Authorized purpose: LiverMultiScan v5 (LMSv5) is indicated for use as a magnetic resonance diagnostic device software application for noninvasive liver evaluation that enables the generation, display and review of 2D magnetic resonance medical image data and pixel maps for MR relaxation times.LMSv5 is designed to utilize DICOM 3.0 compliant magnetic resonance image datasets, acquired from compatible MRSystems, to display the internal structure of the abdomen including the liver. Other physical parameters derived from the images may also be produced.LMSv5 provides several tools, such as automated liver segmentation and region of interest (ROI) placements, to be used for the assessment of selected regions of an image. Quantitative assessment of selected regions includes the determination of triglyceride fat fraction in the liver (PDFF), T2*, LIC (Liver Iron Concentration) and iron corrected T1(cT1) measurements. These images and the physical parameters derived from the images, when interpreted by a trained clinician, yield information that may assist in diagnosis.
Clinical role
Segmentation or contouring
Images and patients
MRI · Liver
Key limitation
Keep in mind: LiverMultiScan v5 is not a computer-aided diagnostic device and can only present imaging information which must be interpreted by a qualified clinician. The diagnosis and treatment decisions remain the responsibility of the clinician.
Clinical detailsPurpose, workflow fit, evidence, and safety record
Workflow navigation pilot
Workflow role has not yet been reviewed for this navigation pilot.
A tag identifies a documented role; it does not establish compatibility or local acceptance. Methods and sources
What does this software do?Authorized purpose: LiverMultiScan v5 (LMSv5) is indicated for use as a magnetic resonance diagnostic device software application for noninvasive liver evaluation that enables the generation, display and review of 2D magnetic resonance medical image data and pixel maps for MR relaxation times.LMSv5 is designed to utilize DICOM 3.0 compliant magnetic resonance image datasets, acquired from compatible MRSystems, to display the internal structure of the abdomen including the liver. Other physical parameters derived from the images may also be produced.LMSv5 provides several tools, such as automated liver segmentation and region of interest (ROI) placements, to be used for the assessment of selected regions of an image. Quantitative assessment of selected regions includes the determination of triglyceride fat fraction in the liver (PDFF), T2*, LIC (Liver Iron Concentration) and iron corrected T1(cT1) measurements. These images and the physical parameters derived from the images, when interpreted by a trained clinician, yield information that may assist in diagnosis.
Which images or clinical context are in scope?Modality: MRI Anatomy or clinical context: Liver Input: MRI images or data involving Liver; consult the FDA labeling for exact protocol, series, and quality requirements.
Who uses it?Intended users: The purpose of the LiverMultiScan v5 device is to assist a trained operator with the evaluation of information from Magnetic Resonance (MR) images from a single time-point (a patient visit). A summary report from the analysis conducted is generated for interpretation by a clinician.
What does the software produce?Output: Proton Density Fat Fraction in the liver (PDFF), Liver Iron Concentration in of the liver (LIC) and T1 corrected for liver iron concentration, scanner manufacturer and field strength (cT1),
What is its most important limitation?Key limitation: LiverMultiScan v5 is not a computer-aided diagnostic device and can only present imaging information which must be interpreted by a qualified clinician. The diagnosis and treatment decisions remain the responsibility of the clinician.
Clinical takeaway. Clinical role: LiverMultiScan v5 (LMSv5) is indicated for use as a magnetic resonance diagnostic device software application for noninvasive liver evaluation that enables the generation, display and review of 2D magnetic resonance medical image data and pixel maps for MR relaxation times.LMSv5 is designed to utilize DICOM 3.0 compliant magnetic resonance image datasets, acquired from compatible MRSystems, to display the internal structure of the abdomen including the liver. Other physical parameters derived from the images may also be produced.LMSv5 provides several tools, such as automated liver segmentation and region of interest (ROI) placements, to be used for the assessment of selected regions of an image. Quantitative assessment of selected regions includes the determination of triglyceride fat fraction in the liver (PDFF), T2*, LIC (Liver Iron Concentration) and iron corrected T1(cT1) measurements. These images and the physical parameters derived from the images, when interpreted by a trained clinician, yield information that may assist in diagnosis.
Evidence takeaway. Evidence from the reviewed source record: LiverMultiScan v5 underwent performance testing under controlled conditions to corroborate that it is safe and effective when used as intended. The performance testing conducted demonstrates that LiverMultiScan v5 is at least as safe and effective as the predicate devices.
Purpose
LiverMultiScan v5 (LMSv5) is indicated for use as a magnetic resonance diagnostic device software application for noninvasive liver evaluation that enables the generation, display and review of 2D magnetic resonance medical image data and pixel maps for MR relaxation times.LMSv5 is designed to utilize DICOM 3.0 compliant magnetic resonance image datasets, acquired from compatible MRSystems, to display the internal structure of the abdomen including the liver. Other physical parameters derived from the images may also be produced.LMSv5 provides several tools, such as automated liver segmentation and region of interest (ROI) placements, to be used for the assessment of selected regions of an image. Quantitative assessment of selected regions includes the determination of triglyceride fat fraction in the liver (PDFF), T2*, LIC (Liver Iron Concentration) and iron corrected T1(cT1) measurements. These images and the physical parameters derived from the images, when interpreted by a trained clinician, yield information that may assist in diagnosis.
Proton Density Fat Fraction in the liver (PDFF), Liver Iron Concentration in of the liver (LIC) and T1 corrected for liver iron concentration, scanner manufacturer and field strength (cT1),
Exact FDA submission
Checked 2026-09-19
Exact FDA decision-summary packet reviewed on 2026-09-19; existing wording is supported without expansion.
The purpose of the LiverMultiScan v5 device is to assist a trained operator with the evaluation of information from Magnetic Resonance (MR) images from a single time-point (a patient visit). A summary report from the analysis conducted is generated for interpretation by a clinician.
Exact FDA submission
Checked 2026-09-19
The exact packet names a trained operator and a clinician interpreter; it does not establish a Perspectum-specific user class.
LiverMultiScan v5 is not a computer-aided diagnostic device and can only present imaging information which must be interpreted by a qualified clinician. The diagnosis and treatment decisions remain the responsibility of the clinician.
Exact FDA submission
Checked 2026-09-19
This replaces unsupported scanner, slice-thickness, and field-strength claims with the packet's direct clinical-use boundary.
LiverMultiScan v5 underwent performance testing under controlled conditions to corroborate that it is safe and effective when used as intended. The performance testing conducted demonstrates that LiverMultiScan v5 is at least as safe and effective as the predicate devices.
Exact FDA submission
Checked 2026-09-19
The replacement retains the packet's direct performance-testing conclusion without adding an unspecified reference standard.
Metrics are shown only when they are tied to a source, endpoint, population, and tested product version. Candidate literature without exact product and version linkage is not shown as product evidence.
Evidence summary
LiverMultiScan v5 underwent performance testing under controlled conditions to corroborate that it is safe and effective when used as intended. The performance testing conducted demonstrates that LiverMultiScan v5 is at least as safe and effective as the predicate devices.
FDA source
Exact FDA submission
Checked 2026-09-19
The replacement retains the packet's direct performance-testing conclusion without adding an unspecified reference standard.
No contextualized exact-version metric has completed evidence review. Regulatory-document values, when available, are shown above with their limitations.
LiverMultiScan regulatory performance study summary
DesignStand-Alone Performance
PopulationAdult and Pediatric
Scopeexact submission
Tested versionv5.1
IndependenceIndependence not established
K213960
ACR AI Central summarizes the regulatory study; consult the exact FDA materials before comparative use.
Recall and adverse-event records are shown only after product matching. Adverse-event reports do not establish incidence or causality.
Postmarket safety review
The exact-identifier FDA recall query returned no native recall record for K213960. This limited result does not establish absence of recalls or other safety information and does not cover later versions, family records, MAUDE reports, corrections, or field notices.
IT implementationDeployment, interfaces, data handling, and support
System and version relationships
Match the AI release, system build, configuration and region. Source documentation does not establish acceptance of an installed system.
No specific system/version pairing has completed review for this FDA record. A broad DICOM or product-family statement does not establish a named viewer build's support.
Deployment category preserved from the prior exact-submission review; hosting region, data flow, and current commercial configuration still require vendor confirmation.
The exact-submission ACR model card explicitly references DICOM in the described input, output, or workflow; exact interfaces, versions, and local compatibility require confirmation.
Exact FDA submission
Checked 2026-09-01
Interoperability terms explicitly reported in the exact-submission ACR model card; interface versions and local compatibility still require confirmation.
Perspectum's compliance and trust page states the company has attained ISO 27001 certification for information security management systems and ISO 13485 for medical-device quality management, and adheres to UK GDPR, EU GDPR, and HIPAA with measures to safeguard personal data, with dedicated teams continuously assessing and updating security practices.
Vendor-wide
Checked 2026-10-27
Vendor statement; certificates were not read. Applicant name variants (Perspectum, Perspectum Ltd/LTD, Perspectum Diagnostics Ltd) are bridged via the identical distinctive name and LiverMultiScan/Hepatica/MRCP+ product naming on the owning domain. Exact-release scope is not established.
ACR AI Central provides an exact-submission model card for LiverMultiScan v5 (LMSv5); FDA labeling remains controlling for clinical use, limitations, and performance.
Sources & review detailsFDA identity, research record, source ledger, and history
Regulatory identity
FDA record and catalog context
The FDA listing establishes the regulatory identity. It does not by itself establish local workflow fit, pricing, security, or performance in your environment.
This audit distinguishes completed source review from fields that have not yet been researched.
Exact FDA record reviewedStatus
2026-09-20Last searched
25Fields reviewed
10Source classes checked
20Screened PubMed leads
10Screened trial leads
0Unreviewed FDA recall leads
The refreshed discovery snapshot contains 20 PubMed and 10 ClinicalTrials.gov candidate records. Discovery metadata alone does not establish exact tested-product, version, population, and endpoint applicability, so all candidates remain quarantined and none was promoted. The current discovery snapshot contains 20 PubMed and 10 ClinicalTrials.gov candidate records; its dated, count-matched human screening remains current. Unlinked candidates remain quarantined. Native FDA recall identifiers produced 0 postmarket candidate records; 0 have been reviewed (0 published, 0 rejected) and 0 remain unreviewed.
Candidate leads were screened against the exact product and tested version. Unlinked records remain quarantined.
Source classes: fda ai list, fda decision summary, acr ai central product, fda device recall, literature index, trial registry, fda decision summary packet, pubmed, clinical trials, openfda device recall
Field review details
Recorded state, verification date, notes and sources for fields without a publishable value. Conflicting records stay explicitly unsettled here; no plain settled value is shown for them.
Public pricing: Not verified - checked 2026-09-08 - Exact FDA submission
No public price or quote for the exact K213960 configuration was established in this review.
Pricing model: Not yet reviewed
Setup and integration fees: Not yet reviewed
Recurring fees: Not yet reviewed
Minimum commitment: Not yet reviewed
Contract duration: Not yet reviewed
Renewal terms: Not yet reviewed
Cancellation terms: Not yet reviewed
Support and service terms: Not yet reviewed
Trial or pilot terms: Not yet reviewed
Reimbursement: Not publicly available - checked 2026-09-08 - Exact FDA submission
No exact-product payer policy, coding instruction, or payment determination was established; eligibility must be evaluated by payer, site of service, and use case.
Data hosting location: Not yet reviewed
Data retention: Not yet reviewed
Documented data use: Not yet reviewed
Hardware requirements: Not yet reviewed
Network requirements: Not yet reviewed
Identity and access: Not yet reviewed
Installation timeline: Not yet reviewed
Training: Not verified - checked 2026-09-08 - Exact FDA submission
Current training prerequisites, competency checks, and support commitments for the exact configuration require vendor confirmation.
Monitoring: Not verified - checked 2026-09-08 - Exact FDA submission
Current drift, quality, uptime, alert, escalation, and incident-response commitments for the exact configuration require vendor confirmation.
Authorized purpose: LiverMultiScan v6.0 is MR diagnostic software for non-invasive liver-health assessment that generates, displays, and supports review of MR data and quantitative cT1, PDFF, and LIC metrics or composite images for trained healthcare-professional interpretation.
Authorized purpose: Provide quantitative volumetric liver fat fraction, proton-density fat fraction, and steatosis grading to support clinical diagnosis and subsequent management decisions for confirmed or suspected fatty liver disease or metabolic syndromes and to aid living-donor liver-transplant assessment and screening, with results interpreted by a trained physician.
Authorized purpose: Measures liver iron concentration for specified iron-overload and thalassemia/sickle-cell indications; assesses VLFF, PDFF, and steatosis grade for suspected or confirmed fatty liver disease; physician-interpreted results may support weight-loss monitoring and living-donor assessment.
Authorized purpose: Hepatica (Hepatica v1) is a post-processing medical device software that presents quantified metrics which may contribute to the assessment of a patient's liver health. Hepatica (Hepatica v1) uses image visualization and analysis tools to process DICOM 3.0 compliant magnetic resonance image datasets to produce semi-automatic segmented 3D models of the liver based on the work of Couinaud and the Brisbane 2000 terminology. For each identified Couinaud segment, volumetric data is determined and reported. Hepatica (Hepatica v1) may also report iron corrected-T1 (cT1) and PDFF calculated using the IDEAL method from multi-slice acquisitions, on a per segment basis, over the whole liver. Both metrics present numerical values of different fundamental liver tissue characteristics that can be used as measures of liver tissue health. Hepatica (Hepatica v1) provides trained clinicians with additional information to evaluate the volume and health of patient's liver on a segmental basis. It is not intended to replace the established procedures for the assessment of patient's liver health. However, information gathered through existing diagnostic tests, clinical evaluation of the patient, as well Hepatica (Hepatica v1), may support surgical decision making.