04

The exact FDA decision material does not establish the complete deployment topology, hosting responsibility, availability, upgrade path, or service contract.

Security and privacy
Not established in reviewed sources
  • Reviewed sources checked
  • Exact FDA submission
  • Checked 2026-09-04

Public materials reviewed for this exact release do not establish the complete security posture. Request data-flow, identity, audit, encryption, retention, remote-access, vulnerability-management, backup, and incident-response evidence.

Training and support
Only qualified mri, pet, and nuclear-medicine technologists and interpreting physicians should operate or interpret this product. Local onboarding should cover the exact release, supported population, limitations, failure examples, escalation, downtime, and competency documentation.
  • FDA source
  • Exact FDA submission
  • Checked 2026-09-04
Monitoring and change control
Monitor by exact hardware, software, model, algorithm, reconstruction, or configuration version; patient population; anatomy; protocol; operator; input quality; output edits or overrides; failed studies; repeat acquisition or rework; downstream impact; downtime; incidents; recalls; and updates. Track these product-specific limits: Radiopharmaceutical, MR safety, contrast, acquisition, attenuation-correction, patient, anatomy, and interpretation requirements remain modality- and configuration-specific. Fusion does not replace qualified clinical interpretation.
  • FDA source
  • Exact FDA submission
  • Checked 2026-09-04

Release and scope verification

Map installed model, build, options, population, anatomy, inputs, outputs, and enabled functions to K234154 before acceptance. Later family features are not evidence for this exact submission.

exact submission · checked 2026-09-04

Interoperability acceptance

The exact FDA material does not establish a complete interoperability contract. Establish and test supported input, output, identity, routing, archive, and downtime behavior locally.

exact submission · checked 2026-09-04

Deployment and security qualification

The exact FDA material does not establish hosting, deployment topology, availability, upgrade path, or service responsibility. Obtain site-specific evidence before procurement.

exact submission · checked 2026-09-04

Clinical acceptance

Use a signed local test set for the supported population and workflow. Include common and difficult cases, exclusions, acquisition variation, failed or low-quality inputs, reviewer overrides, and downstream effects. Radiopharmaceutical, MR safety, contrast, acquisition, attenuation-correction, patient, anatomy, and interpretation requirements remain modality- and configuration-specific. Fusion does not replace qualified clinical interpretation.

exact submission · checked 2026-09-04

Define stop-use, escalation, rollback, and revalidation triggers before production use.

Economic evaluation

Model capital and recurring cost against net staff time after review, throughput, repeat imaging or rework, room time, consumables, infrastructure, training, service, downtime, upgrade, and replacement costs. No exact-product price was found.

product family · checked 2026-09-04

Lifecycle monitoring

Monitor by exact hardware, software, model, algorithm, reconstruction, or configuration version; patient population; anatomy; protocol; operator; input quality; output edits or overrides; failed studies; repeat acquisition or rework; downstream impact; downtime; incidents; recalls; and updates. Track these product-specific limits: Radiopharmaceutical, MR safety, contrast, acquisition, attenuation-correction, patient, anatomy, and interpretation requirements remain modality- and configuration-specific. Fusion does not replace qualified clinical interpretation.

exact submission · checked 2026-09-04

Revalidate after material software, hardware, model, protocol, interface, or clinical-policy changes.

Evidence

Performance evidence

Metrics are shown only when they are tied to a source, endpoint, population, and tested product version. Candidate literature without exact product and version linkage is not shown as product evidence.

Evidence summary
The exact FDA 510(k) decision material for K234154 identifies uPMR 790 and describes the indicated use summarized in this dossier. It is regulatory evidence for the exact submission, not independent clinical validation. No performance or outcome claim is promoted without exact product and version linkage.
  • FDA source
  • Exact FDA submission
  • Checked 2026-09-04
Reported sensitivity
Not applicable
  • Not applicable
  • Not applicable
  • Checked 2026-09-04

Sensitivity is not a product-wide endpoint for this system or software function. Compare only an exact endpoint, threshold, population, version, and source if later verified.

Reported specificity
Not applicable
  • Not applicable
  • Not applicable
  • Checked 2026-09-04

Specificity is not a product-wide endpoint for this system or software function. Compare only an exact endpoint, threshold, population, version, and source if later verified.

No contextualized exact-version metric has completed evidence review. Regulatory-document values, when available, are shown above with their limitations.

K234154 FDA decision evidence for uPMR 790

  • DesignFDA 510(k) substantial-equivalence review of the exact submission, device description, indications, and verification or validation documentation.
  • PopulationHead, body, and extremities represented in fused PET/MR studies
  • Scopeexact submission
  • Tested versionuPMR 790
  • IndependenceSponsor or vendor study

K234154

The FDA decision material is manufacturer-submitted regulatory evidence. It is not independent clinical validation, and local technical, clinical, privacy, security, and workflow acceptance remains necessary.

Costs and setup

Budget and ongoing governance

These are common procurement questions; unknown values remain visible until a source supports them.

Pricing and total cost
Not established in reviewed sources
  • Reviewed sources checked
  • Exact FDA submission
  • Checked 2026-09-04

No public list price for the exact cleared or approved configuration was found. Obtain a written quote separating hardware or license basis, implementation, interfaces, infrastructure, training, service, upgrades, renewal, consumables, and exit costs.

Reimbursement and coding
No separate named-product Medicare payment was identified in the reviewed CMS coverage material. Evaluate the product within the applicable imaging, procedural, surgical, or diagnostic service line and verify payer, site-of-service, and coding assumptions independently.
  • Public source
  • Not applicable
  • Checked 2026-09-04

No product-specific code

No separate named-product payment identified in reviewed public material

Centers for Medicare & Medicaid Services · United States

Build a local total-cost and value model; do not infer reimbursement from FDA clearance or approval.

Safety and lifecycle

Postmarket record

Recall and adverse-event records are shown only after product matching. Adverse-event reports do not establish incidence or causality.

Postmarket safety review
The 2026-09-02 openFDA device-recall snapshot contained no record matched to K234154 by exact native submission identifier. This does not exclude product-family, later, or adverse-event information.
  • Public source
  • Exact FDA submission
  • Checked 2026-09-04

Exact-identifier review does not prove absence of all product-family safety signals.

Buyer worksheet

Open questions to take to the vendor

Open evaluation checklist

Research record

What has been checked

This audit distinguishes completed source review from fields that have not yet been researched.

Human reviewedStatus
2026-09-20Last searched
33Fields reviewed
12Source classes checked
0Screened PubMed leads
0Screened trial leads
0Unreviewed FDA recall leads

The refreshed discovery snapshot contains no PubMed or ClinicalTrials.gov candidates; no external evidence was promoted. The current discovery snapshot contains 0 PubMed and 0 ClinicalTrials.gov candidate records; its dated, count-matched human screening remains current. Unlinked candidates remain quarantined. Native FDA recall identifiers produced 0 postmarket candidate records; 0 have been reviewed (0 published, 0 rejected) and 0 remain unreviewed.

Candidate leads were screened against the exact product and tested version. Unlinked records remain quarantined.

Source classes: fda ai list, fda decision summary, fda decision material, peer reviewed literature, clinical trial registry, reimbursement policy, fda device recall, literature index, trial registry, pubmed, clinical trials, openfda device recall

Sources & history

How this profile was documented

Open the ledger for source dates, scope, and research-record updates.

View source ledger and history

Source ledger

  1. FDA 510(k) decision material K234154: uPMR 790

    U.S. Food and Drug Administration - Published 2024-05-24 - Accessed 2026-09-04

    Scope: identity, purpose, clinicalUse, modality, anatomy, intendedUsers, careSetting, workflowRole, input, output, limitations, evidenceSummary

  2. Artificial Intelligence-Enabled Medical Devices

    U.S. Food and Drug Administration - Accessed 2026-08-31

    Scope: regulatoryIdentity, modalityContext

  3. PubMed biomedical literature index

    U.S. National Library of Medicine - Accessed 2026-09-01

    Scope: evidenceDiscovery

  4. ClinicalTrials.gov study registry

    U.S. National Library of Medicine - Accessed 2026-09-01

    Scope: evidenceDiscovery, studyStatus

  5. Medicare Coverage Database

    Centers for Medicare & Medicaid Services - Accessed 2026-09-01

    Scope: coverage, codingContext

  6. openFDA Device Recall API

    U.S. Food and Drug Administration - Accessed 2026-09-02

    Scope: recallDiscovery, nativeSubmissionMatching

Research history

  1. K234154 FDA decision

    Regulatory record

    510(k)

  2. Source-review record updated

    Research record

    human reviewed

  3. Reader overview source-reviewed

    Editorial review

    Source-reviewed editorial overlay

Alternatives

Related tools to compare

FDA-cleared K254013

SubtleHD-PET (1.x)

Subtle Medical, Inc.

SubtleHD-PET 1.x is image-processing software that reduces PET or PET/CT/PET-MR image noise for images acquired with any radiotracer within the labeled workflow.

Modality
PET/SPECT/Nuclear Medicine
Anatomy
Whole body and the body regions represented in PET studies
Decision
2026-05-14
FDA-cleared K260524

uMI Panvivo (uMI Panvivo LS); uMI Panvivo (uMI Panvivo); uMI Panvivo (uMI Panvivo S); uMI Panvivo (uMI Panvivo EX); uMI Panvivo (uMI Panvivo ES)

Shanghai United Imaging Healthcare Co., Ltd.

uMI Panvivo variants acquire and display PET and CT information for anatomical and functional imaging, radiopharmaceutical distribution, attenuation correction, and the labeled...

Modality
PET/SPECT/Nuclear Medicine
Anatomy
Whole body; brain; head and neck; heart; lung; breast; gastrointestinal; urinary; genital; and musculoskeletal anatomy
Decision
2026-04-03
FDA-cleared K253564

uMI Panvivo (uMI Panvivo); uMI Panvivo (uMI Panvivo S); uMI Panvivo (uMI Panvivo EX); uMI Panvivo (uMI Panvivo ES)

Shanghai United Imaging Healthcare Co., Ltd.

uMI Panvivo PET/CT acquires anatomical CT and functional PET images of radiopharmaceutical distribution for qualified diagnostic and treatment-planning workflows, including...

Modality
PET/SPECT/Nuclear Medicine
Anatomy
Whole body, head and neck, cardiac, and other labeled PET/CT regions
Decision
2026-02-13
FDA-cleared K253023

BIOGRAPH One

Siemens Healthineers AG

BIOGRAPH One with syngo MR XB10 combines metabolic or physiologic PET information with MR anatomy, MR-based attenuation correction, fused alignment, and support for treatment...

Modality
PET/SPECT/Nuclear Medicine
Anatomy
Multi-region
Decision
2026-01-15