FDA-cleared profile

icobrain

Icometrix

Authorized purpose: icobrain segments and quantifies brain structures and lesions from T1-weighted and FLAIR MRI using cross-sectional and longitudinal workflows with acquisition-consistency limits.

Evidence status: each field states its source quality, applicability, and review date. Research pending, information not established, and vendor documentation pending remain distinct outcomes.

Product overview

Start with the essentials

Authorized purpose: icobrain segments and quantifies brain structures and lesions from T1-weighted and FLAIR MRI using cross-sectional and longitudinal workflows with acquisition-consistency limits.

Overview status: Source-reviewed overview

Clinical takeaway

Clinical role: icobrain segments and quantifies brain structures and lesions from T1-weighted and FLAIR MRI using cross-sectional and longitudinal workflows with acquisition-consistency limits.

Evidence takeaway

Evidence from the reviewed source record: K161148 reports validation on 349 datasets with Pearson correlation 0.90 and ICC 0.89 for the evaluated measurements.

Clinical details

What this tool is for

Start with the authorized purpose, then verify how it fits your service line and reading workflow.

Exact purpose
icobrain segments and quantifies brain structures and lesions from T1-weighted and FLAIR MRI using cross-sectional and longitudinal workflows with acquisition-consistency limits.
  • FDA source
  • Exact FDA submission
  • Checked 2026-09-19

Clinical-use display mirrors the exact FDA-supported purpose reconciled from the decision-summary packet.

Intended users
icobrain is used by trained professionals in hospitals, imaging centers or in image processing labs.
  • FDA source
  • Exact FDA submission
  • Checked 2026-09-19

The exact packet gives this user and environment wording and does not establish the current list of professional roles.

Care setting and population
Hospital neuroimaging, stroke, or neurosurgical planning workflows.
  • FDA source
  • Exact FDA submission
  • Checked 2026-09-03
Workflow role
Brain-image registration, segmentation, quantification, visualization, or procedure-planning support.
  • FDA source
  • Exact FDA submission
  • Checked 2026-09-03
Required input
As input, icobrain uses T1-weighted and fluid-attenuated inversion recovery (FLAIR) DICOM MR images from a single or from multiple time points.
  • FDA source
  • Exact FDA submission
  • Checked 2026-09-19

The exact packet specifies T1-weighted and FLAIR DICOM MR images; it does not support the current CT-inclusive input value.

Output and human action
Finally, the computed volumes and volume changes (in case of multiple time points) are summarized into an electronic report and (some) segmentations are overlaid on the input images.
  • FDA source
  • Exact FDA submission
  • Checked 2026-09-19

The exact packet states electronic-report and segmentation-overlay outputs, not the current registered-image, map, alert, or planning-visualization list.

Limitations
Longitudinal analysis requires the same scanner, protocol, and contrast conditions; cross-sectional and longitudinal outputs are not interchangeable.
  • FDA source
  • Exact FDA submission
  • Checked 2026-09-19

Exact FDA decision-summary packet reviewed on 2026-09-19; existing wording is supported without expansion.

Regulatory identity

FDA record and catalog context

The FDA listing establishes the regulatory identity. It does not by itself establish local workflow fit, pricing, security, or performance in your environment.

FDA submission
K161148
  • FDA source
  • Exact FDA submission
  • Checked 2026-08-31
Modality
MRI
  • FDA source
  • Exact FDA submission
  • Checked 2026-09-19

Exact FDA decision-summary packet reviewed on 2026-09-19; existing wording is supported without expansion.

Anatomy
Brain
  • FDA source
  • Exact FDA submission
  • Checked 2026-09-19

Exact FDA decision-summary packet reviewed on 2026-09-19; existing wording is supported without expansion.

Clearance type
510(k)
  • FDA source
  • Exact FDA submission
  • Checked 2026-08-31
Decision date
2016-08-09
  • FDA source
  • Exact FDA submission
  • Checked 2026-08-31
FDA status
FDA-cleared
  • FDA source
  • Exact FDA submission
  • Checked 2026-08-31

Implementation

Questions for IT, informatics, and operations

Use these fields to structure a vendor demo, security review, and implementation estimate.

Integration
DICOM import and output to PACS, workstations, or surgical systems; validate series selection, orientation, registration, measurements, routing, latency, and failure handling.
  • Public source
  • Exact FDA submission
  • Checked 2026-09-03
Deployment and data flow
Software workstation, server, virtual appliance, or connected clinical application using the cleared release.
  • Public source
  • Exact FDA submission
  • Checked 2026-09-03
Security and privacy
Vendor documentation pending
  • Vendor confirmation
  • Exact FDA submission
  • Checked 2026-09-03

Public materials reviewed for this exact release do not establish the complete security posture. Request data-flow, identity, audit, encryption, retention, remote-access, vulnerability-management, backup, and incident-response evidence.

Training and support
Only qualified radiologists, neurologists, neurosurgeons, and trained imaging or surgical staff. should operate or interpret the product. Local onboarding should cover the exact release, supported population, limitations, failure examples, escalation, downtime, and competency documentation.
  • FDA source
  • Exact FDA submission
  • Checked 2026-09-03
Monitoring and change control
Monitor by exact hardware, software and model version, patient population, anatomy, protocol, operator, input quality, output edits or overrides, failed studies, repeat acquisition or rework, downstream impact, downtime, incidents, recalls, and updates. Track these product-specific limits: Longitudinal analysis requires the same scanner, protocol, and contrast conditions; cross-sectional and longitudinal outputs are not interchangeable.
  • Public source
  • Exact FDA submission
  • Checked 2026-09-03

Release and scope verification

Map the installed model, build, options, population, anatomy, inputs, and outputs to K161148 before acceptance.

exact submission · checked 2026-09-03

Later product-family features are not evidence that this cleared release includes them.

Interoperability acceptance

DICOM import and output to PACS, workstations, or surgical systems; validate series selection, orientation, registration, measurements, routing, latency, and failure handling.

exact submission · checked 2026-09-03

Test representative identifiers, orientation, geometry, measurements, units, routing, failure handling, and round trips locally.

Clinical acceptance

Use a signed local test set for the supported population and workflow. Include common and difficult cases, exclusions, acquisition variation, failed or low-quality inputs, reviewer overrides, and downstream effects. Longitudinal analysis requires the same scanner, protocol, and contrast conditions; cross-sectional and longitudinal outputs are not interchangeable.

exact submission · checked 2026-09-03

Define stop-use, escalation, rollback, and revalidation triggers before production use.

Economic evaluation

Model capital and recurring cost against net staff time after review, throughput, repeat imaging or rework, room time, consumables, infrastructure, training, service, downtime, upgrade, and replacement costs.

product family · checked 2026-09-03

Vendor productivity claims are scenario inputs, not guaranteed local savings.

Lifecycle monitoring

Monitor by exact hardware, software and model version, patient population, anatomy, protocol, operator, input quality, output edits or overrides, failed studies, repeat acquisition or rework, downstream impact, downtime, incidents, recalls, and updates. Track these product-specific limits: Longitudinal analysis requires the same scanner, protocol, and contrast conditions; cross-sectional and longitudinal outputs are not interchangeable.

exact submission · checked 2026-09-03

Revalidate after material software, hardware, model, protocol, interface, or clinical-policy changes.

Evidence

Performance evidence

Metrics are shown only when they are tied to a source, endpoint, population, and tested product version. Candidate literature without exact product and version linkage is not shown as product evidence.

Evidence summary
K161148 reports validation on 349 datasets with Pearson correlation 0.90 and ICC 0.89 for the evaluated measurements.
  • FDA source
  • Exact FDA submission
  • Checked 2026-09-03
Reported sensitivity
Not applicable
  • Not applicable
  • Not applicable
  • Checked 2026-09-03

Sensitivity is not the primary endpoint for this acquisition, reconstruction, segmentation, guidance, or quantitative function. Use the task-specific evidence below.

Reported specificity
Not applicable
  • Not applicable
  • Not applicable
  • Checked 2026-09-03

Specificity is not the primary endpoint for this acquisition, reconstruction, segmentation, guidance, or quantitative function. Use the task-specific evidence below.

MRI volumetry correlation

0.9 Pearson r

  • EndpointAutomated versus reference brain MRI measurements
  • Populationicobrain
  • Tested versionicobrain release cleared in K161148

MRI volumetry agreement

0.89 ICC

  • EndpointAutomated versus reference brain MRI measurements
  • Populationicobrain
  • Tested versionicobrain release cleared in K161148

K161148 FDA performance package for icobrain

  • DesignManufacturer MRI segmentation, volumetry, and agreement validation
  • Population349 brain MRI datasets using supported T1-weighted and FLAIR inputs
  • Scopeexact submission
  • Tested versionicobrain release cleared in K161148
  • Samplen=349
  • IndependenceSponsor or vendor study

K161148

Manufacturer evidence submitted for clearance or approval; local clinical, technical, and workflow acceptance remains necessary.

Costs and setup

Budget and ongoing governance

These are common procurement questions; unknown values remain visible until a source supports them.

Pricing and total cost
Not established in reviewed sources
  • Reviewed sources checked
  • Exact FDA submission
  • Checked 2026-09-03

No public list price for the exact cleared configuration was found. Obtain a written quote separating hardware or license basis, enabled features, implementation, interfaces, infrastructure, training, service, upgrades, renewal, consumables, and exit costs.

Reimbursement and coding
No separate named-product Medicare payment was identified in the reviewed CMS coverage material. Evaluate the product within the applicable imaging, procedural, or surgical service line and verify payer, site-of-service, and coding assumptions independently.
  • Public source
  • Not applicable
  • Checked 2026-09-03

No product-specific code

No separate named-product payment identified in reviewed public material

Centers for Medicare & Medicaid Services · United States

Build a local total-cost and value model; do not infer reimbursement from FDA clearance or approval.

Safety and lifecycle

Postmarket record

Recall and adverse-event records are shown only after product matching. Adverse-event reports do not establish incidence or causality.

Postmarket safety review
The 2026-09-02 openFDA device-recall snapshot contained no record matched to K161148 by exact submission identifier. This does not exclude product-family or later safety information.
  • Public source
  • Exact FDA submission
  • Checked 2026-09-03

Exact-identifier review does not prove absence of all product-family safety signals.

Buyer worksheet

Open questions to take to the vendor

Open evaluation checklist

Research record

What has been checked

This audit distinguishes completed source review from fields that have not yet been researched.

Exact FDA record reviewedStatus
2026-09-20Last searched
27Fields reviewed
13Source classes checked
20Screened PubMed leads
6Screened trial leads
0Unreviewed FDA recall leads

The refreshed discovery snapshot contains 20 PubMed and 6 ClinicalTrials.gov candidate records. Discovery metadata alone does not establish exact tested-product, version, population, and endpoint applicability, so all candidates remain quarantined and none was promoted. The current discovery snapshot contains 20 PubMed and 6 ClinicalTrials.gov candidate records; its dated, count-matched human screening remains current. Unlinked candidates remain quarantined. Native FDA recall identifiers produced 0 postmarket candidate records; 0 have been reviewed (0 published, 0 rejected) and 0 remain unreviewed.

Candidate leads were screened against the exact product and tested version. Unlinked records remain quarantined.

Source classes: fda ai list, fda decision summary, acr ai central product, fda decision material, vendor product page, reimbursement policy, fda device recall, fda decision summary packet, literature index, trial registry, pubmed, clinical trials, openfda device recall

Sources & history

How this profile was documented

Open the ledger for source dates, scope, and research-record updates.

View source ledger and history

Source ledger

  1. FDA K161148: icobrain

    U.S. Food and Drug Administration - Published 2016-08-09 - Accessed 2026-09-19

    Scope: modality, anatomy, limitations, evidenceSummary, purpose, intendedUsers, input, output, clinicalUse

  2. Artificial Intelligence-Enabled Medical Devices

    U.S. Food and Drug Administration - Accessed 2026-08-31

    Scope: regulatoryIdentity, modalityContext

  3. icobrain model card (K161148)

    American College of Radiology - Published 2026-06-26 - Accessed 2026-09-01

  4. PubMed biomedical literature index

    U.S. National Library of Medicine - Accessed 2026-09-01

    Scope: evidenceDiscovery

  5. ClinicalTrials.gov study registry

    U.S. National Library of Medicine - Accessed 2026-09-01

    Scope: evidenceDiscovery, studyStatus

  6. Medicare Coverage Database

    Centers for Medicare & Medicaid Services - Accessed 2026-09-01

    Scope: coverage, codingContext

  7. openFDA Device Recall API

    U.S. Food and Drug Administration - Accessed 2026-09-02

    Scope: recallDiscovery, nativeSubmissionMatching

  8. icobrain MRI workflow and guidelines

    icometrix - Accessed 2026-09-03

    Scope: integration, deployment, monitoring, productFamilyContext

Research history

  1. K161148 FDA decision

    Regulatory record

    510(k)

  2. Source-review record updated

    Research record

    fda record reviewed

  3. Reader overview source-reviewed

    Editorial review

    Source-reviewed editorial overlay

Alternatives

Related tools to compare

FDA-cleared K261405

ANDI 2.2

Imeka Solutions, Inc.

ANDI 2.2 processes brain MR images for atlas-assisted visualization, segmentation and volumetric quantification, presenting adjunctive DICOM-readable information for trained...

Modality
MRI
Anatomy
Brain
Decision
2026-05-28
FDA-cleared K260032

Morph

BeauBrain Healthcare, Inc.

Morph automatically labels, visualizes, and volumetrically quantifies segmentable brain structures from MR images and may compare measurements with reference percentile data; it...

Modality
MRI
Anatomy
Brain
Decision
2026-05-13
FDA-cleared K253057

AI-Rad Companion Brain MR

Siemens Healthcare GmbH

Brain MRI morphometry and white matter hyperintensity quantification, including normative comparison and longitudinal change assessment for clinician review.

Modality
MRI
Anatomy
Brain
Decision
2026-01-22
FDA-cleared K252298

ANDI 2.0

Imeka Solutions, Inc.

Adjunctive quantitative brain MRI analysis that compares patient measures with normative and longitudinal references; a physician reviews all results and makes the clinical...

Modality
MRI
Anatomy
Brain
Decision
2025-10-22