Input or output interoperability
DICOM is explicitly referenced in the described input, output, or workflow.
exact submission · checked 2026-09-01The model card does not establish every supported DICOM object, transfer method, or local interface.
FDA-cleared profile
Koios Medical, Inc.
Authorized purpose: Koios Decision Support (DS) is an artificial intelligence (AI)/machine learning (ML)-based computer-aided diagnosis (CADx) software device intended for use as an adjunct to diagnostic ultrasound examinations of lesions or nodules suspicious for breast or thyroid cancer. Koios DS allows the user to select or confirm regions of interest (ROIs) within an image representing a single lesion or nodule to be analyzed. The software then automatically characterizes the selected image data to generate an AI/MLderived cancer risk assessment and selects applicable lexicon-based descriptors designed to improve overall diagnostic accuracy as well as reduce interpreting physician variability. Koios DS software may also be used as an image viewer of multi-modality digital images, including ultrasound and mammography. The software includes tools that allow users to adjust, measure and document images, and output into a structured report. Koios DS software is designed to assist trained interpreting physicians in analyzing the breast ultrasound images of adult (>= 22 years) female patients with soft tissue breast lesions and/or thyroid ultrasounds of all adult (>= 22 years) patients with thyroid nodules suspicious for cancer. When utilized by an interpreting physician who has completed the prescribed training, this device provides information that may be useful in recommending appropriate clinical management.
Product overview
Authorized purpose: Koios Decision Support (DS) is an artificial intelligence (AI)/machine learning (ML)-based computer-aided diagnosis (CADx) software device intended for use as an adjunct to diagnostic ultrasound examinations of lesions or nodules suspicious for breast or thyroid cancer. Koios DS allows the user to select or confirm regions of interest (ROIs) within an image representing a single lesion or nodule to be analyzed. The software then automatically characterizes the selected image data to generate an AI/MLderived cancer risk assessment and selects applicable lexicon-based descriptors designed to improve overall diagnostic accuracy as well as reduce interpreting physician variability. Koios DS software may also be used as an image viewer of multi-modality digital images, including ultrasound and mammography. The software includes tools that allow users to adjust, measure and document images, and output into a structured report. Koios DS software is designed to assist trained interpreting physicians in analyzing the breast ultrasound images of adult (>= 22 years) female patients with soft tissue breast lesions and/or thyroid ultrasounds of all adult (>= 22 years) patients with thyroid nodules suspicious for cancer. When utilized by an interpreting physician who has completed the prescribed training, this device provides information that may be useful in recommending appropriate clinical management.
Overview status: Source-reviewed overview
Clinical role: Koios Decision Support (DS) is an artificial intelligence (AI)/machine learning (ML)-based computer-aided diagnosis (CADx) software device intended for use as an adjunct to diagnostic ultrasound examinations of lesions or nodules suspicious for breast or thyroid cancer. Koios DS allows the user to select or confirm regions of interest (ROIs) within an image representing a single lesion or nodule to be analyzed. The software then automatically characterizes the selected image data to generate an AI/MLderived cancer risk assessment and selects applicable lexicon-based descriptors designed to improve overall diagnostic accuracy as well as reduce interpreting physician variability. Koios DS software may also be used as an image viewer of multi-modality digital images, including ultrasound and mammography. The software includes tools that allow users to adjust, measure and document images, and output into a structured report. Koios DS software is designed to assist trained interpreting physicians in analyzing the breast ultrasound images of adult (>= 22 years) female patients with soft tissue breast lesions and/or thyroid ultrasounds of all adult (>= 22 years) patients with thyroid nodules suspicious for cancer. When utilized by an interpreting physician who has completed the prescribed training, this device provides information that may be useful in recommending appropriate clinical management.
Evidence from the reviewed source record: Study type: Reader Study. Cases: 900. Reference standard: null. Reader-study cases: 900. Readers: 15. Reader-study sensitivity: 97.6%. Reader-study specificity: 63.2%
Clinical details
Start with the authorized purpose, then verify how it fits your service line and reading workflow.
Clinical-use display mirrors the exact FDA-supported purpose reconciled from the decision-summary packet.
The exact user-profile section provides this trained-professional boundary rather than the current radiologist-only wording.
Patient-population text reported in the exact-submission ACR model card; institutional setting may still require vendor confirmation.
Conservative normalization of explicit wording in an exact-submission source.
The exact packet supports DICOM-compliant digital files and both breast and thyroid ultrasound image input; the current breast-only and consult-instruction wording is not retained.
The exact indications provide the general risk-assessment, descriptor, image-tool, and structured-report output; the current breast-only output wording is incomplete.
The exact packet provides these use limitations; the current non-DICOM/non-ultrasound, severe-artifact, and modality-exclusion wording is not the packet's limitation text.
Regulatory identity
The FDA listing establishes the regulatory identity. It does not by itself establish local workflow fit, pricing, security, or performance in your environment.
Exact FDA decision-summary packet reviewed on 2026-09-19; existing wording is supported without expansion.
The exact indications cover adult female breast lesions and adult thyroid nodules; the current breast-only anatomy is too narrow. Controlled directory display reconciled from exact FDA wording: Breast and thyroid. -> Breast.
Implementation
Use these fields to structure a vendor demo, security review, and implementation estimate.
Interoperability terms explicitly reported in the exact-submission ACR model card; interface versions and local compatibility still require confirmation.
Deployment category preserved from the prior exact-submission review; hosting region, data flow, and current commercial configuration still require vendor confirmation.
Exact-release security controls, data retention, hosting boundaries, and scoped assurance documentation require vendor confirmation.
Current training prerequisites, competency checks, and support commitments for the exact configuration require vendor confirmation.
Current drift, quality, uptime, alert, escalation, and incident-response commitments for the exact configuration require vendor confirmation.
DICOM is explicitly referenced in the described input, output, or workflow.
exact submission · checked 2026-09-01The model card does not establish every supported DICOM object, transfer method, or local interface.
ACR AI Central provides an exact-submission model card for Koios DS; FDA labeling remains controlling for clinical use, limitations, and performance.
exact submission · checked 2026-09-08Evidence
Metrics are shown only when they are tied to a source, endpoint, population, and tested product version. Candidate literature without exact product and version linkage is not shown as product evidence.
Exact FDA decision-summary packet reviewed on 2026-09-19; existing wording is supported without expansion.
Values reported in the exact-submission materials. Consult the linked source for endpoint, threshold, population, and confidence interval before comparison.
Values reported in the exact-submission materials. Consult the linked source for endpoint, threshold, population, and confidence interval before comparison.
No contextualized exact-version metric has completed evidence review. Regulatory-document values, when available, are shown above with their limitations.
K242130
ACR AI Central summarizes the regulatory study; consult the exact FDA materials before comparative use.
Costs and setup
These are common procurement questions; unknown values remain visible until a source supports them.
No public price or quote for the exact K242130 configuration was established in this review.
No exact-product payer policy, coding instruction, or payment determination was established; eligibility must be evaluated by payer, site of service, and use case.
Safety and lifecycle
Recall and adverse-event records are shown only after product matching. Adverse-event reports do not establish incidence or causality.
Buyer worksheet
Research record
This audit distinguishes completed source review from fields that have not yet been researched.
The refreshed discovery snapshot contains 14 PubMed and 0 ClinicalTrials.gov candidate records. Discovery metadata alone does not establish exact tested-product, version, population, and endpoint applicability, so all candidates remain quarantined and none was promoted. The current discovery snapshot contains 14 PubMed and 0 ClinicalTrials.gov candidate records; its dated, count-matched human screening remains current. Unlinked candidates remain quarantined. Native FDA recall identifiers produced 0 postmarket candidate records; 0 have been reviewed (0 published, 0 rejected) and 0 remain unreviewed.
Candidate leads were screened against the exact product and tested version. Unlinked records remain quarantined.
Source classes: fda ai list, fda decision summary, acr ai central product, fda device recall, literature index, trial registry, fda decision summary packet, pubmed, clinical trials, openfda device recall
Sources & history
Open the ledger for source dates, scope, and research-record updates.
Scope: identity, clinicalUse, modality, anatomy, workflow, evidence, implementation, purpose, evidenceSummary, intendedUsers, input, output, limitations
Scope: regulatoryIdentity, modalityContext
Scope: intendedUsers, careSetting, output, limitations, evidenceSummary, integration, anatomy, evidenceStudies, implementationCapabilities
Scope: evidenceDiscovery
Scope: evidenceDiscovery, studyStatus
Scope: recallDiscovery, nativeSubmissionMatching
Scope: postmarketSafety
Regulatory record
510(k)
Research record
fda record reviewed
Editorial review
Source-reviewed editorial overlay
Alternatives
Koios Medical, Inc.
Koios DS is an artificial intelligence (AI)/machine learning (ML)-based computer-aided diagnosis (CADx) software device intended for use as an adjunct to diagnostic ultrasound...
ClearView Diagnostics Inc.
ClearView cCAD is a software application designed to assist skilled physicians in analyzing breast ultrasound images. It automatically classifies shape and orientation...
Diagnoly
FETOLY analyzes fetal ultrasound images and sequences to detect labeled fetal brain and heart views, assess image completeness or quality, and provide fetal biometric measurements...
DeepEcho
Detect standard fetal biometry views and assist fetal biometry measurements during prenatal ultrasound acquisition and interpretation.