FDA-cleared profile

SubtleHD-CT (1.x)

Subtle Medical, Inc.

Authorized purpose: Process and enhance CT images from any CT scanner manufacturer or model as an adjunct to the original reconstructed image.

Evidence status: each field states its source quality, applicability, and review date. Research pending, information not established, and vendor documentation pending remain distinct outcomes.

Product overview

Start with the essentials

Authorized purpose: Process and enhance CT images from any CT scanner manufacturer or model as an adjunct to the original reconstructed image.

Overview status: Source-reviewed overview

Clinical takeaway

Clinical role: Process and enhance CT images from any CT scanner manufacturer or model as an adjunct to the original reconstructed image.

Evidence takeaway

Evidence from the reviewed source record: FDA K254120 reports phantom performance validation using ACR, Digital CatPhan 600, and Mercury 4.0 phantoms plus a 270-case retrospective reader study. Phantom endpoints included detectability index, noise magnitude, NPS, CT-number accuracy, non-uniformity, and TTF, all reported as passing their stated criteria. Reader endpoints were diagnostic utility (average Likert score >=3) and artifact presence (average score >=2); no sensitivity/specificity or disease-detection accuracy was reported.

Clinical details

What this tool is for

Start with the authorized purpose, then verify how it fits your service line and reading workflow.

Exact purpose
Process and enhance CT images from any CT scanner manufacturer or model as an adjunct to the original reconstructed image.
  • FDA source
  • Exact FDA submission
  • Checked 2026-09-08
Intended users
Radiologists.
  • FDA source
  • Exact FDA submission
  • Checked 2026-09-08
Care setting and population
Medical facilities including hospitals, clinics, and imaging centers; the reader dataset included adult and pediatric subjects.
  • FDA source
  • Exact FDA submission
  • Checked 2026-09-08
Workflow role
Background post-processing image enhancement with adjunctive radiologist review.
  • FDA source
  • Exact FDA submission
  • Checked 2026-09-08
Required input
Primary reconstructed DICOM CT images sent by a technologist through a compatible MDDS; FBP primary reconstructions at standard or higher dose were quantitatively validated. The packet also includes varied scanners, anatomies, contrast, reconstruction methods, and slice thicknesses, but warns that IR/DL reconstruction performance may be unknown.
  • FDA source
  • Exact FDA submission
  • Checked 2026-09-08
Output and human action
Enhanced DICOM CT images returned through the compatible MDDS to PACS or another DICOM node; enhanced images coexist with the original reconstructed images; no user interface.
  • FDA source
  • Exact FDA submission
  • Checked 2026-09-08
Limitations
Output interpretation is adjunctive to the original reconstructed image. Use with iterative reconstruction or deep-learning reconstructions may have unknown performance; advanced third-party post-processing or specialized non-standard filtering was not specifically characterized, and direct primary scanner reconstructions are recommended.
  • FDA source
  • Exact FDA submission
  • Checked 2026-09-08

Regulatory identity

FDA record and catalog context

The FDA listing establishes the regulatory identity. It does not by itself establish local workflow fit, pricing, security, or performance in your environment.

FDA submission
K254120
  • FDA source
  • Exact FDA submission
  • Checked 2026-08-31
Modality
CT/CTA
  • FDA source
  • Exact FDA submission
  • Checked 2026-09-08
Anatomy
Multiple CT anatomies: abdomen, C-spine, cardiac, chest, chest-abdomen-pelvis, head, head/neck, L-spine, lower extremity, MSK, T-spine, and upper extremity.
  • FDA source
  • Exact FDA submission
  • Checked 2026-09-08
Clearance type
510(k)
  • FDA source
  • Exact FDA submission
  • Checked 2026-08-31
Decision date
2026-05-15
  • FDA source
  • Exact FDA submission
  • Checked 2026-08-31
FDA status
FDA-cleared
  • FDA source
  • Exact FDA submission
  • Checked 2026-08-31

Implementation

Questions for IT, informatics, and operations

Use these fields to structure a vendor demo, security review, and implementation estimate.

Integration
Technologist routes the study from the CT scanner to a compatible MDDS via DICOM; the MDDS supplies images to SubtleHD-CT and returns enhanced images to PACS or another DICOM node using an AE Title.
  • FDA source
  • Exact FDA submission
  • Checked 2026-09-08
Deployment and data flow
Vendor documentation pending
  • Vendor confirmation
  • Exact FDA submission
  • Checked 2026-09-08

The reviewed sources do not establish the current exact-release hosting topology, data flow, region, tenancy, or disaster-recovery configuration.

Security and privacy
Vendor documentation pending
  • Vendor confirmation
  • Exact FDA submission
  • Checked 2026-09-08

Exact-release security controls, data retention, hosting boundaries, and scoped assurance documentation require vendor confirmation.

Training and support
Vendor documentation pending
  • Vendor confirmation
  • Exact FDA submission
  • Checked 2026-09-08

Current training prerequisites, competency checks, and support commitments for the exact configuration require vendor confirmation.

Monitoring and change control
Vendor documentation pending
  • Vendor confirmation
  • Exact FDA submission
  • Checked 2026-09-08

Current drift, quality, uptime, alert, escalation, and incident-response commitments for the exact configuration require vendor confirmation.

Input or output interoperability

DICOM is explicitly referenced in the described input, output, or workflow.

exact submission · checked 2026-09-01

The model card does not establish every supported DICOM object, transfer method, or local interface.

Result destination

PACS is explicitly referenced as a result destination.

exact submission · checked 2026-09-01

Confirm supported products, versions, routing behavior, and display requirements during local evaluation.

ACR exact-submission catalog context

ACR AI Central provides an exact-submission model card for SubtleHD-CT (1.x); FDA labeling remains controlling for clinical use, limitations, and performance.

exact submission · checked 2026-09-08

Evidence

Performance evidence

Metrics are shown only when they are tied to a source, endpoint, population, and tested product version. Candidate literature without exact product and version linkage is not shown as product evidence.

Evidence summary
FDA K254120 reports phantom performance validation using ACR, Digital CatPhan 600, and Mercury 4.0 phantoms plus a 270-case retrospective reader study. Phantom endpoints included detectability index, noise magnitude, NPS, CT-number accuracy, non-uniformity, and TTF, all reported as passing their stated criteria. Reader endpoints were diagnostic utility (average Likert score >=3) and artifact presence (average score >=2); no sensitivity/specificity or disease-detection accuracy was reported.
  • FDA source
  • Exact FDA submission
  • Checked 2026-09-08
Reported sensitivity
Research pending
  • Needs research
  • Exact FDA submission
  • Checked 2026-08-31

This field has not been curated yet.

Reported specificity
Research pending
  • Needs research
  • Exact FDA submission
  • Checked 2026-08-31

This field has not been curated yet.

No contextualized exact-version metric has completed evidence review. Regulatory-document values, when available, are shown above with their limitations.

SubtleHD-CT (1.x) regulatory performance study summary

  • DesignReader Study
  • PopulationAdult and Pediatric
  • Scopeexact submission
  • Tested versionExact product version not reported; regulatory study summarized for FDA submission K254120
  • IndependenceIndependence not established

K254120

ACR AI Central summarizes the regulatory study; consult the exact FDA materials before comparative use.

Costs and setup

Budget and ongoing governance

These are common procurement questions; unknown values remain visible until a source supports them.

Pricing and total cost
Vendor documentation pending
  • Vendor confirmation
  • Exact FDA submission
  • Checked 2026-09-08

No public price or quote for the exact K254120 configuration was established in this review.

Reimbursement and coding
Not established in reviewed sources
  • Reviewed sources checked
  • Exact FDA submission
  • Checked 2026-09-08

No exact-product payer policy, coding instruction, or payment determination was established; eligibility must be evaluated by payer, site of service, and use case.

Safety and lifecycle

Postmarket record

Recall and adverse-event records are shown only after product matching. Adverse-event reports do not establish incidence or causality.

Postmarket safety review
The exact-identifier FDA recall query returned no native recall record for K254120. This limited result does not establish absence of recalls or other safety information and does not cover later versions, family records, MAUDE reports, corrections, or field notices.
  • Public source
  • Exact FDA submission
  • Checked 2026-09-08

Buyer worksheet

Open questions to take to the vendor

Open evaluation checklist

Research record

What has been checked

This audit distinguishes completed source review from fields that have not yet been researched.

Exact FDA record reviewedStatus
2026-09-20Last searched
23Fields reviewed
9Source classes checked
0Screened PubMed leads
0Screened trial leads
0Unreviewed FDA recall leads

The refreshed discovery snapshot contains no PubMed or ClinicalTrials.gov candidates; no external evidence was promoted. The current discovery snapshot contains 0 PubMed and 0 ClinicalTrials.gov candidate records; its dated, count-matched human screening remains current. Unlinked candidates remain quarantined. Native FDA recall identifiers produced 0 postmarket candidate records; 0 have been reviewed (0 published, 0 rejected) and 0 remain unreviewed.

Candidate leads were screened against the exact product and tested version. Unlinked records remain quarantined.

Source classes: fda ai list, acr ai central product, fda decision summary, fda device recall, literature index, trial registry, pubmed, clinical trials, openfda device recall

Sources & history

How this profile was documented

Open the ledger for source dates, scope, and research-record updates.

View source ledger and history

Source ledger

  1. FDA K254120: SubtleHD-CT (1.x)

    U.S. Food and Drug Administration - Published 2026-05-15 - Accessed 2026-09-08

    Scope: identity, clinicalUse, modality, anatomy, workflow, evidence, implementation

  2. Artificial Intelligence-Enabled Medical Devices

    U.S. Food and Drug Administration - Accessed 2026-08-31

    Scope: regulatoryIdentity, modalityContext

  3. SubtleHD-CT (1.x) model card (K254120)

    American College of Radiology - Published 2026-08-17 - Accessed 2026-09-01

    Scope: intendedUsers, careSetting, output, limitations, evidenceSummary, integration, anatomy, evidenceStudies, implementationCapabilities

  4. PubMed biomedical literature index

    U.S. National Library of Medicine - Accessed 2026-09-01

    Scope: evidenceDiscovery

  5. ClinicalTrials.gov study registry

    U.S. National Library of Medicine - Accessed 2026-09-01

    Scope: evidenceDiscovery, studyStatus

  6. openFDA Device Recall API

    U.S. Food and Drug Administration - Accessed 2026-09-02

    Scope: recallDiscovery, nativeSubmissionMatching

  7. openFDA exact recall query for K254120

    U.S. Food and Drug Administration - Accessed 2026-09-08

    Scope: postmarketSafety

Research history

  1. K254120 FDA decision

    Regulatory record

    510(k)

  2. Source-review record updated

    Research record

    fda record reviewed

  3. Reader overview source-reviewed

    Editorial review

    Source-reviewed editorial overlay

Alternatives

Related tools to compare

FDA-cleared K252029

AI-CVD

HeartLung Corporation

AI-CVD provides automated quantitative CT-derived anatomical and density measurements for clinician review, including calcium scores, cardiac and vascular measurements, lung and...

Modality
CT/CTA
Anatomy
Chest, abdomen, heart, lungs, liver, aorta, pulmonary artery, bone, muscle, and fat
Decision
2025-12-19
FDA-cleared K242624

Medical Image Post-processing Software (uOmnispace.CT)

Shanghai United Imaging Healthcare Co., Ltd.

uOmnispace.CT provides healthcare institutions with tools to view, manipulate, evaluate, and analyze medical CT images, including colon, lung, vessel, brain, cardiac, liver, rib,...

Modality
CT/CTA
Anatomy
Colon, lungs and airway, vessels, brain, heart, liver, ribs, spine, and other CT regions
Decision
2025-05-14
FDA-cleared K233209

uOmnispace.CT

Shanghai United Imaging Healthcare Co., Ltd.

uOmnispace.CT is software for viewing, manipulating, evaluating, and analyzing medical images within healthcare institutions. The FDA indication lists colon visualization, dental...

Modality
CT/CTA
Anatomy
Colon, jaw, lungs, airways, brain, heart, vessels, liver, spine, ribs, and other labeled CT regions
Decision
2024-05-17