FDA-cleared profile

AmCAD-UO

AmCad BioMed Corporation

Authorized purpose: AmCAD-UO analyzes pharyngeal and upper-airway ultrasonic images to visualize and quantify airway structures for physician evaluation and monitoring.

Evidence status: each field states its source quality, applicability, and review date. Research pending, information not established, and vendor documentation pending remain distinct outcomes.

Product overview

Start with the essentials

Authorized purpose: AmCAD-UO analyzes pharyngeal and upper-airway ultrasonic images to visualize and quantify airway structures for physician evaluation and monitoring.

Overview status: Source-reviewed overview

Clinical takeaway

Clinical role: AmCAD-UO analyzes pharyngeal and upper-airway ultrasonic images to visualize and quantify airway structures for physician evaluation and monitoring.

Evidence takeaway

Evidence from the reviewed source record: K180867 reports software, ultrasonic-image processing, measurement, and validation testing for the upper-airway workflow. The public FDA summary does not establish a clinical outcome, sensitivity, or specificity value.

Clinical details

What this tool is for

Start with the authorized purpose, then verify how it fits your service line and reading workflow.

Exact purpose
AmCAD-UO analyzes pharyngeal and upper-airway ultrasonic images to visualize and quantify airway structures for physician evaluation and monitoring.
  • FDA source
  • Exact FDA submission
  • Checked 2026-09-19

Clinical-use display mirrors the exact FDA-supported purpose reconciled from the decision-summary packet.

Intended users
Physician evaluation and monitoring of the airway state.
  • FDA source
  • Exact FDA submission
  • Checked 2026-09-19

The packet names physician evaluation and monitoring but does not establish sonographers or a broader trained-professional class.

Care setting and population
Hospitals, clinics, offices, operating rooms, and point-of-care environments within the cleared applications.
  • FDA source
  • Exact FDA submission
  • Checked 2026-09-03
Workflow role
Ultrasound acquisition, measurement, analysis, reporting, and release-specific AI assistance.
  • FDA source
  • Exact FDA submission
  • Checked 2026-09-03
Required input
The pharyngeal/upper airway ultrasonic image acquired from an FDA-cleared ultrasound system.
  • FDA source
  • Exact FDA submission
  • Checked 2026-09-19

This is the packet's input boundary and does not establish live or imported data from supported probes, host devices, and applications.

Output and human action
The software is designed to support visualization and quantification of the airway sonographic characteristics. The software also provides tools for manual or interactive selection of Region of Interest to allow for analysis of the airway in terms of its size, position and enhancement pattern.
  • FDA source
  • Exact FDA submission
  • Checked 2026-09-19

The packet supports visualization, quantification, and region-of-interest analysis but does not establish the dossier's generic images, overlays, calculations, and reports bundle.

Limitations
Use only supported upper-airway image inputs and measurements. The output supports physician evaluation and monitoring and is not a stand-alone diagnosis or airway-management decision.
  • FDA source
  • Exact FDA submission
  • Checked 2026-09-03

Regulatory identity

FDA record and catalog context

The FDA listing establishes the regulatory identity. It does not by itself establish local workflow fit, pricing, security, or performance in your environment.

FDA submission
K180867
  • FDA source
  • Exact FDA submission
  • Checked 2026-08-31
Modality
Ultrasound
  • FDA source
  • Exact FDA submission
  • Checked 2026-09-19

Exact FDA decision-summary packet reviewed on 2026-09-19; existing wording is supported without expansion.

Anatomy
Head/Neck
  • FDA source
  • Exact FDA submission
  • Checked 2026-09-19

The exact indication names the pharyngeal/upper airway and does not establish the broader Head/Neck label. Controlled directory display reconciled from exact FDA wording: Pharyngeal/upper airway. -> Head/Neck.

Clearance type
510(k)
  • FDA source
  • Exact FDA submission
  • Checked 2026-08-31
Decision date
2018-12-28
  • FDA source
  • Exact FDA submission
  • Checked 2026-08-31
FDA status
FDA-cleared
  • FDA source
  • Exact FDA submission
  • Checked 2026-08-31

Implementation

Questions for IT, informatics, and operations

Use these fields to structure a vendor demo, security review, and implementation estimate.

Integration
Validate supported probes and host devices, patient matching, DICOM or local export, PACS measurements, worklist, report transfer, and offline or downtime behavior.
  • FDA source
  • Exact FDA submission
  • Checked 2026-09-03
Deployment and data flow
Ultrasound hardware or software with supported probes, host devices, licensed options, and network configuration.
  • FDA source
  • Exact FDA submission
  • Checked 2026-09-03
Security and privacy
Vendor documentation pending
  • Vendor confirmation
  • Exact FDA submission
  • Checked 2026-09-03

Public materials reviewed for this exact release do not establish the complete security posture. Request data-flow, identity, audit, encryption, retention, remote-access, vulnerability-management, backup, and incident-response evidence.

Training and support
Only qualified physicians, sonographers, and other trained ultrasound professionals should operate or interpret the product. Local onboarding should cover the exact release, supported population, limitations, failure examples, escalation, downtime, and competency documentation.
  • FDA source
  • Exact FDA submission
  • Checked 2026-09-03
Monitoring and change control
Monitor by exact hardware, software, model, and algorithm version; patient population; anatomy; protocol; operator; input quality; output edits or overrides; failed studies; repeat acquisition or rework; downstream impact; downtime; incidents; recalls; and updates. Track these product-specific limits: Use only supported upper-airway image inputs and measurements. The output supports physician evaluation and monitoring and is not a stand-alone diagnosis or airway-management decision.
  • FDA source
  • Exact FDA submission
  • Checked 2026-09-03

Release and scope verification

Map the installed model, build, options, population, anatomy, inputs, outputs, and enabled AI functions to K180867 before acceptance.

exact submission · checked 2026-09-03

Later product-family features are not evidence that this cleared release includes them.

Interoperability acceptance

Validate supported probes and host devices, patient matching, DICOM or local export, PACS measurements, worklist, report transfer, and offline or downtime behavior.

exact submission · checked 2026-09-03

Test representative identifiers, orientation, geometry, measurements, units, routing, failure handling, and round trips locally. The capability is derived from the exact FDA workflow and still requires local acceptance testing.

Clinical acceptance

Use a signed local test set for the supported population and workflow. Include common and difficult cases, exclusions, acquisition variation, failed or low-quality inputs, reviewer overrides, and downstream effects. Use only supported upper-airway image inputs and measurements. The output supports physician evaluation and monitoring and is not a stand-alone diagnosis or airway-management decision.

exact submission · checked 2026-09-03

Define stop-use, escalation, rollback, and revalidation triggers before production use.

Economic evaluation

Model capital and recurring cost against net staff time after review, throughput, repeat imaging or rework, room time, consumables, infrastructure, training, service, downtime, upgrade, and replacement costs.

product family · checked 2026-09-03

No exact-product price was found in the reviewed public material; vendor productivity claims are scenario inputs, not guaranteed local savings.

Lifecycle monitoring

Monitor by exact hardware, software, model, and algorithm version; patient population; anatomy; protocol; operator; input quality; output edits or overrides; failed studies; repeat acquisition or rework; downstream impact; downtime; incidents; recalls; and updates. Track these product-specific limits: Use only supported upper-airway image inputs and measurements. The output supports physician evaluation and monitoring and is not a stand-alone diagnosis or airway-management decision.

exact submission · checked 2026-09-03

Revalidate after material software, hardware, model, protocol, interface, or clinical-policy changes. The capability is derived from the exact FDA workflow and still requires local acceptance testing.

Evidence

Performance evidence

Metrics are shown only when they are tied to a source, endpoint, population, and tested product version. Candidate literature without exact product and version linkage is not shown as product evidence.

Evidence summary
K180867 reports software, ultrasonic-image processing, measurement, and validation testing for the upper-airway workflow. The public FDA summary does not establish a clinical outcome, sensitivity, or specificity value.
  • FDA source
  • Exact FDA submission
  • Checked 2026-09-03
Reported sensitivity
Not applicable
  • Not applicable
  • Not applicable
  • Checked 2026-09-03

Sensitivity is not the primary endpoint for this system, reconstruction, segmentation, guidance, or quantitative function. Use the task-specific evidence below.

Reported specificity
Not applicable
  • Not applicable
  • Not applicable
  • Checked 2026-09-03

Specificity is not the primary endpoint for this system, reconstruction, segmentation, guidance, or quantitative function. Use the task-specific evidence below.

No contextualized exact-version metric has completed evidence review. Regulatory-document values, when available, are shown above with their limitations.

K180867 FDA performance package for AmCAD-UO

  • DesignManufacturer ultrasonic-image processing, measurement, and software validation
  • PopulationPharyngeal and upper-airway ultrasound images for physician evaluation and monitoring
  • Scopeexact submission
  • Tested versionAmCAD-UO
  • IndependenceSponsor or vendor study

K180867

Manufacturer evidence submitted for FDA clearance or approval; local clinical, technical, and workflow acceptance remains necessary.

2 unlinked candidate evidence records are retained for source review and excluded from this evidence display.

Costs and setup

Budget and ongoing governance

These are common procurement questions; unknown values remain visible until a source supports them.

Pricing and total cost
Not established in reviewed sources
  • Reviewed sources checked
  • Exact FDA submission
  • Checked 2026-09-03

No public list price for the exact cleared configuration was found. Obtain a written quote separating hardware or license basis, implementation, interfaces, infrastructure, training, service, upgrades, renewal, consumables, and exit costs.

Reimbursement and coding
No separate named-product Medicare payment was identified in the reviewed CMS coverage material. Evaluate the product within the applicable imaging, procedural, or surgical service line and verify payer, site-of-service, and coding assumptions independently.
  • Public source
  • Not applicable
  • Checked 2026-09-03

No product-specific code

No separate named-product payment identified in reviewed public material

Centers for Medicare & Medicaid Services · United States

Build a local total-cost and value model; do not infer reimbursement from FDA clearance or approval.

Safety and lifecycle

Postmarket record

Recall and adverse-event records are shown only after product matching. Adverse-event reports do not establish incidence or causality.

Postmarket safety review
The 2026-09-02 openFDA device-recall snapshot contained no record matched to K180867 by exact submission identifier. This does not exclude product-family, later, or adverse-event information.
  • Public source
  • Exact FDA submission
  • Checked 2026-09-03

Exact-identifier review does not prove absence of all product-family safety signals.

Buyer worksheet

Open questions to take to the vendor

Open evaluation checklist

Research record

What has been checked

This audit distinguishes completed source review from fields that have not yet been researched.

Exact FDA record reviewedStatus
2026-09-20Last searched
28Fields reviewed
13Source classes checked
1Screened PubMed leads
1Screened trial leads
0Unreviewed FDA recall leads

The refreshed discovery snapshot contains 1 PubMed and 1 ClinicalTrials.gov candidate records. Discovery metadata alone does not establish exact tested-product, version, population, and endpoint applicability, so all candidates remain quarantined and none was promoted. The current discovery snapshot contains 1 PubMed and 1 ClinicalTrials.gov candidate records; its dated, count-matched human screening remains current. Unlinked candidates remain quarantined. Native FDA recall identifiers produced 0 postmarket candidate records; 0 have been reviewed (0 published, 0 rejected) and 0 remain unreviewed.

Candidate leads were screened against the exact product and tested version. Unlinked records remain quarantined.

Source classes: fda ai list, fda decision summary, fda decision material, peer reviewed literature, clinical trial registry, reimbursement policy, fda device recall, fda decision summary packet, literature index, trial registry, pubmed, clinical trials, openfda device recall

Sources & history

How this profile was documented

Open the ledger for source dates, scope, and research-record updates.

View source ledger and history

Source ledger

  1. FDA K180867: AmCAD-UO

    U.S. Food and Drug Administration - Published 2018-12-28 - Accessed 2026-09-19

    Scope: purpose, modality, anatomy, intendedUsers, input, output, clinicalUse

  2. Artificial Intelligence-Enabled Medical Devices

    U.S. Food and Drug Administration - Accessed 2026-08-31

    Scope: regulatoryIdentity, modalityContext

  3. PubMed biomedical literature index

    U.S. National Library of Medicine - Accessed 2026-09-01

    Scope: evidenceDiscovery

  4. ClinicalTrials.gov study registry

    U.S. National Library of Medicine - Accessed 2026-09-01

    Scope: evidenceDiscovery, studyStatus

  5. Medicare Coverage Database

    Centers for Medicare & Medicaid Services - Accessed 2026-09-01

    Scope: coverage, codingContext

  6. openFDA Device Recall API

    U.S. Food and Drug Administration - Accessed 2026-09-02

    Scope: recallDiscovery, nativeSubmissionMatching

  7. Efficacy of upper airway ultrasonography in detecting obstructive sleep apnea in the general population.

    U.S. National Library of Medicine - Accessed 2026-09-03

    Scope: evidenceStudies, productFamilyContext, evidenceDiscovery

  8. Tongue Morphology and Posterior Airway Space as Predictors of Response in Patientswith Hypoglossal Nerve Stimulation Therapy

    U.S. National Library of Medicine - Accessed 2026-09-03

    Scope: evidenceStudies, productFamilyContext, evidenceDiscovery

Research history

  1. K180867 FDA decision

    Regulatory record

    510(k)

  2. Source-review record updated

    Research record

    fda record reviewed

  3. Reader overview source-reviewed

    Editorial review

    Source-reviewed editorial overlay

Alternatives

Related tools to compare

FDA-cleared K251368

FETOLY

Diagnoly

FETOLY analyzes fetal ultrasound images and sequences to detect labeled fetal brain and heart views, assess image completeness or quality, and provide fetal biometric measurements...

Modality
Ultrasound
Anatomy
Fetal heart and fetal brain
Decision
2025-09-12
FDA-cleared K242130

Koios DS

Koios Medical, Inc.

Koios Decision Support (DS) is an artificial intelligence (AI)/machine learning (ML)-based computer-aided diagnosis (CADx) software device intended for use as an adjunct to...

Modality
Ultrasound
Anatomy
Breast
Decision
2024-11-15
FDA-cleared K240553

LVivo Software Application

DiA Imaging Analysis Ltd.

Non-invasive processing of ultrasound images to detect, measure, and calculate relevant medical parameters of structures and function in patients with suspected disease, with...

Modality
Ultrasound
Anatomy
Heart and cardiovascular structures, especially the left and right ventricles; a bladder-volume module is also described
Decision
2024-10-04