Authorized purpose: Support trained medical professionals in processing, visualizing, editing, and interpreting prostate MR studies, including structured PI-RADS scoring; diagnosis must not be made solely from the software analysis.
Evidence status: each field states its source quality, applicability, and review date. Research pending, information not established, and vendor documentation pending remain distinct outcomes.
Product overview
Start with the essentials
Authorized purpose: Support trained medical professionals in processing, visualizing, editing, and interpreting prostate MR studies, including structured PI-RADS scoring; diagnosis must not be made solely from the software analysis.
Overview status: Source-reviewed overview
What does this software do?Authorized purpose: Support trained medical professionals in processing, visualizing, editing, and interpreting prostate MR studies, including structured PI-RADS scoring; diagnosis must not be made solely from the software analysis.
Which images or clinical context are in scope?Modality: MRI Anatomy or clinical context: Prostate, prostatic sub-regions, and user-selected potential lesions. Input: Prostate multiparametric MRI data sets; the reviewed FDA text does not specify the complete sequence, protocol, or input-interface requirements.
Who uses it?Intended users: Trained medical professionals.
What does the software produce?Output: Registered multiparametric and biparametric combination views; prostate and sub-region segmentations; volume and PSA-density measurements; user-edited segmentations; potential-lesion segmentation and analysis; PI-RADS scoring; 3D secondary-capture segmentations; a PDF report; and DICOM output.
What is its most important limitation?Key limitation: Use is by trained medical professionals, and diagnosis must not rely solely on the analysis. Segmentations and ROI initializations are editable by the user. Prostate segmentation clinical performance was not repeated for this update; clinical testing of sub-region segmentation and ROI localization was qualitative using a five-point radiologist Likert scale. The packet does not establish sensitivity, specificity, or diagnostic AUC.
Clinical takeaway
Clinical role: Support trained medical professionals in processing, visualizing, editing, and interpreting prostate MR studies, including structured PI-RADS scoring; diagnosis must not be made solely from the software analysis.
Evidence takeaway
Evidence from the reviewed source record: FDA K230772 describes nonclinical bench testing that compared automatic prostate/sub-region segmentations with ground truth using Dice overlap and mean surface distance, with inter-observer comparisons. Clinical performance testing of sub-region segmentations and ROI localization was qualitative, using radiologist five-point Likert scores; the updated prostate-segmentation clinical test was not repeated because nonclinical performance was at least as accurate as the predicate. The updated algorithms were trained on more than 400 scans. No FDA sensitivity, specificity, diagnostic AUC, or general accuracy percentage is established.
Clinical details
What this tool is for
Start with the authorized purpose, then verify how it fits your service line and reading workflow.
Exact purpose
Support trained medical professionals in processing, visualizing, editing, and interpreting prostate MR studies, including structured PI-RADS scoring; diagnosis must not be made solely from the software analysis.
User-in-the-loop post-processing and structured interpretation aid: automatic input checks, registration, segmentation, and combination-image generation are followed by user editing, lesion analysis, PI-RADS workflow, report creation, and export.
Registered multiparametric and biparametric combination views; prostate and sub-region segmentations; volume and PSA-density measurements; user-edited segmentations; potential-lesion segmentation and analysis; PI-RADS scoring; 3D secondary-capture segmentations; a PDF report; and DICOM output.
Use is by trained medical professionals, and diagnosis must not rely solely on the analysis. Segmentations and ROI initializations are editable by the user. Prostate segmentation clinical performance was not repeated for this update; clinical testing of sub-region segmentation and ROI localization was qualitative using a five-point radiologist Likert scale. The packet does not establish sensitivity, specificity, or diagnostic AUC.
The FDA listing establishes the regulatory identity. It does not by itself establish local workflow fit, pricing, security, or performance in your environment.
Use these fields to structure a vendor demo, security review, and implementation estimate.
Integration
DICOM output, 3D secondary captures, and a PDF report are described; the packet does not establish a specific PACS, RIS, EHR, input interface, routing behavior, or interface version.
ACR AI Central provides an exact-submission model card for Quantib Prostate; FDA labeling remains controlling for clinical use, limitations, and performance.
Metrics are shown only when they are tied to a source, endpoint, population, and tested product version. Candidate literature without exact product and version linkage is not shown as product evidence.
Evidence summary
FDA K230772 describes nonclinical bench testing that compared automatic prostate/sub-region segmentations with ground truth using Dice overlap and mean surface distance, with inter-observer comparisons. Clinical performance testing of sub-region segmentations and ROI localization was qualitative, using radiologist five-point Likert scores; the updated prostate-segmentation clinical test was not repeated because nonclinical performance was at least as accurate as the predicate. The updated algorithms were trained on more than 400 scans. No FDA sensitivity, specificity, diagnostic AUC, or general accuracy percentage is established.
No contextualized exact-version metric has completed evidence review. Regulatory-document values, when available, are shown above with their limitations.
Quantib Prostate regulatory performance study summary
DesignStand-Alone Performance
PopulationPopulation described in the exact-submission ACR model card
Scopeexact submission
Tested versionExact product version not reported; regulatory study summarized for FDA submission K230772
IndependenceIndependence not established
K230772
ACR AI Central summarizes the regulatory study; consult the exact FDA materials before comparative use.
These are common procurement questions; unknown values remain visible until a source supports them.
Pricing and total cost
Vendor documentation pending
Vendor confirmation
Exact FDA submission
Checked 2026-09-09
No public price or quote for the exact K230772 configuration was established in this review.
Reimbursement and coding
Not established in reviewed sources
Reviewed sources checked
Exact FDA submission
Checked 2026-09-09
No exact-product payer policy, coding instruction, or payment determination was established; eligibility must be evaluated by payer, site of service, and use case.
Safety and lifecycle
Postmarket record
Recall and adverse-event records are shown only after product matching. Adverse-event reports do not establish incidence or causality.
Postmarket safety review
The exact-identifier FDA recall query returned no native recall record for K230772. This limited result does not establish absence of recalls or other safety information and does not cover later versions, family records, MAUDE reports, corrections, or field notices.
Verify deployment and data flow: The reviewed sources do not establish the current exact-release hosting topology, data flow, region, tenancy, or disaster-recovery configuration.
Verify security and privacy controls: Exact-release security controls, data retention, hosting boundaries, and scoped assurance documentation require vendor confirmation.
Verify training: Current training prerequisites, competency checks, and support commitments for the exact configuration require vendor confirmation.
Verify pricing and total cost: No public price or quote for the exact K230772 configuration was established in this review.
Verify reimbursement and coding relevance: No exact-product payer policy, coding instruction, or payment determination was established; eligibility must be evaluated by payer, site of service, and use case.
Verify local validation and lifecycle monitoring: Current drift, quality, uptime, alert, escalation, and incident-response commitments for the exact configuration require vendor confirmation.
This audit distinguishes completed source review from fields that have not yet been researched.
Exact FDA record reviewedStatus
2026-09-20Last searched
22Fields reviewed
9Source classes checked
4Screened PubMed leads
1Screened trial leads
0Unreviewed FDA recall leads
The refreshed discovery snapshot contains 4 PubMed and 1 ClinicalTrials.gov candidate records. Discovery metadata alone does not establish exact tested-product, version, population, and endpoint applicability, so all candidates remain quarantined and none was promoted. The current discovery snapshot contains 4 PubMed and 1 ClinicalTrials.gov candidate records; its dated, count-matched human screening remains current. Unlinked candidates remain quarantined. Native FDA recall identifiers produced 0 postmarket candidate records; 0 have been reviewed (0 published, 0 rejected) and 0 remain unreviewed.
Candidate leads were screened against the exact product and tested version. Unlinked records remain quarantined.
Source classes: fda ai list, fda decision summary, acr ai central product, fda device recall, literature index, trial registry, pubmed, clinical trials, openfda device recall
Sources & history
How this profile was documented
Open the ledger for source dates, scope, and research-record updates.
View source ledger and history7 sources - 3 history items
Concurrent-reading aid for trained physicians detecting and characterizing prostate-cancer lesions in adult males aged 40 years and older undergoing prostate MRI.
Modality
MRI
Anatomy
Prostate and lesions within or extending from the prostate
SIGNA Bolt is a whole-body MRI system for high-resolution diagnostic imaging of the labeled body regions, with supported AI-assisted reconstruction, positioning, and protocol...
SIGNA Sprint Select is a whole-body MRI system for diagnostic imaging of the labeled body regions, with supported AI-assisted reconstruction, positioning, and protocol functions.
SIGNA Sprint is a 1.5T whole-body MRI system for diagnostic imaging of the labeled head, neck, TMJ, spine, breast, heart, abdomen, pelvis, joints, prostate, vessels, and...