- Integration
- Standards-based DICOM/PACS integration was identified in the FDA submission materials; compatibility with a specific PACS, RIS, EHR, or orchestrator requires confirmation.
Public source Exact FDA submission Checked 2026-08-13
Normalized from the prior exact-submission review. Confirm interface versions and local compatibility during technical evaluation.
- Deployment and data flow
- The exact FDA package describes a web-based standalone application for the AIBOLIT 3D+ release; verify current hosting, site configuration, and service responsibility locally.
FDA source Exact FDA submission Checked 2026-09-04
This is the release-level boundary described in the exact FDA package; current hosting, contracts, security, availability, and site configuration remain separate evidence.
- Security and privacy
- Not established in reviewed sources
Reviewed sources checked Exact FDA submission Checked 2026-09-04
Public materials reviewed for this exact release do not establish the complete security posture. Request data-flow, identity, audit, encryption, retention, remote-access, vulnerability-management, backup, and incident-response evidence.
- Training and support
- Only qualified surgeons, radiologists, and other trained clinical professionals for the labeled procedure should operate or interpret the product. Local onboarding should cover the exact release, supported population, limitations, failure examples, escalation, downtime, and competency documentation.
FDA source Exact FDA submission Checked 2026-09-04
- Monitoring and change control
- Monitor K211443 by exact hardware, software, model, and algorithm version; patient population; anatomy; protocol; operator; input quality; output edits or overrides; failed studies; repeat acquisition or rework; downstream impact; downtime; incidents; recalls; and updates. Track these product-specific limits: Displays and models support planning, training, patient information, or intraoperative display but do not replace professional judgment or procedural controls.
FDA source Exact FDA submission Checked 2026-09-04
Monitoring guidance is buyer-facing implementation guidance derived from the exact cleared scope; it is not a claim that the FDA package provides a live monitoring service.
Release and scope verification
Map installed model, build, options, population, anatomy, inputs, outputs, and enabled functions to K211443 before acceptance.
exact submission · checked 2026-09-04 Later product-family features are not evidence that this cleared release includes them.
Deployment boundary
The exact FDA package describes a web-based standalone application for the AIBOLIT 3D+ release; verify current hosting, site configuration, and service responsibility locally.
exact submission · checked 2026-09-04 FDA-described deployment boundaries do not establish current hosting contracts, security controls, uptime, or local qualification.
Interoperability acceptance
The exact public integration contract remains incomplete; establish and test supported input, output, identity, routing, archive, and downtime behavior locally.
exact submission · checked 2026-09-04 Test representative identifiers, orientation, geometry, measurements, units, routing, failure handling, and round trips locally.
Clinical acceptance
Use a signed local test set for the supported population and workflow. Include common and difficult cases, exclusions, acquisition variation, failed or low-quality inputs, reviewer overrides, and downstream effects. Displays and models support planning, training, patient information, or intraoperative display but do not replace professional judgment or procedural controls.
exact submission · checked 2026-09-04 Define stop-use, escalation, rollback, and revalidation triggers before production use.
Economic evaluation
Model capital and recurring cost against net staff time after review, throughput, repeat imaging or rework, room time, consumables, infrastructure, training, service, downtime, upgrade, and replacement costs.
product family · checked 2026-09-04 No exact-product price was found in the reviewed public material; productivity or value claims require local evidence.
Lifecycle monitoring
Monitor K211443 by exact hardware, software, model, and algorithm version; patient population; anatomy; protocol; operator; input quality; output edits or overrides; failed studies; repeat acquisition or rework; downstream impact; downtime; incidents; recalls; and updates. Track these product-specific limits: Displays and models support planning, training, patient information, or intraoperative display but do not replace professional judgment or procedural controls.
exact submission · checked 2026-09-04 Revalidate after material software, hardware, model, protocol, interface, or clinical-policy changes. medical-image surgical-planning software limits remain submission-specific.