FDA-cleared profile

Synapse Lung Nodule AI

Fujifilm Corporation

Authorized purpose: Concurrent-reader aid for a radiologist detecting pulmonary nodules during review of chest CT examinations in the lung cancer screening population under screening protocols.

Evidence status: each field states its source quality, applicability, and review date. Research pending, information not established, and vendor documentation pending remain distinct outcomes.

Product overview

Start with the essentials

Authorized purpose: Concurrent-reader aid for a radiologist detecting pulmonary nodules during review of chest CT examinations in the lung cancer screening population under screening protocols.

Overview status: Source-reviewed overview

Clinical takeaway

Clinical role: Concurrent-reader aid for a radiologist detecting pulmonary nodules during review of chest CT examinations in the lung cancer screening population under screening protocols.

Evidence takeaway

Evidence from the reviewed source record: The FDA packet reports a retrospective MRMC study and standalone evaluation on 300 low-dose chest CT exams from three geographically distinct US regions: 100 with at least one nodule and 200 controls; ground truth was a consensus of three board-certified thoracic radiologists and 15 readers participated. MRMC AUROC increased from 0.768 unaided to 0.835 aided (difference 0.067, p<0.001), LROC from 0.723 to 0.800 (difference 0.076, p<0.001), and reading time fell by 0.76 minutes. Standalone nodule-detection sensitivity was 78.3% (95% CI 71.0-84.8), false-positive rate was 0.76 per case (95% CI 0.64-0.90), and 3D nodule-segmentation Dice was 0.81 (95% CI 0.79-0.83).

Clinical details

What this tool is for

Start with the authorized purpose, then verify how it fits your service line and reading workflow.

Exact purpose
Concurrent-reader aid for a radiologist detecting pulmonary nodules during review of chest CT examinations in the lung cancer screening population under screening protocols.
  • FDA source
  • Exact FDA submission
  • Checked 2026-09-08
Intended users
Radiologist
  • FDA source
  • Exact FDA submission
  • Checked 2026-09-08
Care setting and population
Lung cancer screening workflow
  • FDA source
  • Exact FDA submission
  • Checked 2026-09-08
Workflow role
Concurrent-reader and post-processing detection support; results are overlaid for radiologist review
  • FDA source
  • Exact FDA submission
  • Checked 2026-09-08
Required input
Non-contrast chest CT in DICOM format, with both lungs in the field of view and slice thickness less than 3 mm; the comparison matrix lists Canon, GE, Philips, and Siemens CT systems.
  • FDA source
  • Exact FDA submission
  • Checked 2026-09-08
Output and human action
Pulmonary-nodule bounding boxes, segmented contours, and measurements including volume, long-axis length, short-axis length, average-axis length, and average Hounsfield-unit value, displayed over the original CT series in a PACS viewer.
  • FDA source
  • Exact FDA submission
  • Checked 2026-09-08
Limitations
Both lungs must be in the field of view; the device is not intended for use without the original CT series or to differentiate detected regions as benign or malignant. It is an adjunctive concurrent reader, not a substitute for the original study and radiologist interpretation.
  • FDA source
  • Exact FDA submission
  • Checked 2026-09-08

Regulatory identity

FDA record and catalog context

The FDA listing establishes the regulatory identity. It does not by itself establish local workflow fit, pricing, security, or performance in your environment.

FDA submission
K254075
  • FDA source
  • Exact FDA submission
  • Checked 2026-08-31
Modality
CT/CTA
  • FDA source
  • Exact FDA submission
  • Checked 2026-09-08
Anatomy
Chest/lungs; pulmonary nodules
  • FDA source
  • Exact FDA submission
  • Checked 2026-09-08
Clearance type
510(k)
  • FDA source
  • Exact FDA submission
  • Checked 2026-08-31
Decision date
2026-05-27
  • FDA source
  • Exact FDA submission
  • Checked 2026-08-31
FDA status
FDA-cleared
  • FDA source
  • Exact FDA submission
  • Checked 2026-08-31

Implementation

Questions for IT, informatics, and operations

Use these fields to structure a vendor demo, security review, and implementation estimate.

Integration
Retrieves DICOM images from PACS and returns nodule information to PACS, specifically Synapse PACS K190232, as an add-on with FUJIFILM hosting applications. The comparison matrix requires a PACS or DICOM-capable image viewer.
  • FDA source
  • Exact FDA submission
  • Checked 2026-09-08
Deployment and data flow
Vendor documentation pending
  • Vendor confirmation
  • Exact FDA submission
  • Checked 2026-09-08

The reviewed sources do not establish the current exact-release hosting topology, data flow, region, tenancy, or disaster-recovery configuration.

Security and privacy
Vendor documentation pending
  • Vendor confirmation
  • Exact FDA submission
  • Checked 2026-09-08

Exact-release security controls, data retention, hosting boundaries, and scoped assurance documentation require vendor confirmation.

Training and support
Vendor documentation pending
  • Vendor confirmation
  • Exact FDA submission
  • Checked 2026-09-08

Current training prerequisites, competency checks, and support commitments for the exact configuration require vendor confirmation.

Monitoring and change control
Vendor documentation pending
  • Vendor confirmation
  • Exact FDA submission
  • Checked 2026-09-08

Current drift, quality, uptime, alert, escalation, and incident-response commitments for the exact configuration require vendor confirmation.

Input or output interoperability

DICOM is explicitly referenced in the described input, output, or workflow.

exact submission · checked 2026-09-01

The model card does not establish every supported DICOM object, transfer method, or local interface.

Result destination

PACS is explicitly referenced as a result destination.

exact submission · checked 2026-09-01

Confirm supported products, versions, routing behavior, and display requirements during local evaluation.

ACR exact-submission catalog context

ACR AI Central provides an exact-submission model card for Synapse Lung Nodule AI; FDA labeling remains controlling for clinical use, limitations, and performance.

exact submission · checked 2026-09-08

Evidence

Performance evidence

Metrics are shown only when they are tied to a source, endpoint, population, and tested product version. Candidate literature without exact product and version linkage is not shown as product evidence.

Evidence summary
The FDA packet reports a retrospective MRMC study and standalone evaluation on 300 low-dose chest CT exams from three geographically distinct US regions: 100 with at least one nodule and 200 controls; ground truth was a consensus of three board-certified thoracic radiologists and 15 readers participated. MRMC AUROC increased from 0.768 unaided to 0.835 aided (difference 0.067, p<0.001), LROC from 0.723 to 0.800 (difference 0.076, p<0.001), and reading time fell by 0.76 minutes. Standalone nodule-detection sensitivity was 78.3% (95% CI 71.0-84.8), false-positive rate was 0.76 per case (95% CI 0.64-0.90), and 3D nodule-segmentation Dice was 0.81 (95% CI 0.79-0.83).
  • FDA source
  • Exact FDA submission
  • Checked 2026-09-08
Reported sensitivity
Research pending
  • Needs research
  • Exact FDA submission
  • Checked 2026-08-31

This field has not been curated yet.

Reported specificity
Research pending
  • Needs research
  • Exact FDA submission
  • Checked 2026-08-31

This field has not been curated yet.

No contextualized exact-version metric has completed evidence review. Regulatory-document values, when available, are shown above with their limitations.

Synapse Lung Nodule AI regulatory performance study summary

  • DesignReader Study
  • PopulationAdult
  • Scopeexact submission
  • Tested versionExact product version not reported; regulatory study summarized for FDA submission K254075
  • IndependenceIndependence not established

K254075

ACR AI Central summarizes the regulatory study; consult the exact FDA materials before comparative use.

Costs and setup

Budget and ongoing governance

These are common procurement questions; unknown values remain visible until a source supports them.

Pricing and total cost
Vendor documentation pending
  • Vendor confirmation
  • Exact FDA submission
  • Checked 2026-09-08

No public price or quote for the exact K254075 configuration was established in this review.

Reimbursement and coding
Not established in reviewed sources
  • Reviewed sources checked
  • Exact FDA submission
  • Checked 2026-09-08

No exact-product payer policy, coding instruction, or payment determination was established; eligibility must be evaluated by payer, site of service, and use case.

Safety and lifecycle

Postmarket record

Recall and adverse-event records are shown only after product matching. Adverse-event reports do not establish incidence or causality.

Postmarket safety review
The exact-identifier FDA recall query returned no native recall record for K254075. This limited result does not establish absence of recalls or other safety information and does not cover later versions, family records, MAUDE reports, corrections, or field notices.
  • Public source
  • Exact FDA submission
  • Checked 2026-09-08

Buyer worksheet

Open questions to take to the vendor

Open evaluation checklist

Research record

What has been checked

This audit distinguishes completed source review from fields that have not yet been researched.

Exact FDA record reviewedStatus
2026-09-20Last searched
23Fields reviewed
9Source classes checked
0Screened PubMed leads
0Screened trial leads
0Unreviewed FDA recall leads

The refreshed discovery snapshot contains no PubMed or ClinicalTrials.gov candidates; no external evidence was promoted. The current discovery snapshot contains 0 PubMed and 0 ClinicalTrials.gov candidate records; its dated, count-matched human screening remains current. Unlinked candidates remain quarantined. Native FDA recall identifiers produced 0 postmarket candidate records; 0 have been reviewed (0 published, 0 rejected) and 0 remain unreviewed.

Candidate leads were screened against the exact product and tested version. Unlinked records remain quarantined.

Source classes: fda ai list, acr ai central product, fda decision summary, fda device recall, literature index, trial registry, pubmed, clinical trials, openfda device recall

Sources & history

How this profile was documented

Open the ledger for source dates, scope, and research-record updates.

View source ledger and history

Source ledger

  1. FDA K254075: Synapse Lung Nodule AI

    U.S. Food and Drug Administration - Published 2026-05-27 - Accessed 2026-09-08

    Scope: identity, clinicalUse, modality, anatomy, workflow, evidence, implementation

  2. Artificial Intelligence-Enabled Medical Devices

    U.S. Food and Drug Administration - Accessed 2026-08-31

    Scope: regulatoryIdentity, modalityContext

  3. Synapse Lung Nodule AI model card (K254075)

    American College of Radiology - Published 2026-08-17 - Accessed 2026-09-01

    Scope: intendedUsers, careSetting, output, limitations, evidenceSummary, integration, anatomy, evidenceStudies, implementationCapabilities

  4. PubMed biomedical literature index

    U.S. National Library of Medicine - Accessed 2026-09-01

    Scope: evidenceDiscovery

  5. ClinicalTrials.gov study registry

    U.S. National Library of Medicine - Accessed 2026-09-01

    Scope: evidenceDiscovery, studyStatus

  6. openFDA Device Recall API

    U.S. Food and Drug Administration - Accessed 2026-09-02

    Scope: recallDiscovery, nativeSubmissionMatching

  7. openFDA exact recall query for K254075

    U.S. Food and Drug Administration - Accessed 2026-09-08

    Scope: postmarketSafety

Research history

  1. K254075 FDA decision

    Regulatory record

    510(k)

  2. Source-review record updated

    Research record

    fda record reviewed

  3. Reader overview source-reviewed

    Editorial review

    Source-reviewed editorial overlay

Alternatives

Related tools to compare

FDA-cleared K251769

RevealAI-Lung

Precision Medical Ventures, Inc. Dba Revealdx

Characterization and relative cancer-risk assessment of incidentally detected pulmonary nodules 6-15 mm in adults, with use as one input to follow-up and clinical decision-making...

Modality
CT/CTA
Anatomy
Pulmonary nodules in the lungs
Decision
2026-01-30