Overjet Dental Assist is a radiological semi-automated image processing software device intended to aid dental professionals in the measurements of mesial and distal bone levels associated with each tooth from bitewing and periapical radiographs. It should not be used in-lieu of full patient evaluation or solely relied upon to make or confirm a diagnosis. The system is to be used by trained professionals including, but not limited to, dentists and dental hygienists. Intended Patient Population: The intended patient population of the device is patients living in the United States, who are 22 years old or older, and that do not have any remaining primary teeth. Overjet has not evaluated the performance of the device on primary dentition.
Evidence status: each field shows source quality, applicability, and review date. Research pending, information not established in reviewed sources, and vendor documentation pending are distinct outcomes.
Clinical fit
What this tool is for
Start with the authorized purpose, then verify how it fits your service line and reading workflow.
Exact purpose
Overjet Dental Assist is a radiological semi-automated image processing software device intended to aid dental professionals in the measurements of mesial and distal bone levels associated with each tooth from bitewing and periapical radiographs. It should not be used in-lieu of full patient evaluation or solely relied upon to make or confirm a diagnosis. The system is to be used by trained professionals including, but not limited to, dentists and dental hygienists. Intended Patient Population: The intended patient population of the device is patients living in the United States, who are 22 years old or older, and that do not have any remaining primary teeth. Overjet has not evaluated the performance of the device on primary dentition.
Public source Exact FDA submission Checked 2026-09-01
Exact-submission indication text from the ACR AI Central model card. FDA labeling remains controlling.
XRAY images or data. Inclusion criteria: Bitewing and periapical radiographs from patients 22 years old or older without any remaining primary teeth, living in the United States
Public source Exact FDA submission Checked 2026-09-01
Conservative normalization of explicit wording in an exact-submission source.
The AI model outputs measurements of mesial and distal (interproximal) bone levels associated with each tooth from bitewing and periapical radiographs. The system provides annotations and linear distance measurements of interproximal bone levels, which dental professionals can review, view, and modify.
Public source Exact FDA submission Checked 2026-09-01
Clinical output reported in the exact-submission ACR model card.
The FDA listing establishes the regulatory identity. It does not by itself establish local workflow fit, pricing, security, or performance in your environment.
FDA submission
K210187
FDA source Exact FDA submission Checked 2026-08-31
Use these fields to structure a vendor demo, security review, and implementation estimate.
Integration
Standards-based DICOM/PACS integration was identified in the FDA submission materials; compatibility with a specific PACS, RIS, EHR, or orchestrator requires confirmation.
Public source Exact FDA submission Checked 2026-08-13
Normalized from the prior exact-submission review. Confirm interface versions and local compatibility during technical evaluation.
Needs research Exact FDA submission Checked 2026-08-31
Attach an exact-product deployment and data-flow source.
Security and privacy
Vendor documentation pending
Vendor confirmation Exact FDA submission Checked 2026-08-13
FDA authorization does not establish the current commercial security posture. Request data-flow diagrams, hosting and retention details, access controls, audit logging, attestations, and incident-response documentation.
Training and support
Vendor documentation pending
Vendor confirmation Exact FDA submission Checked 2026-08-13
Training, onboarding, competency, and support commitments are commercial implementation details that require current vendor documentation.
Monitoring and change control
Vendor documentation pending
Vendor confirmation Exact FDA submission Checked 2026-08-13
Local acceptance testing, production monitoring, drift review, update control, and incident escalation require a current vendor and site-specific governance plan.
Supported acquisition environment
Scanner manufacturers: All
exact submission · checked 2026-09-01
Confirm currently supported software versions, protocols, and site-specific acquisition configurations.
No contextualized exact-version metric has completed evidence review. Regulatory-document values, when available, are shown above with their limitations.
Overjet Dental Assist regulatory performance study summary
Stand-Alone Performance · Population described in the exact-submission ACR model card
exact submission · Tested version: Exact product version not reported; regulatory study summarized for FDA submission K210187 · n=63 · Independence not established
K210187
ACR AI Central summarizes the regulatory study; consult the exact FDA materials before comparative use.
These are common procurement questions; unknown values remain visible until a source supports them.
Pricing and total cost
Vendor documentation pending
Vendor confirmation Exact FDA submission Checked 2026-08-13
FDA submission materials do not establish current commercial pricing. Request the pricing unit, term, minimum commitment, implementation fees, and included support from the vendor.
Reimbursement and coding
Research pending
Needs research Exact FDA submission Checked 2026-08-31
Determine whether any product-specific CPT/HCPCS pathway exists and separate it from billing for the underlying imaging service.
Safety and lifecycle
Postmarket record
Recall and adverse-event records are shown only after product matching. Adverse-event reports do not establish incidence or causality.
Postmarket safety review
Not established in reviewed sources
Reviewed sources checked Exact FDA submission Checked 2026-09-04
No native submission-identifier match was found in the checked openFDA radiology recall snapshot. Product-name, manufacturer, and adverse-event searches remain necessary; this does not establish that no recall or safety report exists.
Buyer worksheet
Open questions to take to the vendor
Verify care setting and population: Confirm the intended care setting, patient population, and service line.
Verify deployment and data flow: Attach an exact-product deployment and data-flow source.
Verify security and privacy controls: FDA authorization does not establish the current commercial security posture. Request data-flow diagrams, hosting and retention details, access controls, audit logging, attestations, and incident-response documentation.
Verify training: Training, onboarding, competency, and support commitments are commercial implementation details that require current vendor documentation.
Verify pricing and total cost: FDA submission materials do not establish current commercial pricing. Request the pricing unit, term, minimum commitment, implementation fees, and included support from the vendor.
Verify reimbursement and coding relevance: Determine whether any product-specific CPT/HCPCS pathway exists and separate it from billing for the underlying imaging service.
Verify local validation and lifecycle monitoring: Local acceptance testing, production monitoring, drift review, update control, and incident escalation require a current vendor and site-specific governance plan.
Verify recalls and postmarket safety signals: No native submission-identifier match was found in the checked openFDA radiology recall snapshot. Product-name, manufacturer, and adverse-event searches remain necessary; this does not establish that no recall or safety report exists.
This audit distinguishes completed source review from fields that have not yet been researched.
Exact FDA record reviewedStatus
2026-09-04Last searched
18Fields reviewed
6Source classes checked
0Unreviewed PubMed leads
0Unreviewed trial leads
0Unreviewed FDA recall leads
Exact-submission ACR model-card fields were normalized under the current provenance rules; vendor and independent-study confirmation remain distinct. Automated exact-name discovery found 0 PubMed and 0 ClinicalTrials.gov candidate records. Candidates require human product and version matching; zero candidates is not evidence that no studies exist. Native FDA recall identifiers produced 0 postmarket candidate records; 0 have been reviewed (0 published, 0 rejected) and 0 remain unreviewed.
Candidate leads remain unpublished until a human confirms the exact product and tested version.
Source classes: fda ai list, fda decision summary, acr ai central product, pubmed, clinical trials, openfda device recall