FDA-cleared profile

Seg Pro V3 (RT-300)

Ever Fortune.Ai, Co., Ltd.

Authorized purpose: Seg Pro V3 generates initial organ-at-risk contours on DICOM images for radiation-treatment planning by radiation oncologists, medical physicists, and dosimetrists; the contours require professional review and editing.

Evidence status: each field states its source quality, applicability, and review date. Research pending, information not established, and vendor documentation pending remain distinct outcomes.

Product overview

Start with the essentials

Authorized purpose: Seg Pro V3 generates initial organ-at-risk contours on DICOM images for radiation-treatment planning by radiation oncologists, medical physicists, and dosimetrists; the contours require professional review and editing.

Overview status: Source-reviewed overview

Clinical takeaway

Clinical role: Seg Pro V3 generates initial organ-at-risk contours on DICOM images for radiation-treatment planning by radiation oncologists, medical physicists, and dosimetrists; the contours require professional review and editing.

Evidence takeaway

Evidence from the reviewed source record: The exact FDA decision material describes deep-learning processing, adult use, hospital-grade server and IT workflow, DICOM input, RTSTRUCT output, and a role limited to initial organ-at-risk contours rather than autonomous clinical decision or lesion detection.

Clinical details

What this tool is for

Start with the authorized purpose, then verify how it fits your service line and reading workflow.

Exact purpose
Seg Pro V3 generates initial organ-at-risk contours on DICOM images for radiation-treatment planning by radiation oncologists, medical physicists, and dosimetrists; the contours require professional review and editing.
  • FDA source
  • Exact FDA submission
  • Checked 2026-09-04
Intended users
Qualified radiation oncologists, medical physicists, dosimetrists, and radiation therapists.
  • FDA source
  • Exact FDA submission
  • Checked 2026-09-04
Care setting and population
Radiation-oncology departments using compatible planning, imaging, and treatment-delivery systems.
  • FDA source
  • Exact FDA submission
  • Checked 2026-09-04
Workflow role
Radiotherapy contouring, treatment planning, adaptation, or treatment-session support under professional review.
  • FDA source
  • Exact FDA submission
  • Checked 2026-09-04
Required input
Supported CT or MR images, structures, prescriptions, plans, registrations, and treatment-session data.
  • FDA source
  • Exact FDA submission
  • Checked 2026-09-04
Output and human action
Contours, treatment plans, adapted plans, dose or evaluation results, or session information requiring review and approval.
  • FDA source
  • Exact FDA submission
  • Checked 2026-09-04
Limitations
Generated or modified contours and plans require qualified review, editing when needed, independent checks, and final approval before treatment.
  • FDA source
  • Exact FDA submission
  • Checked 2026-09-04

Regulatory identity

FDA record and catalog context

The FDA listing establishes the regulatory identity. It does not by itself establish local workflow fit, pricing, security, or performance in your environment.

FDA submission
K251306
  • FDA source
  • Exact FDA submission
  • Checked 2026-08-31
Modality
Radiotherapy Planning Imaging
  • FDA source
  • Exact FDA submission
  • Checked 2026-09-04
Anatomy
Head, neck, brain, thorax, abdomen, pelvis, and other labeled radiation-treatment regions
  • FDA source
  • Exact FDA submission
  • Checked 2026-09-04
Clearance type
510(k)
  • FDA source
  • Exact FDA submission
  • Checked 2026-08-31
Decision date
2026-01-28
  • FDA source
  • Exact FDA submission
  • Checked 2026-08-31
FDA status
FDA-cleared
  • FDA source
  • Exact FDA submission
  • Checked 2026-08-31

Implementation

Questions for IT, informatics, and operations

Use these fields to structure a vendor demo, security review, and implementation estimate.

Integration
Not established in reviewed sources
  • Reviewed sources checked
  • Exact FDA submission
  • Checked 2026-09-04

The public exact-submission material does not establish a complete integration contract. Confirm DICOM, worklist, identity, interfaces, exports, routing, audit behavior, and downtime locally.

Deployment and data flow
Not established in reviewed sources
  • Reviewed sources checked
  • Exact FDA submission
  • Checked 2026-09-04

The public exact-submission material does not establish the complete deployment topology, hosting responsibility, availability, upgrade path, or service contract.

Security and privacy
Vendor documentation pending
  • Vendor confirmation
  • Exact FDA submission
  • Checked 2026-09-04

Public materials reviewed for this exact release do not establish the complete security posture. Request data-flow, identity, audit, encryption, retention, remote-access, vulnerability-management, backup, and incident-response evidence.

Training and support
Only qualified radiation oncologists, medical physicists, dosimetrists, and radiation therapists should operate or interpret the product. Local onboarding should cover the exact release, supported population, limitations, failure examples, escalation, downtime, and competency documentation.
  • FDA source
  • Exact FDA submission
  • Checked 2026-09-04
Monitoring and change control
Monitor by exact hardware, software, model, and algorithm version; patient population; anatomy; protocol; operator; input quality; output edits or overrides; failed studies; repeat acquisition or rework; downstream impact; downtime; incidents; recalls; and updates. Track these product-specific limits: Generated or modified contours and plans require qualified review, editing when needed, independent checks, and final approval before treatment.
  • Public source
  • Product family
  • Checked 2026-09-04

Current vendor material is product-family context for K251306; confirm exact cleared version, enabled options, deployment, and local compatibility.

Release and scope verification

Map installed model, build, options, population, anatomy, inputs, outputs, and enabled functions to K251306 before acceptance.

exact submission · checked 2026-09-04

Later product-family features are not evidence that this cleared release includes them.

Interoperability acceptance

Exact public integration details remain incomplete; establish and test the supported input, output, identity, routing, archive, and downtime contract locally.

product family · checked 2026-09-04

Test representative identifiers, orientation, geometry, measurements, units, routing, failure handling, and round trips locally. Current vendor material is product-family context; confirm exact release, enabled options, deployment, and local compatibility.

Clinical acceptance

Use a signed local test set for the supported population and workflow. Include common and difficult cases, exclusions, acquisition variation, failed or low-quality inputs, reviewer overrides, and downstream effects. Generated or modified contours and plans require qualified review, editing when needed, independent checks, and final approval before treatment.

exact submission · checked 2026-09-04

Define stop-use, escalation, rollback, and revalidation triggers before production use.

Economic evaluation

Model capital and recurring cost against net staff time after review, throughput, repeat imaging or rework, room time, consumables, infrastructure, training, service, downtime, upgrade, and replacement costs.

product family · checked 2026-09-04

No exact-product price was found in the reviewed public material; productivity or value claims require local evidence.

Lifecycle monitoring

Monitor by exact hardware, software, model, and algorithm version; patient population; anatomy; protocol; operator; input quality; output edits or overrides; failed studies; repeat acquisition or rework; downstream impact; downtime; incidents; recalls; and updates. Track these product-specific limits: Generated or modified contours and plans require qualified review, editing when needed, independent checks, and final approval before treatment.

product family · checked 2026-09-04

Revalidate after material software, hardware, model, protocol, interface, or clinical-policy changes. Current vendor material is product-family context; confirm exact release, enabled options, deployment, and local compatibility.

Evidence

Performance evidence

Metrics are shown only when they are tied to a source, endpoint, population, and tested product version. Candidate literature without exact product and version linkage is not shown as product evidence.

Evidence summary
The exact FDA decision material describes deep-learning processing, adult use, hospital-grade server and IT workflow, DICOM input, RTSTRUCT output, and a role limited to initial organ-at-risk contours rather than autonomous clinical decision or lesion detection.
  • FDA source
  • Exact FDA submission
  • Checked 2026-09-04
Reported sensitivity
Not applicable
  • Not applicable
  • Not applicable
  • Checked 2026-09-04

Sensitivity is not a product-wide endpoint for this system or software function. Compare only an exact endpoint, threshold, population, version, and source if one is later verified.

Reported specificity
Not applicable
  • Not applicable
  • Not applicable
  • Checked 2026-09-04

Specificity is not a product-wide endpoint for this system or software function. Compare only an exact endpoint, threshold, population, version, and source if one is later verified.

No contextualized exact-version metric has completed evidence review. Regulatory-document values, when available, are shown above with their limitations.

K251306 FDA evidence package for Seg Pro V3 (RT-300)

  • DesignFDA software substantial-equivalence decision with contouring, DICOM RTSTRUCT, algorithm, usability, and workflow verification
  • PopulationAdult radiation-treatment planning cases using supported DICOM images and labeled organs at risk
  • Scopeexact submission
  • Tested versionSeg Pro V3
  • IndependenceSponsor or vendor study

K251306

Manufacturer evidence submitted for the exact FDA decision. It is not independent clinical validation, and local technical, clinical, privacy, security, and workflow acceptance remains necessary.

Costs and setup

Budget and ongoing governance

These are common procurement questions; unknown values remain visible until a source supports them.

Pricing and total cost
Not established in reviewed sources
  • Reviewed sources checked
  • Exact FDA submission
  • Checked 2026-09-04

No public list price for the exact cleared configuration was found. Obtain a written quote separating hardware or license basis, implementation, interfaces, infrastructure, training, service, upgrades, renewal, consumables, and exit costs.

Reimbursement and coding
No separate named-product Medicare payment was identified in the reviewed CMS radiation-oncology material. Evaluate net planning or delivery value within the radiotherapy service line.
  • Public source
  • Not applicable
  • Checked 2026-09-04

No product-specific code

No separate named-product payment identified in reviewed public material

Centers for Medicare & Medicaid Services · United States

Build a local total-cost and value model; do not infer reimbursement from FDA clearance or approval.

Safety and lifecycle

Postmarket record

Recall and adverse-event records are shown only after product matching. Adverse-event reports do not establish incidence or causality.

Postmarket safety review
The 2026-09-02 openFDA device-recall snapshot contained no record matched to K251306 by exact native submission identifier. This does not exclude product-family, later, or adverse-event information.
  • Public source
  • Exact FDA submission
  • Checked 2026-09-04

Exact-identifier review does not prove absence of all product-family safety signals.

Buyer worksheet

Open questions to take to the vendor

Open evaluation checklist

Research record

What has been checked

This audit distinguishes completed source review from fields that have not yet been researched.

Human reviewedStatus
2026-09-20Last searched
27Fields reviewed
12Source classes checked
0Screened PubMed leads
0Screened trial leads
0Unreviewed FDA recall leads

The refreshed discovery snapshot contains no PubMed or ClinicalTrials.gov candidates; no external evidence was promoted. The current discovery snapshot contains 0 PubMed and 0 ClinicalTrials.gov candidate records; its dated, count-matched human screening remains current. Unlinked candidates remain quarantined. Native FDA recall identifiers produced 0 postmarket candidate records; 0 have been reviewed (0 published, 0 rejected) and 0 remain unreviewed.

Candidate leads were screened against the exact product and tested version. Unlinked records remain quarantined.

Source classes: fda ai list, fda decision material, vendor product page, peer reviewed literature, clinical trial registry, reimbursement policy, fda device recall, literature index, trial registry, pubmed, clinical trials, openfda device recall

Sources & history

How this profile was documented

Open the ledger for source dates, scope, and research-record updates.

View source ledger and history

Source ledger

  1. FDA 510(k) decision material K251306: Seg Pro V3 (RT-300)

    U.S. Food and Drug Administration - Published 2026-01-28 - Accessed 2026-09-04

    Scope: identity, purpose, clinicalUse, modality, anatomy, intendedUsers, careSetting, workflowRole, input, output, limitations, evidenceSummary

  2. Artificial Intelligence-Enabled Medical Devices

    U.S. Food and Drug Administration - Accessed 2026-08-31

    Scope: regulatoryIdentity, modalityContext

  3. PubMed biomedical literature index

    U.S. National Library of Medicine - Accessed 2026-09-01

    Scope: evidenceDiscovery

  4. ClinicalTrials.gov study registry

    U.S. National Library of Medicine - Accessed 2026-09-01

    Scope: evidenceDiscovery, studyStatus

  5. openFDA Device Recall API

    U.S. Food and Drug Administration - Accessed 2026-09-02

    Scope: recallDiscovery, nativeSubmissionMatching

  6. Radiation Oncology Model

    Centers for Medicare & Medicaid Services - Accessed 2026-09-02

    Scope: reimbursement, radiationTherapyPaymentContext

  7. Seg Pro family

    Ever Fortune - Accessed 2026-09-04

    Scope: productFamilyContext, workflowRole, implementationCapabilities

Research history

  1. K251306 FDA decision

    Regulatory record

    510(k)

  2. Source-review record updated

    Research record

    human reviewed

  3. Reader overview source-reviewed

    Editorial review

    Source-reviewed editorial overlay

Alternatives

Related tools to compare

FDA-cleared K253050

RadOncAI

Informai

RadOncAI provides AI-guided dose prediction from CT simulation and clinician-defined treatment-planning structures for adult head-and-neck malignant or benign disease.

Modality
Radiotherapy Planning Imaging
Anatomy
Head and neck
Decision
2026-06-18
FDA-cleared K252190

DeepBT Detector-Plus

Aitewan Biomedical Technology, Inc.

DeepBT Detector-Plus provides initial gross-tumor-volume contours on T1-weighted contrast-enhanced and optional T2-weighted MR images for radiation-treatment planning in adults...

Modality
Radiotherapy Planning Imaging
Anatomy
Brain tumors, including metastases, meningiomas, and acoustic neuromas
Decision
2026-04-10
FDA-cleared K252548

AI-Rad Companion Organs RT

Siemens Healthcare GmbH

AI-Rad Companion Organs RT VA70 automatically contours predefined structures, including known diagnosed brain metastases, on DICOM CT and MR images for radiation therapy planning;...

Modality
Radiotherapy Planning Imaging
Anatomy
Head/neck, thorax, abdomen, pelvis; MR brain and male pelvis
Decision
2026-04-10
FDA-cleared K260509

AutoContour (RADAC V5)

Radformation, Inc.

AutoContour Model RADAC V5 assists radiation treatment planners with contouring and reviewing structures in medical images for radiation therapy treatment planning. It produces...

Modality
Radiotherapy Planning Imaging
Anatomy
Multi-region
Decision
2026-03-19