Authorized purpose: Automatic segmentation and reporting of cardiac function measurements from 1.5T and 3T MR images to support clinical decision-making; results are not intended for standalone clinical decision-making.
Evidence status: each field states its source quality, applicability, and review date. Research pending, information not established, and vendor documentation pending remain distinct outcomes.
Product overview
Start with the essentials
Authorized purpose: Automatic segmentation and reporting of cardiac function measurements from 1.5T and 3T MR images to support clinical decision-making; results are not intended for standalone clinical decision-making.
Overview status: Source-reviewed overview
What does this software do?Authorized purpose: Automatic segmentation and reporting of cardiac function measurements from 1.5T and 3T MR images to support clinical decision-making; results are not intended for standalone clinical decision-making.
Which images or clinical context are in scope?Modality: MRI Anatomy or clinical context: Heart, including left and right ventricles, myocardium, and cardiac chambers Input: Cardiac MR images from 1.5T and 3T scanners, including multi-slice MR data received through a DICOM viewer that provides the user interface and connection to a PACS or scanner.
Who uses it?Intended users: The user incorporating AI4CMR into a DICOM application of choice
What does the software produce?Output: Anatomical and tissue segmentation; LV/RV stroke volume, cardiac output, ejection fraction, end-diastolic volume, end-systolic volume, and myocardial mass; derived indices when required patient height and weight are present in DICOM; and report or DICOM Secondary Capture outputs.
What is its most important limitation?Key limitation: Results are not for standalone clinical decision-making, and the user is responsible for implementing the DICOM viewer user interface. Indices derived from height and weight are available only when those values are included in the DICOM data. The FDA evidence uses small bench and retrospective MRMC datasets across specified 1.5T/3T scanners and establishes measurement agreement and segmentation endpoints rather than autonomous diagnosis.
Clinical takeaway
Clinical role: Automatic segmentation and reporting of cardiac function measurements from 1.5T and 3T MR images to support clinical decision-making; results are not intended for standalone clinical decision-making.
Evidence takeaway
Evidence from the reviewed source record: FDA bench testing used 15 CMR cases annotated by seven independent expert readers across 1.5T and 3T Siemens, GE, and Philips scanners; average myocardium segmentation Dice similarity coefficient was 0.72. Reported measurement agreement included LV EF bias 3.87 (SD 5.74), LV ICC 0.96; RV EF bias 7.80 (7.32), RV ICC 0.81; LV EDV bias 8.66 (17.28), LV ICC 0.99; RV EDV bias 8.36 (15.59), RV ICC 0.96; LV ESV bias -2.90 (17.52), LV ICC 0.99; RV ESV bias -9.08 (13.83), RV ICC 0.95; and LV myocardial-mass bias 2.45 (18.04), ICC 0.96. The retrospective MRMC clinical performance assessment used 146 CMR cases and two expert readers to evaluate agreement with manual segmentation and measurements; the reviewed text does not provide a single diagnostic sensitivity or specificity result.
Clinical details
What this tool is for
Start with the authorized purpose, then verify how it fits your service line and reading workflow.
Exact purpose
Automatic segmentation and reporting of cardiac function measurements from 1.5T and 3T MR images to support clinical decision-making; results are not intended for standalone clinical decision-making.
Post-processing cardiac MR segmentation and quantification through a plug-in to a third-party DICOM viewer, with results made available to the user for review and reporting.
Cardiac MR images from 1.5T and 3T scanners, including multi-slice MR data received through a DICOM viewer that provides the user interface and connection to a PACS or scanner.
Anatomical and tissue segmentation; LV/RV stroke volume, cardiac output, ejection fraction, end-diastolic volume, end-systolic volume, and myocardial mass; derived indices when required patient height and weight are present in DICOM; and report or DICOM Secondary Capture outputs.
Results are not for standalone clinical decision-making, and the user is responsible for implementing the DICOM viewer user interface. Indices derived from height and weight are available only when those values are included in the DICOM data. The FDA evidence uses small bench and retrospective MRMC datasets across specified 1.5T/3T scanners and establishes measurement agreement and segmentation endpoints rather than autonomous diagnosis.
The FDA listing establishes the regulatory identity. It does not by itself establish local workflow fit, pricing, security, or performance in your environment.
Use these fields to structure a vendor demo, security review, and implementation estimate.
Integration
AI4CMR is described as a cloud-hosted service implemented as a plug-in to any third-party DICOM viewer; the viewer serves as the user interface and the interface to a PACS or scanner. DICOM input and report/DICOM Secondary Capture output are described, but specific PACS, RIS, EHR, interface versions, and current local compatibility are not established.
Deployment category preserved from the prior exact-submission review; hosting region, data flow, and current commercial configuration still require vendor confirmation.
ACR AI Central provides an exact-submission model card for AI4CMR v1.0; FDA labeling remains controlling for clinical use, limitations, and performance.
Metrics are shown only when they are tied to a source, endpoint, population, and tested product version. Candidate literature without exact product and version linkage is not shown as product evidence.
Evidence summary
FDA bench testing used 15 CMR cases annotated by seven independent expert readers across 1.5T and 3T Siemens, GE, and Philips scanners; average myocardium segmentation Dice similarity coefficient was 0.72. Reported measurement agreement included LV EF bias 3.87 (SD 5.74), LV ICC 0.96; RV EF bias 7.80 (7.32), RV ICC 0.81; LV EDV bias 8.66 (17.28), LV ICC 0.99; RV EDV bias 8.36 (15.59), RV ICC 0.96; LV ESV bias -2.90 (17.52), LV ICC 0.99; RV ESV bias -9.08 (13.83), RV ICC 0.95; and LV myocardial-mass bias 2.45 (18.04), ICC 0.96. The retrospective MRMC clinical performance assessment used 146 CMR cases and two expert readers to evaluate agreement with manual segmentation and measurements; the reviewed text does not provide a single diagnostic sensitivity or specificity result.
No contextualized exact-version metric has completed evidence review. Regulatory-document values, when available, are shown above with their limitations.
AI4CMR v1.0 regulatory performance study summary
DesignStand-alone performance and reader study (ACR AI Central category)
PopulationPopulation described in the exact-submission ACR model card
Scopeexact submission
Tested versionExact product version not reported; regulatory study summarized for FDA submission K220624
Samplen=15
IndependenceIndependence not established
K220624
ACR AI Central summarizes the regulatory study; consult the exact FDA materials before comparative use.
These are common procurement questions; unknown values remain visible until a source supports them.
Pricing and total cost
Vendor documentation pending
Vendor confirmation
Exact FDA submission
Checked 2026-09-08
No public price or quote for the exact K220624 configuration was established in this review.
Reimbursement and coding
Not established in reviewed sources
Reviewed sources checked
Exact FDA submission
Checked 2026-09-08
No exact-product payer policy, coding instruction, or payment determination was established; eligibility must be evaluated by payer, site of service, and use case.
Safety and lifecycle
Postmarket record
Recall and adverse-event records are shown only after product matching. Adverse-event reports do not establish incidence or causality.
Postmarket safety review
The exact-identifier FDA recall query returned no native recall record for K220624. This limited result does not establish absence of recalls or other safety information and does not cover later versions, family records, MAUDE reports, corrections, or field notices.
Verify security and privacy controls: Exact-release security controls, data retention, hosting boundaries, and scoped assurance documentation require vendor confirmation.
Verify training: Current training prerequisites, competency checks, and support commitments for the exact configuration require vendor confirmation.
Verify pricing and total cost: No public price or quote for the exact K220624 configuration was established in this review.
Verify reimbursement and coding relevance: No exact-product payer policy, coding instruction, or payment determination was established; eligibility must be evaluated by payer, site of service, and use case.
Verify local validation and lifecycle monitoring: Current drift, quality, uptime, alert, escalation, and incident-response commitments for the exact configuration require vendor confirmation.
This audit distinguishes completed source review from fields that have not yet been researched.
Exact FDA record reviewedStatus
2026-09-20Last searched
22Fields reviewed
9Source classes checked
0Screened PubMed leads
0Screened trial leads
0Unreviewed FDA recall leads
The refreshed discovery snapshot contains no PubMed or ClinicalTrials.gov candidates; no external evidence was promoted. The current discovery snapshot contains 0 PubMed and 0 ClinicalTrials.gov candidate records; its dated, count-matched human screening remains current. Unlinked candidates remain quarantined. Native FDA recall identifiers produced 0 postmarket candidate records; 0 have been reviewed (0 published, 0 rejected) and 0 remain unreviewed.
Candidate leads were screened against the exact product and tested version. Unlinked records remain quarantined.
Source classes: fda ai list, fda decision summary, acr ai central product, fda device recall, literature index, trial registry, pubmed, clinical trials, openfda device recall
Sources & history
How this profile was documented
Open the ledger for source dates, scope, and research-record updates.
View source ledger and history7 sources - 3 history items
Myomics assists qualified medical professionals with viewing, post-processing and qualitative/quantitative evaluation of 3T cardiovascular MR images in DICOM format, including...
Provide cardiac-chamber segmentations for trained healthcare professionals reviewing adult cardiac MR to assist diagnosis or treatment planning; the physician makes final...
Modality
MRI
Anatomy
Cardiac chambers: left-ventricular myocardium and chamber, and right-ventricular chamber for the Cine-ax component; left-ventricular myocardium and chamber for the De-ax component.