FDA-cleared profile

VERITON CT 300 Series Digital SPECT/CT System (VERITON CT 316/364); VERITON CT 400 Series Digital SPECT/CT System (VERITON CT 416/464)

Spectrum Dynamics Medical, Ltd.

Authorized purpose: VERITON CT 300/400 Series combines SPECT and CT for detection, localization, diagnosis, staging, restaging, organ-function assessment, therapy planning, guidance, and monitoring. Optional VERITAS.AI applies locked noise-reduction models to reconstructed SPECT images.

Evidence status: each field states its source quality, applicability, and review date. Research pending, information not established, and vendor documentation pending remain distinct outcomes.

Product overview

Start with the essentials

Authorized purpose: VERITON CT 300/400 Series combines SPECT and CT for detection, localization, diagnosis, staging, restaging, organ-function assessment, therapy planning, guidance, and monitoring. Optional VERITAS.AI applies locked noise-reduction models to reconstructed SPECT images.

Overview status: Source-reviewed overview

Clinical takeaway

Clinical role: VERITON CT 300/400 Series combines SPECT and CT for detection, localization, diagnosis, staging, restaging, organ-function assessment, therapy planning, guidance, and monitoring. Optional VERITAS.AI applies locked noise-reduction models to reconstructed SPECT images.

Evidence takeaway

Evidence from the reviewed source record: Exact-submission testing used a 30-patient held-out evaluation set and reported strong lesion-signal preservation with lower background variability after noise reduction. The evidence is manufacturer generated and must be supplemented with local quantitative and reader acceptance.

Clinical details

What this tool is for

Start with the authorized purpose, then verify how it fits your service line and reading workflow.

Exact purpose
VERITON CT 300/400 Series combines SPECT and CT for detection, localization, diagnosis, staging, restaging, organ-function assessment, therapy planning, guidance, and monitoring. Optional VERITAS.AI applies locked noise-reduction models to reconstructed SPECT images.
  • FDA source
  • Exact FDA submission
  • Checked 2026-09-04

Added in P2 round17 from the exact FDA decision material; later product-family claims remain separate.

Intended users
Qualified nuclear-medicine physicians, radiologists, technologists, and other trained healthcare professionals.
  • FDA source
  • Exact FDA submission
  • Checked 2026-09-03
Care setting and population
Hospital and outpatient nuclear-medicine and theranostics departments.
  • FDA source
  • Exact FDA submission
  • Checked 2026-09-03
Workflow role
Hybrid SPECT/CT acquisition, reconstruction, quantification, diagnostic review, and therapy-planning or monitoring support.
  • Public source
  • Exact FDA submission
  • Checked 2026-09-03
Required input
SPECT projection data and CT acquisition data; VERITAS.AI operates on reconstructed SPECT images.
  • FDA source
  • Exact FDA submission
  • Checked 2026-09-03
Output and human action
SPECT, CT, and fused images plus optional noise-reduced SPECT images and quantitative information.
  • FDA source
  • Exact FDA submission
  • Checked 2026-09-03
Limitations
VERITAS.AI preserves the original reconstruction and is not authorized to change raw data, quantitative values, or dosimetry. Bone-IQ.AI, Thera-IQ.AI, and MIBG-IQ.AI must be used only in their labeled tracer and workflow scopes.
  • FDA source
  • Exact FDA submission
  • Checked 2026-09-03

Regulatory identity

FDA record and catalog context

The FDA listing establishes the regulatory identity. It does not by itself establish local workflow fit, pricing, security, or performance in your environment.

FDA submission
K254001
  • FDA source
  • Exact FDA submission
  • Checked 2026-08-31
Modality
PET/SPECT/Nuclear Medicine
  • FDA source
  • Exact FDA submission
  • Checked 2026-09-03
Anatomy
Multi-region
  • FDA source
  • Exact FDA submission
  • Checked 2026-09-03
Clearance type
510(k)
  • FDA source
  • Exact FDA submission
  • Checked 2026-08-31
Decision date
2026-01-13
  • FDA source
  • Exact FDA submission
  • Checked 2026-08-31
FDA status
FDA-cleared
  • FDA source
  • Exact FDA submission
  • Checked 2026-08-31

Implementation

Questions for IT, informatics, and operations

Use these fields to structure a vendor demo, security review, and implementation estimate.

Integration
Hybrid SPECT/CT console and DICOM imaging environment; verify quantitative calibration, tracer protocols, workstation routing, and dosimetry round trips.
  • Public source
  • Exact FDA submission
  • Checked 2026-09-03
Deployment and data flow
Installed SPECT/CT system with optional console-integrated VERITAS.AI models.
  • Public source
  • Exact FDA submission
  • Checked 2026-09-03
Security and privacy
Vendor documentation pending
  • Vendor confirmation
  • Exact FDA submission
  • Checked 2026-09-03

Public materials reviewed for this batch do not establish the complete security posture for the exact release. Request data-flow, identity, audit, encryption, retention, support-access, vulnerability-management, backup, and incident-response evidence.

Training and support
Only qualified nuclear-medicine physicians, radiologists, technologists, and other trained healthcare professionals. should operate or interpret the system. Local onboarding should cover the exact release, supported population, limitations, failure examples, escalation, downtime, and competency documentation.
  • FDA source
  • Exact FDA submission
  • Checked 2026-09-03
Monitoring and change control
Monitor by exact hardware, software and model version, patient population, anatomy, protocol, operator, input quality, output edits or overrides, failed studies, repeat acquisition or rework, downstream impact, downtime, incidents, recalls, and updates. Track the limits that matter for this product: VERITAS.AI preserves the original reconstruction and is not authorized to change raw data, quantitative values, or dosimetry. Bone-IQ.AI, Thera-IQ.AI, and MIBG-IQ.AI must be used only in their labeled tracer and workflow scopes.
  • Public source
  • Exact FDA submission
  • Checked 2026-09-03

Release and scope verification

Map the installed model, build, options, population, anatomy, inputs, and outputs to K254001 before acceptance.

exact submission · checked 2026-09-03

Later product-family features are not evidence that this cleared release includes them.

Interoperability acceptance

Hybrid SPECT/CT console and DICOM imaging environment; verify quantitative calibration, tracer protocols, workstation routing, and dosimetry round trips.

exact submission · checked 2026-09-03

Test representative identifiers, orientation, geometry, measurements, units, routing, failure handling, and round trips locally.

Clinical acceptance

Use a signed local test set for the supported population and workflow. Include common and difficult cases, exclusions, acquisition variation, failed or low-quality inputs, reviewer overrides, and downstream effects. VERITAS.AI preserves the original reconstruction and is not authorized to change raw data, quantitative values, or dosimetry. Bone-IQ.AI, Thera-IQ.AI, and MIBG-IQ.AI must be used only in their labeled tracer and workflow scopes.

exact submission · checked 2026-09-03

Define stop-use, escalation, rollback, and revalidation triggers before production use.

Economic evaluation

Model capital and recurring cost against net staff time after review, throughput, repeat imaging or rework, room time, consumables, infrastructure, training, service, downtime, upgrade, and replacement costs.

product family · checked 2026-09-03

Vendor productivity claims are scenario inputs, not guaranteed local savings.

Lifecycle monitoring

Monitor by exact hardware, software and model version, patient population, anatomy, protocol, operator, input quality, output edits or overrides, failed studies, repeat acquisition or rework, downstream impact, downtime, incidents, recalls, and updates. Track the limits that matter for this product: VERITAS.AI preserves the original reconstruction and is not authorized to change raw data, quantitative values, or dosimetry. Bone-IQ.AI, Thera-IQ.AI, and MIBG-IQ.AI must be used only in their labeled tracer and workflow scopes.

exact submission · checked 2026-09-03

Revalidate after material software, hardware, model, protocol, interface, or clinical-policy changes.

Evidence

Performance evidence

Metrics are shown only when they are tied to a source, endpoint, population, and tested product version. Candidate literature without exact product and version linkage is not shown as product evidence.

Evidence summary
Exact-submission testing used a 30-patient held-out evaluation set and reported strong lesion-signal preservation with lower background variability after noise reduction. The evidence is manufacturer generated and must be supplemented with local quantitative and reader acceptance.
  • Public source
  • Exact FDA submission
  • Checked 2026-09-03
Reported sensitivity
Not applicable
  • Not applicable
  • Not applicable
  • Checked 2026-09-03

Sensitivity is not the primary applicable endpoint for this acquisition, reconstruction, segmentation, planning, guidance, or dose-delivery function. Use the task-specific endpoints and tested population reported below.

Reported specificity
Not applicable
  • Not applicable
  • Not applicable
  • Checked 2026-09-03

Specificity is not the primary applicable endpoint for this acquisition, reconstruction, segmentation, planning, guidance, or dose-delivery function. Use the task-specific endpoints and tested population reported below.

Bone lesion-signal correlation

0.99 R-squared

  • EndpointMaximum voxel intensity before versus after noise reduction
  • PopulationVERITON CT 300 Series Digital SPECT/CT System (VERITON CT 316/364); VERITON CT 400 Series Digital SPECT/CT System (VERITON CT 416/464)
  • Tested versionVERITON CT 300/400 Series with optional VERITAS.AI cleared in K254001

Bone lesion-signal slope

0.94 slope

  • EndpointMaximum voxel intensity before versus after noise reduction
  • PopulationVERITON CT 300 Series Digital SPECT/CT System (VERITON CT 316/364); VERITON CT 400 Series Digital SPECT/CT System (VERITON CT 416/464)
  • Tested versionVERITON CT 300/400 Series with optional VERITAS.AI cleared in K254001

Soft-tissue lesion-signal correlation

0.99 R-squared

  • EndpointMaximum voxel intensity before versus after noise reduction
  • PopulationVERITON CT 300 Series Digital SPECT/CT System (VERITON CT 316/364); VERITON CT 400 Series Digital SPECT/CT System (VERITON CT 416/464)
  • Tested versionVERITON CT 300/400 Series with optional VERITAS.AI cleared in K254001

Soft-tissue lesion-signal slope

0.99 slope

  • EndpointMaximum voxel intensity before versus after noise reduction
  • PopulationVERITON CT 300 Series Digital SPECT/CT System (VERITON CT 316/364); VERITON CT 400 Series Digital SPECT/CT System (VERITON CT 416/464)
  • Tested versionVERITON CT 300/400 Series with optional VERITAS.AI cleared in K254001

Bone background variability reduction

28 %

  • EndpointReduction in background SD/mean ratio
  • PopulationVERITON CT 300 Series Digital SPECT/CT System (VERITON CT 316/364); VERITON CT 400 Series Digital SPECT/CT System (VERITON CT 416/464)
  • Tested versionVERITON CT 300/400 Series with optional VERITAS.AI cleared in K254001

Soft-tissue background variability reduction

20 %

  • EndpointReduction in background SD/mean ratio
  • PopulationVERITON CT 300 Series Digital SPECT/CT System (VERITON CT 316/364); VERITON CT 400 Series Digital SPECT/CT System (VERITON CT 416/464)
  • Tested versionVERITON CT 300/400 Series with optional VERITAS.AI cleared in K254001

K254001 FDA performance package for VERITON CT 300 Series Digital SPECT/CT System (VERITON CT 316/364); VERITON CT 400 Series Digital SPECT/CT System (VERITON CT 416/464)

  • DesignManufacturer held-out clinical-image evaluation of lesion-signal preservation and background variability after VERITAS.AI noise reduction
  • Population30 patients: 13 Tc-99m bone studies and 17 soft-tissue studies, including 10 Lu-177 and 7 I-123 MIBG studies
  • Scopeexact submission
  • Tested versionVERITON CT 300/400 Series with optional VERITAS.AI cleared in K254001
  • Samplen=30
  • IndependenceSponsor or vendor study

K254001

Manufacturer evidence submitted for substantial equivalence; local clinical, technical, and workflow acceptance remains necessary.

Costs and setup

Budget and ongoing governance

These are common procurement questions; unknown values remain visible until a source supports them.

Pricing and total cost
Not established in reviewed sources
  • Reviewed sources checked
  • Exact FDA submission
  • Checked 2026-09-03

No public list price for the exact cleared configuration was found. Obtain a written quote separating hardware or license basis, enabled features, implementation, interfaces, infrastructure, training, service, upgrades, renewal, consumables, and exit costs.

Reimbursement and coding
No separate named-product Medicare payment was identified in the reviewed CMS coverage material. Evaluate the device within the applicable imaging or surgical service line and verify payer, site-of-service, and coding assumptions independently.
  • Public source
  • Not applicable
  • Checked 2026-09-03

No product-specific code

No separate named-product payment identified in reviewed public material

Centers for Medicare & Medicaid Services · United States

Build a local total-cost and value model; do not infer reimbursement from FDA clearance.

Safety and lifecycle

Postmarket record

Recall and adverse-event records are shown only after product matching. Adverse-event reports do not establish incidence or causality.

Postmarket safety review
The 2026-09-02 openFDA device-recall snapshot contained no record matched to K254001 by exact submission identifier.
  • Public source
  • Exact FDA submission
  • Checked 2026-09-03

A zero-result exact-identifier search does not prove that no recall, correction, adverse-event report, or product-family safety signal exists.

Buyer worksheet

Open questions to take to the vendor

Open evaluation checklist

Research record

What has been checked

This audit distinguishes completed source review from fields that have not yet been researched.

Human reviewedStatus
2026-09-04Last searched
26Fields reviewed
11Source classes checked
20Screened PubMed leads
10Screened trial leads
0Unreviewed FDA recall leads

Twenty PubMed records and ten trial records were screened. None identifies the VERITON CT 300/400 Series with the K254001 VERITAS.AI release. No evidence was promoted, and all 30 candidates remain quarantined. The current discovery snapshot contains 20 PubMed and 10 ClinicalTrials.gov candidate records; its dated, count-matched human screening remains current. Unlinked candidates remain quarantined. Native FDA recall identifiers produced 0 postmarket candidate records; 0 have been reviewed (0 published, 0 rejected) and 0 remain unreviewed.

Candidate leads were screened against the exact product and tested version. Unlinked records remain quarantined.

Source classes: fda ai list, fda decision summary, vendor product page, reimbursement policy, fda device recall, fda decision material, literature index, trial registry, pubmed, clinical trials, openfda device recall

Sources & history

How this profile was documented

Open the ledger for source dates, scope, and research-record updates.

View source ledger and history

Source ledger

  1. FDA 510(k) decision material K254001: VERITON CT 300 Series Digital SPECT/CT System (VERITON CT 316/364); VERITON CT 400 Series Digital SPECT/CT System (VERITON CT 416/464)

    U.S. Food and Drug Administration - Published 2026-01-13 - Accessed 2026-09-04

    Scope: identity, purpose, clinicalUse, modality, anatomy, intendedUsers, careSetting, workflowRole, input, output, limitations, evidenceSummary

  2. Artificial Intelligence-Enabled Medical Devices

    U.S. Food and Drug Administration - Accessed 2026-08-31

    Scope: regulatoryIdentity, modalityContext

  3. PubMed biomedical literature index

    U.S. National Library of Medicine - Accessed 2026-09-01

    Scope: evidenceDiscovery

  4. ClinicalTrials.gov study registry

    U.S. National Library of Medicine - Accessed 2026-09-01

    Scope: evidenceDiscovery, studyStatus

  5. Medicare Coverage Database

    Centers for Medicare & Medicaid Services - Accessed 2026-09-01

    Scope: coverage, codingContext

  6. openFDA Device Recall API

    U.S. Food and Drug Administration - Accessed 2026-09-02

    Scope: recallDiscovery, nativeSubmissionMatching

  7. VERITON Series and VERITAS.AI product-family overview

    Spectrum Dynamics Medical - Accessed 2026-09-03

    Scope: productFamily, workflowRole, implementationCapabilities, currentCommercialContext

Research history

  1. K254001 FDA decision

    Regulatory record

    510(k)

  2. Source-review record updated

    Research record

    human reviewed

  3. Reader overview source-reviewed

    Editorial review

    Source-reviewed editorial overlay

Alternatives

Related tools to compare

FDA-cleared K232712

uMI Panorama

Shanghai United Imaging Healthcare Co., Ltd.

uMI Panorama combines PET and CT to provide quantitative radiopharmaceutical distribution, diagnostic anatomical and attenuation information, and fused PET/CT images for qualified...

Modality
PET/SPECT/Nuclear Medicine
Anatomy
Multi-region
Decision
2023-10-03
FDA-cleared K231572

uMI Panorama

Shanghai United Imaging Healthcare Co., Ltd.

uMI Panorama GS combines 148 cm axial-field-of-view PET with CT to provide quantitative radiopharmaceutical distribution, diagnostic anatomical and attenuation information, and...

Modality
PET/SPECT/Nuclear Medicine
Anatomy
Multi-region
Decision
2023-07-26
FDA-cleared K223325

uMI Panorama

Shanghai United Imaging Healthcare Co., Ltd.

uMI Panorama combines PET and CT to provide quantitative radiopharmaceutical distribution, diagnostic anatomical and attenuation information, and fused PET/CT images for qualified...

Modality
PET/SPECT/Nuclear Medicine
Anatomy
Multi-region
Decision
2023-03-10
FDA-cleared K211764

Vereos PET/CT

Philips Medical Systems Nederland B.V.

Vereos PET/CT detects, localizes, diagnoses, stages, restages, and follows treatment response in oncology, cardiology, and neurology and can provide diagnostic CT and...

Modality
PET/SPECT/Nuclear Medicine
Anatomy
Multi-region
Decision
2021-08-06