FDA-cleared profile

RayStation 2023B, RayPlan 2023B, RayStation 2024A, RayPlan 2024A, RayStation 2024A SP3, RayPlan 2024A SP3

RaySearch Laboratories AB (PUBL)

Authorized purpose: RayStation and RayPlan releases covered by K240398 are configurable radiotherapy and medical-oncology software that proposes or supports treatment plans from user inputs, with authorized users required to review and approve plans before treatment.

Evidence status: each field states its source quality, applicability, and review date. Research pending, information not established, and vendor documentation pending remain distinct outcomes.

Product overview

Start with the essentials

Authorized purpose: RayStation and RayPlan releases covered by K240398 are configurable radiotherapy and medical-oncology software that proposes or supports treatment plans from user inputs, with authorized users required to review and approve plans before treatment.

Overview status: Source-reviewed overview

Clinical takeaway

Clinical role: RayStation and RayPlan releases covered by K240398 are configurable radiotherapy and medical-oncology software that proposes or supports treatment plans from user inputs, with authorized users required to review and approve plans before treatment.

Evidence takeaway

Evidence from the reviewed source record: K240398 reports software, planning, dose, optimization, interface, and verification and validation testing for the listed releases. A plan proposal is not an autonomous treatment decision; the applicable machine, technique, image, structure, dose, and approval configuration must be checked before clinical use.

Clinical details

What this tool is for

Start with the authorized purpose, then verify how it fits your service line and reading workflow.

Exact purpose
RayStation and RayPlan releases covered by K240398 are configurable radiotherapy and medical-oncology software that proposes or supports treatment plans from user inputs, with authorized users required to review and approve plans before treatment.
  • FDA source
  • Exact FDA submission
  • Checked 2026-09-19

Exact FDA decision-summary packet reviewed on 2026-09-19; existing wording is supported without expansion.

Intended users
Authorized intended users.
  • FDA source
  • Exact FDA submission
  • Checked 2026-09-19

The exact indication identifies authorized intended users but does not name the dossier's radiation-oncology, physics, dosimetry, and therapist roles.

Care setting and population
Radiation-oncology departments using compatible planning, imaging, and treatment-delivery systems.
  • FDA source
  • Exact FDA submission
  • Checked 2026-09-03
Workflow role
Radiotherapy contouring, treatment planning, adaptation, or treatment-session management under professional review.
  • FDA source
  • Exact FDA submission
  • Checked 2026-09-03
Required input
Input to the device is patient, disease and treatment unit information.
  • FDA source
  • Exact FDA submission
  • Checked 2026-09-19

The direct packet input statement replaces the dossier's broader list of prescriptions, registrations, and treatment-session data.

Output and human action
Output from the device is one or more treatment plans. The treatment plans include treatment unit parameter settings for optimal beam arrangements, energies, field sizes, and ultimately fluence patterns to produce a safe and effective radiation dose distribution, as compared to the predicate.
  • FDA source
  • Exact FDA submission
  • Checked 2026-09-19

The exact packet supports treatment plans, treatment-unit parameters, fluence patterns, and dose distribution; it does not establish the current session-management output list.

Limitations
After a proposed treatment plan is reviewed and approved by authorized intended users, RayStation may also be used to administer treatments.
  • FDA source
  • Exact FDA submission
  • Checked 2026-09-19

This is the packet's direct review-and-approval boundary before treatment administration.

Regulatory identity

FDA record and catalog context

The FDA listing establishes the regulatory identity. It does not by itself establish local workflow fit, pricing, security, or performance in your environment.

FDA submission
K240398
  • FDA source
  • Exact FDA submission
  • Checked 2026-08-31
Modality
Radiotherapy Planning Imaging
  • FDA source
  • Exact FDA submission
  • Checked 2026-09-19

Exact FDA decision-summary packet reviewed on 2026-09-19; existing wording is supported without expansion.

Anatomy
Multi-region
  • FDA source
  • Exact FDA submission
  • Checked 2026-09-19

Exact FDA decision-summary packet reviewed on 2026-09-19; existing wording is supported without expansion.

Clearance type
510(k)
  • FDA source
  • Exact FDA submission
  • Checked 2026-08-31
Decision date
2025-04-04
  • FDA source
  • Exact FDA submission
  • Checked 2026-08-31
FDA status
FDA-cleared
  • FDA source
  • Exact FDA submission
  • Checked 2026-08-31

Implementation

Questions for IT, informatics, and operations

Use these fields to structure a vendor demo, security review, and implementation estimate.

Integration
DICOM RT and vendor workflow integration; validate patient identity, image geometry, structures, dose, plan transfer, approvals, version compatibility, and rollback.
  • Public source
  • Product family
  • Checked 2026-09-03

Current vendor materials are product-family evidence for K240398; confirm the exact cleared version, enabled options, deployment, and local compatibility.

Deployment and data flow
Licensed software connected to compatible radiotherapy planning and delivery infrastructure.
  • Public source
  • Product family
  • Checked 2026-09-03

Current vendor materials are product-family evidence for K240398; confirm the exact cleared version, enabled options, deployment, and local compatibility.

Security and privacy
Vendor documentation pending
  • Vendor confirmation
  • Exact FDA submission
  • Checked 2026-09-03

Public materials reviewed for this exact release do not establish the complete security posture. Request data-flow, identity, audit, encryption, retention, remote-access, vulnerability-management, backup, and incident-response evidence.

Training and support
Only qualified radiation oncologists, medical physicists, dosimetrists, and radiation therapists should operate or interpret the product. Local onboarding should cover the exact release, supported population, limitations, failure examples, escalation, downtime, and competency documentation.
  • FDA source
  • Exact FDA submission
  • Checked 2026-09-03
Monitoring and change control
Monitor by exact hardware, software, model, and algorithm version; patient population; anatomy; protocol; operator; input quality; output edits or overrides; failed studies; repeat acquisition or rework; downstream impact; downtime; incidents; recalls; and updates. Track these product-specific limits: Generated or modified contours and plans require qualified review, editing when needed, independent checks, and final approval before treatment.
  • Public source
  • Product family
  • Checked 2026-09-03

Current vendor materials are product-family evidence for K240398; confirm the exact cleared version, enabled options, deployment, and local compatibility.

Release and scope verification

Map the installed model, build, options, population, anatomy, inputs, outputs, and enabled AI functions to K240398 before acceptance.

exact submission · checked 2026-09-03

Later product-family features are not evidence that this cleared release includes them.

Interoperability acceptance

DICOM RT and vendor workflow integration; validate patient identity, image geometry, structures, dose, plan transfer, approvals, version compatibility, and rollback.

product family · checked 2026-09-03

Test representative identifiers, orientation, geometry, measurements, units, routing, failure handling, and round trips locally. Vendor statements are current product-family context; confirm the exact cleared release and installed options.

Clinical acceptance

Use a signed local test set for the supported population and workflow. Include common and difficult cases, exclusions, acquisition variation, failed or low-quality inputs, reviewer overrides, and downstream effects. Generated or modified contours and plans require qualified review, editing when needed, independent checks, and final approval before treatment.

exact submission · checked 2026-09-03

Define stop-use, escalation, rollback, and revalidation triggers before production use.

Economic evaluation

Model capital and recurring cost against net staff time after review, throughput, repeat imaging or rework, room time, consumables, infrastructure, training, service, downtime, upgrade, and replacement costs.

product family · checked 2026-09-03

No exact-product price was found in the reviewed public material; vendor productivity claims are scenario inputs, not guaranteed local savings.

Lifecycle monitoring

Monitor by exact hardware, software, model, and algorithm version; patient population; anatomy; protocol; operator; input quality; output edits or overrides; failed studies; repeat acquisition or rework; downstream impact; downtime; incidents; recalls; and updates. Track these product-specific limits: Generated or modified contours and plans require qualified review, editing when needed, independent checks, and final approval before treatment.

product family · checked 2026-09-03

Revalidate after material software, hardware, model, protocol, interface, or clinical-policy changes. Vendor statements are current product-family context; confirm the exact cleared release and installed options.

Evidence

Performance evidence

Metrics are shown only when they are tied to a source, endpoint, population, and tested product version. Candidate literature without exact product and version linkage is not shown as product evidence.

Evidence summary
K240398 reports software, planning, dose, optimization, interface, and verification and validation testing for the listed releases. A plan proposal is not an autonomous treatment decision; the applicable machine, technique, image, structure, dose, and approval configuration must be checked before clinical use.
  • FDA source
  • Exact FDA submission
  • Checked 2026-09-03
Reported sensitivity
Not applicable
  • Not applicable
  • Not applicable
  • Checked 2026-09-03

Sensitivity is not the primary endpoint for this system, reconstruction, segmentation, guidance, or quantitative function. Use the task-specific evidence below.

Reported specificity
Not applicable
  • Not applicable
  • Not applicable
  • Checked 2026-09-03

Specificity is not the primary endpoint for this system, reconstruction, segmentation, guidance, or quantitative function. Use the task-specific evidence below.

No contextualized exact-version metric has completed evidence review. Regulatory-document values, when available, are shown above with their limitations.

K240398 FDA performance package for RayStation 2023B, RayPlan 2023B, RayStation 2024A, RayPlan 2024A, RayStation 2024A SP3, RayPlan 2024A SP3

  • DesignManufacturer radiotherapy planning, dose, optimization, interface, and verification and validation
  • PopulationRadiotherapy planning and medical-oncology workflows using supported images, structures, prescriptions, and treatment-delivery interfaces
  • Scopeexact submission
  • Tested versionRayStation/RayPlan 2023B, 2024A, and 2024A SP3
  • IndependenceSponsor or vendor study

K240398

Manufacturer evidence submitted for FDA clearance or approval; local clinical, technical, and workflow acceptance remains necessary.

Costs and setup

Budget and ongoing governance

These are common procurement questions; unknown values remain visible until a source supports them.

Pricing and total cost
Not established in reviewed sources
  • Reviewed sources checked
  • Exact FDA submission
  • Checked 2026-09-03

No public list price for the exact cleared configuration was found. Obtain a written quote separating hardware or license basis, implementation, interfaces, infrastructure, training, service, upgrades, renewal, consumables, and exit costs.

Reimbursement and coding
No separate named-product Medicare payment was identified in the reviewed CMS radiation-oncology material. Evaluate net planning or delivery value within the radiotherapy service line.
  • Public source
  • Not applicable
  • Checked 2026-09-03

No product-specific code

No separate named-product payment identified in reviewed public material

Centers for Medicare & Medicaid Services · United States

Build a local total-cost and value model; do not infer reimbursement from FDA clearance or approval.

Safety and lifecycle

Postmarket record

Recall and adverse-event records are shown only after product matching. Adverse-event reports do not establish incidence or causality.

Postmarket safety review
2 exact-submission FDA recall records in the 2026-09-02 openFDA snapshot identify K240398. Affected model, version, unit, correction, and current manufacturer instructions still require local confirmation. FDA recall Z-1106-2026 is Open, Classified for Brand Name: RayStation Product Name: RayStation/RayPlan Model/Catalog Number: 14.0.0, 15.0.0, 15.1.3 Software Version: RayStation 2023B, RayStation 2024A, RayStation 2024A SP3 Product Description: Radiation Therapy Treatment Planning System Component: No. FDA reason: Potential for the invalidation for calculated radiation dose does not work as intended for certain Regions of Interest (ROIs). This issue occurs for some ROI(s) which have no contours and either have a material override defined, or are of type Bolus, Fixation, or Support. In these cases, adding geometry to the ROI, subsequently modifying geometry, or removing the material override does not invalidate dose as intended. FDA action: RaySearch Laboratories notified consignees via email on about 12/05/2025. Consignees were instructed to follow the outlined steps in the notification letter when adding geometry to an empty ROI with MO or type Bolus, Fixation or Support, educate planning staff and all users about the workaround, inspect units and identify all installed units with the affected software version numbers, and confirm receipt and understanding of the customer notification by responding to the notification email. The issue will be resolved in the next version of RayStation, scheduled for market release in December 2025 (subject to market clearance in some markets). If customers wish to continue using versions of RayStation affected by this notice, all users must maintain awareness of this notice. Alternatively, customers can choose to upgrade to the new version once it becomes available for clinical use. The upgrade to an unaffected software version will be scheduled in coordination with the authorized personnel, considering the specific circumstances and requirements of each individual case. The upgrade may be conducted remotely or onsite, as deemed appropriate. FDA recall Z-2495-2025 is Open, Classified for RayStation with the following product descriptions: 1. RayStation 2023B, Software Version: 14.0.0.3338. 2. RayStation 2024A, Software Version: 15.0.0.430. 3. RayStation 2024A SP3, Software Version: 15.1.3.10. Product Description: Radiation Therapy Treatment Planning System.. FDA reason: DICOM SOP Instance UID and Series Instance UID from RayGateway, i.e. the interface to Accuray's iDMS, are not guaranteed to be unique. FDA action: RaySearch notified consignees on about 08/08/2025 via email. Consignees were informed that as temporary solution, affected objects can be re-exported via RayGateway to generate new UIDs. They were instructed to inform planning staff and all users about this workaround, inspect your product and identify all installed units with the above software version number(s), and complete and return the response form. The issue will be resolved in the next version of RayStation, scheduled for market release in December 2025 (subject to market clearance in some markets). If customers wish to continue using versions of RayStation affected by this notice, all users must maintain awareness of this notice. Alternatively, customers can choose to upgrade to the new version once it becomes available for clinical use.
  • FDA source
  • Exact FDA submission
  • Checked 2026-09-04

Each published event was manually matched to the exact FDA submission and affected product or version; a recall does not establish an AI-algorithm defect or current site exposure unless the event states that scope.

recall: Z-1106-2026

Open, Classified

2026-01-16

Exact native submission match in the checked openFDA snapshot. Published as a product, system, labeling, or postmarket issue; do not infer an AI-algorithm defect unless the FDA record says so. Confirm affected model, version, units, corrective action, and completion status locally.

recall: Z-2495-2025

Open, Classified

2025-09-02

Exact native submission match in the checked openFDA snapshot. Published as a product, system, labeling, or postmarket issue; do not infer an AI-algorithm defect unless the FDA record says so. Confirm affected model, version, units, corrective action, and completion status locally.

Buyer worksheet

Open questions to take to the vendor

Open evaluation checklist

Research record

What has been checked

This audit distinguishes completed source review from fields that have not yet been researched.

Human reviewedStatus
2026-09-04Last searched
27Fields reviewed
14Source classes checked
0Screened PubMed leads
0Screened trial leads
0Unreviewed FDA recall leads

The refreshed discovery snapshot contains no PubMed or ClinicalTrials.gov candidates; no external evidence was promoted. The current discovery snapshot contains 0 PubMed and 0 ClinicalTrials.gov candidate records; its dated, count-matched human screening remains current. Unlinked candidates remain quarantined. 2 FDA recall candidates were manually reviewed: 2 published and 0 rejected as a neighboring or otherwise inapplicable version. Native FDA recall identifiers produced 2 postmarket candidate records; 2 have been reviewed (2 published, 0 rejected) and 0 remain unreviewed.

Candidate leads were screened against the exact product and tested version. Unlinked records remain quarantined.

Source classes: fda ai list, fda decision summary, fda decision material, vendor product page, peer reviewed literature, clinical trial registry, reimbursement policy, fda device recall, fda decision summary packet, literature index, trial registry, pubmed, clinical trials, openfda device recall

Sources & history

How this profile was documented

Open the ledger for source dates, scope, and research-record updates.

View source ledger and history

Source ledger

  1. FDA K240398: RayStation 2023B, RayPlan 2023B, RayStation 2024A, RayPlan 2024A, RayStation 2024A SP3, RayPlan 2024A SP3

    U.S. Food and Drug Administration - Published 2025-04-04 - Accessed 2026-09-19

    Scope: purpose, modality, anatomy, intendedUsers, input, output, limitations, evidenceSummary

  2. Artificial Intelligence-Enabled Medical Devices

    U.S. Food and Drug Administration - Accessed 2026-08-31

    Scope: regulatoryIdentity, modalityContext

  3. FDA recall Z-1106-2026: Brand Name: RayStation Product Name: RayStation/RayPlan Model/Catalog Number: 14.0.0, 15.0.0, 15.1.3 Software Version: RayStation 2023B, RayStation 2024A, RayStation 2024A SP3 Product Description: Radiation Therapy Treatment Planning System Component: No

    U.S. Food and Drug Administration - Published 2026-01-16 - Accessed 2026-09-04

    Scope: postmarketSafety, affectedProduct, recallStatus, correctiveAction

  4. FDA recall Z-2495-2025: RayStation with the following product descriptions: 1. RayStation 2023B, Software Version: 14.0.0.3338. 2. RayStation 2024A, Software Version: 15.0.0.430. 3. RayStation 2024A SP3, Software Version: 15.1.3.10. Product Description: Radiation Therapy Treatment Planning System.

    U.S. Food and Drug Administration - Published 2025-09-02 - Accessed 2026-09-04

    Scope: postmarketSafety, affectedProduct, recallStatus, correctiveAction

  5. PubMed biomedical literature index

    U.S. National Library of Medicine - Accessed 2026-09-01

    Scope: evidenceDiscovery

  6. ClinicalTrials.gov study registry

    U.S. National Library of Medicine - Accessed 2026-09-01

    Scope: evidenceDiscovery, studyStatus

  7. openFDA Device Recall API

    U.S. Food and Drug Administration - Accessed 2026-09-02

    Scope: recallDiscovery, nativeSubmissionMatching

  8. RayStation treatment planning system product page

    RaySearch Laboratories - Accessed 2026-09-02

    Scope: productFamily, implementationCapabilities, currentCommercialContext

  9. RayStation safety and performance information

    RaySearch Laboratories - Accessed 2026-09-02

    Scope: instructionsForUse, releaseNotes, systemEnvironmentGuidelines

  10. Radiation Oncology Model

    Centers for Medicare & Medicaid Services - Accessed 2026-09-02

    Scope: reimbursement, radiationTherapyPaymentContext

Research history

  1. K240398 FDA decision

    Regulatory record

    510(k)

  2. Source-review record updated

    Research record

    human reviewed

  3. Reader overview source-reviewed

    Editorial review

    Source-reviewed editorial overlay

Alternatives

Related tools to compare

FDA-cleared K242994

OncoStudio (OS-01)

OncoSoft. Co., Ltd.

OncoStudio OS-01 creates initial deep-learning organs-at-risk contours from CT images of the head and neck, thorax, abdomen, and pelvis for radiation-oncology review, editing, and...

Modality
Radiotherapy Planning Imaging
Anatomy
Multi-region
Decision
2025-02-24
FDA-cleared K232799

syngo.via RT Image Suite

Siemens Medical Solutions USA, Inc.

syngo.via RT Image Suite VB80 supports trained radiation-oncology professionals with multimodality visualization, registration, advanced contouring, treatment preparation,...

Modality
Radiotherapy Planning Imaging
Anatomy
Multi-region
Decision
2024-04-26