- Integration
- The FDA indication describes DICOM CT input, RTSTRUCT output, and a web-based interface for settings, user settings, progress, and other functions; validate DICOM RT structure transfer, patient identity, review, acceptance, and rollback locally.
The exact FDA material describes this input or interface boundary; local interoperability acceptance remains necessary.
- Deployment and data flow
- The FDA indication describes a web-based management interface but does not establish hosting, security, availability, retention, or site responsibility for the exact release.
The exact FDA material describes this release-level deployment boundary; hosting, contracts, security, availability, and site configuration remain separate evidence.
- Security and privacy
- Not established in reviewed sources
Public materials reviewed for this exact release do not establish the complete security posture. Request data-flow, identity, audit, encryption, retention, remote-access, vulnerability-management, backup, and incident-response evidence.
- Training and support
- Only qualified radiation oncologists, medical physicists, dosimetrists, radiation therapists, and trained planning staff should operate or interpret this product. Local onboarding should cover the exact release, supported population, limitations, failure examples, escalation, downtime, and competency documentation.
- Monitoring and change control
- Monitor by exact hardware, software, model, algorithm, reconstruction, or configuration version; patient population; anatomy; protocol; operator; input quality; output edits or overrides; failed studies; repeat acquisition or rework; downstream impact; downtime; incidents; recalls; and updates. Track these product-specific limits: The FDA indication limits valid input to adult-patient DICOM images, states that the software does not automatically detect or contour lesions, and requires appropriate treatment-planning or interactive-contouring software to review, edit, and accept the contours.
Release and scope verification
Map installed model, build, options, population, anatomy, inputs, outputs, and enabled functions to K231855 before acceptance. Later family features are not evidence for this exact submission.
exact submission · checked 2026-09-04 Interoperability acceptance
The FDA indication describes DICOM CT input, RTSTRUCT output, and a web-based interface for settings, user settings, progress, and other functions; validate DICOM RT structure transfer, patient identity, review, acceptance, and rollback locally. Test representative identifiers, geometry, measurements, units, routing, failure handling, and round trips locally.
exact submission · checked 2026-09-04 Deployment and security qualification
The FDA indication describes a web-based management interface but does not establish hosting, security, availability, retention, or site responsibility for the exact release. Security, availability, retention, and service responsibilities remain unverified.
exact submission · checked 2026-09-04 Clinical acceptance
Use a signed local test set for the supported population and workflow. Include common and difficult cases, exclusions, acquisition variation, failed or low-quality inputs, reviewer overrides, and downstream effects. The FDA indication limits valid input to adult-patient DICOM images, states that the software does not automatically detect or contour lesions, and requires appropriate treatment-planning or interactive-contouring software to review, edit, and accept the contours.
exact submission · checked 2026-09-04 Define stop-use, escalation, rollback, and revalidation triggers before production use.
Economic evaluation
Model capital and recurring cost against net staff time after review, throughput, repeat imaging or rework, room time, consumables, infrastructure, training, service, downtime, upgrade, and replacement costs. No exact-product price was found.
product family · checked 2026-09-04 Lifecycle monitoring
Monitor by exact hardware, software, model, algorithm, reconstruction, or configuration version; patient population; anatomy; protocol; operator; input quality; output edits or overrides; failed studies; repeat acquisition or rework; downstream impact; downtime; incidents; recalls; and updates. Track these product-specific limits: The FDA indication limits valid input to adult-patient DICOM images, states that the software does not automatically detect or contour lesions, and requires appropriate treatment-planning or interactive-contouring software to review, edit, and accept the contours.
exact submission · checked 2026-09-04 Revalidate after material software, hardware, model, protocol, interface, or clinical-policy changes.