FDA-cleared profile

OTIS 2.1 Optical Coherence Tomography System, THiA Optical Coherence Tomography System

Perimeter Medical Imaging AI, Inc.

OTIS 2.1 is indicated as an imaging tool for evaluating excised human tissue microstructure by providing two-dimensional, cross-sectional, real-time depth visualization with image-review manipulation software for identifying and annotating regions of interest.

Evidence status: each field shows source quality, applicability, and review date. Research pending, information not established in reviewed sources, and vendor documentation pending are distinct outcomes.

Clinical fit

What this tool is for

Start with the authorized purpose, then verify how it fits your service line and reading workflow.

Exact purpose
OTIS 2.1 is indicated as an imaging tool for evaluating excised human tissue microstructure by providing two-dimensional, cross-sectional, real-time depth visualization with image-review manipulation software for identifying and annotating regions of interest.
FDA source Exact FDA submission Checked 2026-09-04
Intended users
Trained physicians and procedural or pathology professionals within the labeled tissue workflow.
FDA source Exact FDA submission Checked 2026-09-04
Care setting and population
Clinical imaging or procedure settings within the labeled OCT workflow.
FDA source Exact FDA submission Checked 2026-09-04
Workflow role
OCT acquisition, real-time visualization, image manipulation, measurement, and annotation under professional control.
FDA source Exact FDA submission Checked 2026-09-04
Required input
OCT data from the supported imaging system, probe, tissue, and procedure configuration.
FDA source Exact FDA submission Checked 2026-09-04
Output and human action
Two-dimensional or volumetric cross-sectional OCT images, markers, annotations, and measurements for professional review.
FDA source Exact FDA submission Checked 2026-09-04
Limitations
The labeling is for evaluation of excised human tissue microstructure and image review or annotation; safety and effectiveness for diagnostic analysis of a specific abnormality or disease are not established by this statement.
FDA source Exact FDA submission Checked 2026-09-04

Regulatory identity

FDA record and catalog context

The FDA listing establishes the regulatory identity. It does not by itself establish local workflow fit, pricing, security, or performance in your environment.

FDA submission
K203578
FDA source Exact FDA submission Checked 2026-08-31
Modality
Optical Coherence Tomography
FDA source Exact FDA submission Checked 2026-09-04
Anatomy
Excised human tissue microstructure
FDA source Exact FDA submission Checked 2026-09-04
Clearance type
510(k)
FDA source Exact FDA submission Checked 2026-08-31
Decision date
2021-02-25
FDA source Exact FDA submission Checked 2026-08-31
FDA status
FDA-cleared
FDA source Exact FDA submission Checked 2026-08-31

Implementation

Questions for IT, informatics, and operations

Use these fields to structure a vendor demo, security review, and implementation estimate.

Integration
Standards-based DICOM/PACS integration was identified in the FDA submission materials; compatibility with a specific PACS, RIS, EHR, or orchestrator requires confirmation.
Public source Exact FDA submission Checked 2026-08-13

Normalized from the prior exact-submission review. Confirm interface versions and local compatibility during technical evaluation.

Deployment and data flow
Not established in reviewed sources
Reviewed sources checked Exact FDA submission Checked 2026-09-04

The exact public FDA decision material does not establish the complete deployment topology, hosting responsibility, availability, upgrade path, or service contract.

Security and privacy
Not established in reviewed sources
Reviewed sources checked Exact FDA submission Checked 2026-09-04

Public materials reviewed for this exact release do not establish the complete security posture. Request data-flow, identity, audit, encryption, retention, remote-access, vulnerability-management, backup, and incident-response evidence.

Training and support
Only trained physicians and procedural or pathology professionals within the labeled tissue workflow should operate or interpret the product. Local onboarding should cover the exact release, supported population, limitations, failure examples, escalation, downtime, and competency documentation.
FDA source Exact FDA submission Checked 2026-09-04
Monitoring and change control
Monitor K203578 by exact hardware, software, model, and algorithm version; patient population; anatomy; protocol; operator; input quality; output edits or overrides; failed studies; repeat acquisition or rework; downstream impact; downtime; incidents; recalls; and updates. Track these product-specific limits: The labeling is for evaluation of excised human tissue microstructure and image review or annotation; safety and effectiveness for diagnostic analysis of a specific abnormality or disease are not established by this statement.
FDA source Exact FDA submission Checked 2026-09-04

This is buyer-facing monitoring guidance derived from the exact cleared scope; it is not a claim that the FDA package provides a live monitoring service.

Release and scope verification

Map installed model, build, options, population, anatomy, inputs, outputs, and enabled functions to K203578 before acceptance.

exact submission · checked 2026-09-04

Later product-family features are not evidence that this cleared or authorized release includes them.

Deployment boundary

The exact public deployment topology remains incomplete; establish hosting responsibility, data flow, availability, upgrade, service, and downtime boundaries locally.

exact submission · checked 2026-09-04

FDA-described topology does not establish current hosting contracts, security controls, uptime, or local qualification.

Interoperability acceptance

The exact public integration contract remains incomplete; establish and test supported input, output, identity, routing, archive, and downtime behavior locally.

exact submission · checked 2026-09-04

Test representative identifiers, orientation, geometry, measurements, units, routing, failure handling, and round trips locally.

Clinical acceptance

Use a signed local test set for the supported population and workflow. Include common and difficult cases, exclusions, acquisition variation, failed or low-quality inputs, reviewer overrides, and downstream effects. The labeling is for evaluation of excised human tissue microstructure and image review or annotation; safety and effectiveness for diagnostic analysis of a specific abnormality or disease are not established by this statement.

exact submission · checked 2026-09-04

Define stop-use, escalation, rollback, and revalidation triggers before production use.

Economic evaluation

Model capital and recurring cost against net staff time after review, throughput, repeat imaging or rework, room time, consumables, infrastructure, training, service, downtime, upgrade, and replacement costs.

exact submission · checked 2026-09-04

No exact-product price or reimbursement determination was promoted.

Lifecycle monitoring

Monitor K203578 by exact hardware, software, model, and algorithm version; patient population; anatomy; protocol; operator; input quality; output edits or overrides; failed studies; repeat acquisition or rework; downstream impact; downtime; incidents; recalls; and updates. Track these product-specific limits: The labeling is for evaluation of excised human tissue microstructure and image review or annotation; safety and effectiveness for diagnostic analysis of a specific abnormality or disease are not established by this statement.

exact submission · checked 2026-09-04

Revalidate after material software, hardware, model, protocol, interface, or clinical-policy changes.

Evidence

Performance evidence

Metrics are shown only when they are tied to a source, endpoint, population, and tested product version.

Evidence summary
K203578 FDA decision material identifies the exact cleared or authorized product, intended use, labeled anatomy and modality, and submission-specific verification. It does not by itself establish product-wide sensitivity, specificity, outcomes, reimbursement, or independent clinical validation for this exact configuration.
FDA source Exact FDA submission Checked 2026-09-04
Reported sensitivity
Not applicable
Not applicable Not applicable Checked 2026-09-04

Sensitivity is not promoted as a product-wide endpoint. Compare only an exact endpoint, threshold, population, version, study design, and source if separately verified.

Reported specificity
Not applicable
Not applicable Not applicable Checked 2026-09-04

Specificity is not promoted as a product-wide endpoint. Compare only an exact endpoint, threshold, population, version, study design, and source if separately verified.

Lateral resolution

20 micrometers

OCT lateral resolution reported in the FDA comparison in Excised human tissue microstructure.

Tested version: OTIS 2.1 Optical Coherence Tomography System, THiA Optical Coherence Tomography System configuration described in K203578

Axial resolution midpoint

12.5 micrometers

Midpoint of the reported 10 to 15 micrometer axial-resolution range in Excised human tissue microstructure.

Tested version: OTIS 2.1 Optical Coherence Tomography System, THiA Optical Coherence Tomography System configuration described in K203578

K203578 FDA decision evidence package for OTIS 2.1 Optical Coherence Tomography System, THiA Optical Coherence Tomography System

FDA decision evidence including the exact submission's labeled performance or verification material; endpoints remain submission-specific. · Excised human tissue microstructure

exact submission · Tested version: OTIS 2.1 Optical Coherence Tomography System, THiA Optical Coherence Tomography System configuration described in K203578 · Sponsor or vendor study

K203578

FDA decision material is manufacturer-submitted regulatory evidence. It is not independent clinical validation unless the exact source expressly establishes that distinction; local technical, clinical, privacy, security, and workflow acceptance remains necessary.

Economics and lifecycle

Budget and ongoing governance

These are common procurement questions; unknown values remain visible until a source supports them.

Pricing and total cost
Not established in reviewed sources
Reviewed sources checked Exact FDA submission Checked 2026-09-04

No public list price for the exact cleared or authorized configuration was found. Obtain a written quote separating license or hardware basis, implementation, interfaces, infrastructure, training, service, upgrades, renewal, consumables, and exit costs.

Reimbursement and coding
Not established in reviewed sources
Reviewed sources checked Exact FDA submission Checked 2026-09-04

No exact-product reimbursement determination was promoted in this timeboxed review. Verify payer, site-of-service, coding, coverage, and local payment assumptions independently.

Safety and lifecycle

Postmarket record

Recall and adverse-event records are shown only after product matching. Adverse-event reports do not establish incidence or causality.

Postmarket safety review
The 2026-09-02 openFDA device-recall snapshot contained no record matched to K203578 by exact native submission identifier. This does not exclude product-family, later-version, or adverse-event information.
Public source Exact FDA submission Checked 2026-09-04

Exact-identifier review does not prove absence of all product-family safety signals.

Buyer worksheet

Open questions to take to the vendor

Open evaluation checklist

Research record

What has been checked

This audit distinguishes completed source review from fields that have not yet been researched.

Exact FDA record reviewedStatus
2026-09-04Last searched
26Fields reviewed
7Source classes checked
0Unreviewed PubMed leads
0Unreviewed trial leads
0Unreviewed FDA recall leads

Recovered from the prior exact-submission extraction and normalized under the current provenance rules. Scope was limited to exact FDA decision material and exact-submission recall disposition already present in the checked snapshot. Optional literature, vendor, pricing, and deployment research was not promoted. Automated exact-name discovery found 0 PubMed and 0 ClinicalTrials.gov candidate records. Candidates require human product and version matching; zero candidates is not evidence that no studies exist. Native FDA recall identifiers produced 0 postmarket candidate records; 0 have been reviewed (0 published, 0 rejected) and 0 remain unreviewed.

Candidate leads remain unpublished until a human confirms the exact product and tested version.

Source classes: fda ai list, fda decision summary, fda decision material, fda device recall, pubmed, clinical trials, openfda device recall

Sources

Source ledger

Sources accessed through 2026-09-04.

Alternatives

Related tools to compare

FDA-cleared K253459

OPTIS Mobile Next Imaging System (1014932); OPTIS Integrated Next Imaging System (1014933); Ultreon 3.0 Software Upgrade Kit (ULTR300001)

ABBOTT MEDICAL

Abbott OPTIS Mobile or Integrated Next with Ultreon 3.0 processes compatible coronary intravascular OCT data to support visualization, measurement, and interventional assessment...

Modality
Optical Coherence Tomography
Anatomy
Coronary arteries
Decision
2026-04-24
FDA-cleared K210458

OPTIS Mobile Next Imaging System, OPTIS Integrated Next Imaging System

Abbott Medical

OPTIS Mobile Next Imaging System and OPTIS Integrated Next Imaging System acquire, display, and analyze intravascular optical coherence tomography images for trained professionals...

Modality
Optical Coherence Tomography
Anatomy
Coronary arteries and intravascular anatomy
Decision
2021-06-08