- Integration
- K211655 describes DICOM transfer, a four-panel PET/CT/fusion/MIP display, ROI quantification, user quality control, electronic report confirmation, and archival workflow. Current EXINI or PYlarify material is product-family context and does not prove the exact deployed cloud configuration.
Public source Product family Checked 2026-09-03
Current vendor materials are product-family evidence for K211655; confirm the exact cleared version, enabled options, deployment, and local compatibility.
- Deployment and data flow
- Cloud-based web platform as described in K211655; confirm hosting region, tenant isolation, identity, retention, and current product build with the vendor.
Public source Product family Checked 2026-09-03
Current vendor materials are product-family evidence for K211655; confirm the exact cleared version, enabled options, deployment, and local compatibility.
- Security and privacy
- Vendor documentation pending
Vendor confirmation Exact FDA submission Checked 2026-09-03
Public materials reviewed for this exact release do not establish the complete security posture. Request data-flow, identity, audit, encryption, retention, remote-access, vulnerability-management, backup, and incident-response evidence.
- Training and support
- Only qualified nuclear medicine physicians, radiologists, and trained imaging analysts should operate or interpret the product. Local onboarding should cover the exact release, supported population, limitations, failure examples, escalation, downtime, and competency documentation.
FDA source Exact FDA submission Checked 2026-09-03
- Monitoring and change control
- Monitor by exact hardware, software, model, and algorithm version; patient population; anatomy; protocol; operator; input quality; output edits or overrides; failed studies; repeat acquisition or rework; downstream impact; downtime; incidents; recalls; and updates. Track these product-specific limits: Quantification depends on tracer, acquisition, reconstruction, segmentation, image quality, and user quality-control steps; candidate literature and current family materials do not establish exact-version performance unless explicitly linked to the submission.
Public source Product family Checked 2026-09-03
Current vendor materials are product-family evidence for K211655; confirm the exact cleared version, enabled options, deployment, and local compatibility.
Release and scope verification
Map the installed model, build, options, population, anatomy, inputs, outputs, and enabled AI functions to K211655 before acceptance.
exact submission · checked 2026-09-03 Later product-family features are not evidence that this cleared release includes them.
Interoperability acceptance
K211655 describes DICOM transfer, a four-panel PET/CT/fusion/MIP display, ROI quantification, user quality control, electronic report confirmation, and archival workflow. Current EXINI or PYlarify material is product-family context and does not prove the exact deployed cloud configuration.
product family · checked 2026-09-03 Test representative identifiers, orientation, geometry, measurements, units, routing, failure handling, and round trips locally. Vendor statements are current product-family context; confirm the exact cleared release and installed options.
Clinical acceptance
Use a signed local test set for the supported population and workflow. Include common and difficult cases, exclusions, acquisition variation, failed or low-quality inputs, reviewer overrides, and downstream effects. Quantification depends on tracer, acquisition, reconstruction, segmentation, image quality, and user quality-control steps; candidate literature and current family materials do not establish exact-version performance unless explicitly linked to the submission.
exact submission · checked 2026-09-03 Define stop-use, escalation, rollback, and revalidation triggers before production use.
Economic evaluation
Model capital and recurring cost against net staff time after review, throughput, repeat imaging or rework, room time, consumables, infrastructure, training, service, downtime, upgrade, and replacement costs.
product family · checked 2026-09-03 No exact-product price was found in the reviewed public material; vendor productivity claims are scenario inputs, not guaranteed local savings.
Lifecycle monitoring
Monitor by exact hardware, software, model, and algorithm version; patient population; anatomy; protocol; operator; input quality; output edits or overrides; failed studies; repeat acquisition or rework; downstream impact; downtime; incidents; recalls; and updates. Track these product-specific limits: Quantification depends on tracer, acquisition, reconstruction, segmentation, image quality, and user quality-control steps; candidate literature and current family materials do not establish exact-version performance unless explicitly linked to the submission.
product family · checked 2026-09-03 Revalidate after material software, hardware, model, protocol, interface, or clinical-policy changes. Vendor statements are current product-family context; confirm the exact cleared release and installed options.