Venue Fit is a general-purpose diagnostic ultrasound system for qualified and trained healthcare professionals in hospital, clinic, point-of-care, and procedural settings, with labeled abdominal, thoracic, cardiac, vascular, obstetric, pediatric, musculoskeletal, small-organ, transrectal, transvaginal, transesophageal, and interventional-guidance applications.

Evidence status: each field shows source quality, applicability, and review date. Research pending, information not established in reviewed sources, and vendor documentation pending are distinct outcomes.

Clinical fit

What this tool is for

Start with the authorized purpose, then verify how it fits your service line and reading workflow.

Exact purpose
Venue Fit is a general-purpose diagnostic ultrasound system for qualified and trained healthcare professionals in hospital, clinic, point-of-care, and procedural settings, with labeled abdominal, thoracic, cardiac, vascular, obstetric, pediatric, musculoskeletal, small-organ, transrectal, transvaginal, transesophageal, and interventional-guidance applications.
FDA source Exact FDA submission Checked 2026-09-03
Intended users
Qualified physicians, sonographers, and other trained ultrasound professionals.
FDA source Exact FDA submission Checked 2026-09-03
Care setting and population
Hospitals, clinics, offices, operating rooms, and point-of-care environments within the cleared applications.
FDA source Exact FDA submission Checked 2026-09-03
Workflow role
Ultrasound acquisition, measurement, analysis, reporting, and release-specific AI assistance.
FDA source Exact FDA submission Checked 2026-09-03
Required input
Live or imported ultrasound data from supported probes, systems, host devices, and applications.
FDA source Exact FDA submission Checked 2026-09-03
Output and human action
Ultrasound images, measurements, calculations, overlays, and reports for clinician review.
FDA source Exact FDA submission Checked 2026-09-03
Limitations
AI-assisted measurements, views, and guidance do not replace image-quality assessment or clinician interpretation; supported probes, host devices, populations, and features differ by release.
FDA source Exact FDA submission Checked 2026-09-03

Regulatory identity

FDA record and catalog context

The FDA listing establishes the regulatory identity. It does not by itself establish local workflow fit, pricing, security, or performance in your environment.

FDA submission
K220848
FDA source Exact FDA submission Checked 2026-08-31
Modality
Ultrasound
FDA source Exact FDA submission Checked 2026-09-03
Anatomy
Multi-region
FDA source Exact FDA submission Checked 2026-09-03
Clearance type
510(k)
FDA source Exact FDA submission Checked 2026-08-31
Decision date
2022-06-27
FDA source Exact FDA submission Checked 2026-08-31
FDA status
FDA-cleared
FDA source Exact FDA submission Checked 2026-08-31

Implementation

Questions for IT, informatics, and operations

Use these fields to structure a vendor demo, security review, and implementation estimate.

Integration
Validate supported probes and host devices, patient matching, DICOM or local export, PACS measurements, worklist, report transfer, and offline or downtime behavior.
Public source Product family Checked 2026-09-03

Current vendor materials are product-family evidence for K220848; confirm the exact cleared version, enabled options, deployment, and local compatibility.

Deployment and data flow
Ultrasound hardware or software with supported probes, host devices, licensed options, and network configuration.
Public source Product family Checked 2026-09-03

Current vendor materials are product-family evidence for K220848; confirm the exact cleared version, enabled options, deployment, and local compatibility.

Security and privacy
Vendor documentation pending
Vendor confirmation Exact FDA submission Checked 2026-09-03

Public materials reviewed for this exact release do not establish the complete security posture. Request data-flow, identity, audit, encryption, retention, remote-access, vulnerability-management, backup, and incident-response evidence.

Training and support
Only qualified physicians, sonographers, and other trained ultrasound professionals should operate or interpret the product. Local onboarding should cover the exact release, supported population, limitations, failure examples, escalation, downtime, and competency documentation.
FDA source Exact FDA submission Checked 2026-09-03
Monitoring and change control
Monitor by exact hardware, software, model, and algorithm version; patient population; anatomy; protocol; operator; input quality; output edits or overrides; failed studies; repeat acquisition or rework; downstream impact; downtime; incidents; recalls; and updates. Track these product-specific limits: AI-assisted measurements, views, and guidance do not replace image-quality assessment or clinician interpretation; supported probes, host devices, populations, and features differ by release.
Public source Product family Checked 2026-09-03

Current vendor materials are product-family evidence for K220848; confirm the exact cleared version, enabled options, deployment, and local compatibility.

Release and scope verification

Map the installed model, build, options, population, anatomy, inputs, outputs, and enabled AI functions to K220848 before acceptance.

exact submission · checked 2026-09-03

Later product-family features are not evidence that this cleared release includes them.

Interoperability acceptance

Validate supported probes and host devices, patient matching, DICOM or local export, PACS measurements, worklist, report transfer, and offline or downtime behavior.

product family · checked 2026-09-03

Test representative identifiers, orientation, geometry, measurements, units, routing, failure handling, and round trips locally. Vendor statements are current product-family context; confirm the exact cleared release and installed options.

Clinical acceptance

Use a signed local test set for the supported population and workflow. Include common and difficult cases, exclusions, acquisition variation, failed or low-quality inputs, reviewer overrides, and downstream effects. AI-assisted measurements, views, and guidance do not replace image-quality assessment or clinician interpretation; supported probes, host devices, populations, and features differ by release.

exact submission · checked 2026-09-03

Define stop-use, escalation, rollback, and revalidation triggers before production use.

Economic evaluation

Model capital and recurring cost against net staff time after review, throughput, repeat imaging or rework, room time, consumables, infrastructure, training, service, downtime, upgrade, and replacement costs.

product family · checked 2026-09-03

No exact-product price was found in the reviewed public material; vendor productivity claims are scenario inputs, not guaranteed local savings.

Lifecycle monitoring

Monitor by exact hardware, software, model, and algorithm version; patient population; anatomy; protocol; operator; input quality; output edits or overrides; failed studies; repeat acquisition or rework; downstream impact; downtime; incidents; recalls; and updates. Track these product-specific limits: AI-assisted measurements, views, and guidance do not replace image-quality assessment or clinician interpretation; supported probes, host devices, populations, and features differ by release.

product family · checked 2026-09-03

Revalidate after material software, hardware, model, protocol, interface, or clinical-policy changes. Vendor statements are current product-family context; confirm the exact cleared release and installed options.

Evidence

Performance evidence

Metrics are shown only when they are tied to a source, endpoint, population, and tested product version.

Evidence summary
The K220848 FDA decision summary describes Venue Fit acquisition modes, labeled examinations and procedural guidance, portability, battery and cart configurations, DICOM or QPath connectivity, and professional-use limitations. The FDA package does not establish a general AI diagnostic sensitivity or specificity claim.
FDA source Exact FDA submission Checked 2026-09-03
Reported sensitivity
Not applicable
Not applicable Not applicable Checked 2026-09-03

Sensitivity is not the primary endpoint for this system, reconstruction, segmentation, guidance, or quantitative function. Use the task-specific evidence below.

Reported specificity
Not applicable
Not applicable Not applicable Checked 2026-09-03

Specificity is not the primary endpoint for this system, reconstruction, segmentation, guidance, or quantitative function. Use the task-specific evidence below.

No contextualized exact-version metric has completed evidence review. Regulatory-document values, when available, are shown above with their limitations.

K220848 FDA performance package for Venue Fit

Manufacturer ultrasound hardware, software, acoustic, image-quality, DICOM, electrical-safety, EMC, usability, and interventional-guidance verification and validation submitted in K220848 · Adult, pediatric, fetal, cardiac, vascular, thoracic, abdominal, small-organ, and procedural ultrasound workflows using the labeled Venue Fit probes, modes, and configurations

exact submission · Tested version: Venue Fit (K220848) · Sponsor or vendor study

K220848

Manufacturer evidence submitted for FDA clearance or approval; local clinical, technical, and workflow acceptance remains necessary.

Why do People Respond Differently to Resistance Training?

ClinicalTrials.gov candidate identified by exact-name search; full product and version applicability review pending · Multi-region or related Ultrasound workflow; exact product and version linkage not established

product family · Tested version: Candidate source; exact FDA submission and product version not established · Independence not established

NCT05874986

Candidate source was found by automated exact-name search; product or version linkage and clinical endpoint were not independently established, so it must not be treated as exact-submission performance evidence.

Resistance Training, Detraining, and Retraining Study 2024 (TraDeRe2024)

ClinicalTrials.gov candidate identified by exact-name search; full product and version applicability review pending · Multi-region or related Ultrasound workflow; exact product and version linkage not established

product family · Tested version: Candidate source; exact FDA submission and product version not established · Independence not established

NCT06573086

Candidate source was found by automated exact-name search; product or version linkage and clinical endpoint were not independently established, so it must not be treated as exact-submission performance evidence.

Economics and lifecycle

Budget and ongoing governance

These are common procurement questions; unknown values remain visible until a source supports them.

Pricing and total cost
Not established in reviewed sources
Reviewed sources checked Exact FDA submission Checked 2026-09-03

No public list price for the exact cleared configuration was found. Obtain a written quote separating hardware or license basis, implementation, interfaces, infrastructure, training, service, upgrades, renewal, consumables, and exit costs.

Reimbursement and coding
No separate named-product Medicare payment was identified in the reviewed CMS coverage material. Evaluate the product within the applicable imaging, procedural, or surgical service line and verify payer, site-of-service, and coding assumptions independently.
Public source Not applicable Checked 2026-09-03

No product-specific code

No separate named-product payment identified in reviewed public material

Centers for Medicare & Medicaid Services · United States

Build a local total-cost and value model; do not infer reimbursement from FDA clearance or approval.

Safety and lifecycle

Postmarket record

Recall and adverse-event records are shown only after product matching. Adverse-event reports do not establish incidence or causality.

Postmarket safety review
1 exact-submission FDA recall record in the 2026-09-02 openFDA snapshot identify K220848. Affected model, version, unit, correction, and current manufacturer instructions still require local confirmation. FDA recall Z-1556-2025 is Open, Classified for Venue Fit Models: R3 (Model Number H45303VFSC, H45303VFSW), R4 (Model Number H45314VFS, H45314VFSW), Venue Fit R5 system (Model Numbers H45335VFS, H45335VFSW), R3 Surgery for China, R3 PeriOP for China, R3 Expert for China, R3 Pro for China, R3 Performance for China, R3 Intervention for China diagnostic ultrasound systems. FDA reason: The battery for certain ultrasound systems can potentially develop an internal failure which could result in smoke or fire. FDA action: An URGENT MEDICAL DEVICE CORRECTION notification letter dated 3/6/25 was sent to customers. Actions to be taken by Customer/User: You can continue to use your Venue Go and Venue Fit system after following the actions below: 1) Turn the system Off and unplug the system from the wall socket. 2) Remove the system batteries by following instructions provided in the User Manual Chapter 3. These instructions are also provided in this letter in Appendix A for Venue Go and in Appendix B for Venue Fit. 3) Check the date of manufacture of the system batteries by looking at the label on the bottom of each battery (See Figure 1). The date of manufacture is displayed as YYYY-MM for year and month of manufacture. NOTE: Venue Go has two batteries and Venue Fit has one battery 4) Calculate the age of each of the system batteries. 5) If any of the batteries are more than 2 years old: a. With the system unplugged, re-insert batteries, turn the system On and leave the system On to discharge the batteries. b. Once the battery capacity indicator shows two segments or less (See Figure 2), turn the system Off and remove the batteries per step 2. c. Dispose of batteries according to local regulations. NOTE: After battery removal, you can continue to use the system with use of AC power cord. The system is fully functional without the battery. 6) If the batteries are less than 2 years old, you may continue to use the battery until the battery reaches 2 years old, at which point, repeat instructions in step 5. Please ensure all potential users in your facility are made aware of this safety notification and the recommended actions. Please retain this document for your...
FDA source Exact FDA submission Checked 2026-09-04

Each published event was manually matched to the exact FDA submission and affected product or version; a recall does not establish an AI-algorithm defect or current site exposure unless the event states that scope.

recall: Z-1556-2025

Open, Classified

2025-04-11

Exact native submission match in the checked openFDA snapshot. Published as a product, system, labeling, or postmarket issue; the FDA record does not identify an AI-algorithm defect unless it says so. Confirm affected model, version, units, corrective action, and completion status locally.

Buyer worksheet

Open questions to take to the vendor

Open evaluation checklist

Research record

What has been checked

This audit distinguishes completed source review from fields that have not yet been researched.

Human reviewedStatus
2026-09-04Last searched
25Fields reviewed
11Source classes checked
0Unreviewed PubMed leads
3Unreviewed trial leads
0Unreviewed FDA recall leads

Recovered from the prior exact-submission extraction and normalized under the current provenance rules. Exact FDA decision materials were reviewed for identity, indication, users, workflow, limitations, and submitted performance. Current vendor material is labeled product-family context where it does not establish the exact release. PubMed and ClinicalTrials.gov results are retained as candidate evidence with version applicability pending; CMS reimbursement context and exact-identifier openFDA postmarket results were also checked. Pricing, final security architecture, contracted services, enabled options, and local interoperability remain organization-specific evidence. Automated exact-name discovery found 0 PubMed and 3 ClinicalTrials.gov candidate records. Candidates require human product and version matching; zero candidates is not evidence that no studies exist. 1 FDA recall candidate was manually reviewed: 1 published and 0 rejected as a neighboring or otherwise inapplicable version. Native FDA recall identifiers produced 1 postmarket candidate record; 1 has been reviewed (1 published, 0 rejected) and 0 remain unreviewed.

Candidate leads remain unpublished until a human confirms the exact product and tested version.

Source classes: fda ai list, fda decision summary, fda decision material, vendor product page, peer reviewed literature, clinical trial registry, reimbursement policy, fda device recall, pubmed, clinical trials, openfda device recall

Sources

Source ledger

Sources accessed through 2026-09-04.

Alternatives

Related tools to compare

FDA-cleared K251963

LOGIQ E10s

Ge Medical Systems Ultrasound and Primary Care Diagnostics

LOGIQ E10s is a general-purpose diagnostic ultrasound system supporting the labeled adult, pediatric, cardiac, vascular, abdominal, obstetric, small-organ, musculoskeletal,...

Modality
Ultrasound
Anatomy
Multi-region
Decision
2025-10-29
FDA-cleared K251985

LOGIQ E10

Ge Medical Systems Ultrasound and Primary Care Diagnostics

LOGIQ E10 is a general diagnostic ultrasound system for qualified users across fetal and obstetric, abdominal, gynecologic, pediatric, small-organ, breast, cardiac, vascular,...

Modality
Ultrasound
Anatomy
Multi-region
Decision
2025-10-29
FDA-cleared K250999

V8 Diagnostic Ultrasound System; cV8 Diagnostic Ultrasound System; V7 Diagnostic Ultrasound System; cV7 Diagnostic Ultrasound System; V6 Diagnostic Ultrasound System; cV6 Diagnostic Ultrasound System; V5 Diagnostic Ultrasound System; cV5 Diagnostic Ultrasound System; V4 Diagnostic Ultrasound System; cV4 Diagnostic Ultrasound System

Samsung Medison Co., Ltd.

The Samsung V-family diagnostic ultrasound systems support fetal and obstetric, abdominal, gynecologic, pediatric, small-organ, cephalic, cardiac, thoracic, vascular,...

Modality
Ultrasound
Anatomy
Multi-region
Decision
2025-07-18