Authorized purpose: Qualitative and quantitative spine analysis from CT images to support clinician evaluation of musculoskeletal spinal disease, including vertebral labeling, vertebral height-loss measurement, and mean vertebral Hounsfield-unit measurement in patients aged 50 and over.
Evidence status: each field states its source quality, applicability, and review date. Research pending, information not established, and vendor documentation pending remain distinct outcomes.
Product overview
Start with the essentials
Authorized purpose: Qualitative and quantitative spine analysis from CT images to support clinician evaluation of musculoskeletal spinal disease, including vertebral labeling, vertebral height-loss measurement, and mean vertebral Hounsfield-unit measurement in patients aged 50 and over.
Overview status: Source-reviewed overview
What does this software do?Authorized purpose: Qualitative and quantitative spine analysis from CT images to support clinician evaluation of musculoskeletal spinal disease, including vertebral labeling, vertebral height-loss measurement, and mean vertebral Hounsfield-unit measurement in patients aged 50 and over.
Which images or clinical context are in scope?Modality: CT/CTA Anatomy or clinical context: Spine, including T1-L4 vertebrae and T11-L4 trabecular bone regions Input: DICOM CT scans of patients aged 50 and over undergoing any clinical indication, with at least four vertebrae in the T1-L4 portion for height-loss analysis and the T11-L4 portion for bone attenuation; FBP-reconstructed images only. Sagittal scans are intended, with axial scans as backup when sagittal scans are unavailable.
Who uses it?Intended users: Clinicians, including radiologists and physicians in emergency medicine, specialty care, urgent care, and general practice.
What does the software produce?Output: For each analyzed vertebra, a vertebral name, percentage height loss based on anterior/middle/posterior measurements, an indication when height loss exceeds a configurable threshold defaulting to >20%, mean trabecular-bone HU for T11-L4 with a configurable low-attenuation indication, and flags for significant height deviation from neighboring vertebrae.
What is its most important limitation?Key limitation: Use is limited to patients aged 50 and over, FBP-reconstructed CT, and the required vertebral coverage. Height-loss and bone-attenuation display thresholds are configurable from predefined lists. Axial analysis is a backup when sagittal data are unavailable, and the device is not intended as a standalone diagnostic tool.
Clinical takeaway
Clinical role: Qualitative and quantitative spine analysis from CT images to support clinician evaluation of musculoskeletal spinal disease, including vertebral labeling, vertebral height-loss measurement, and mean vertebral Hounsfield-unit measurement in patients aged 50 and over.
Evidence takeaway
Evidence from the reviewed source record: FDA stand-alone retrospective testing used 150 anonymized CT cases containing 1,425 vertebrae from two healthcare institutions with multiple US and OUS clinical sites; ground truth was determined by three US board-certified radiologists. Overall vertebral-naming agreement was 91.49% (95% CI [89.91%, 92.89%]); height-loss 95% limits of agreement were [-7.98, 7.36], with 91.86% of differences within the ground-truth readers' limits; agreement for classifying height loss above or below 20% was 91.28%; bone-attenuation 95% limits of agreement were [-20.83, 18.29], with 96.06% of differences within ground-truth readers' limits. These are agreement and limits-of-agreement endpoints, not sensitivity or specificity.
Clinical details
What this tool is for
Start with the authorized purpose, then verify how it fits your service line and reading workflow.
Exact purpose
Qualitative and quantitative spine analysis from CT images to support clinician evaluation of musculoskeletal spinal disease, including vertebral labeling, vertebral height-loss measurement, and mean vertebral Hounsfield-unit measurement in patients aged 50 and over.
Post-acquisition DICOM CT validation and analysis in parallel with standard image storage and clinician availability, with automated vertebral labeling, segmentation, height and HU measurements, configurable flags, and clinician review.
DICOM CT scans of patients aged 50 and over undergoing any clinical indication, with at least four vertebrae in the T1-L4 portion for height-loss analysis and the T11-L4 portion for bone attenuation; FBP-reconstructed images only. Sagittal scans are intended, with axial scans as backup when sagittal scans are unavailable.
For each analyzed vertebra, a vertebral name, percentage height loss based on anterior/middle/posterior measurements, an indication when height loss exceeds a configurable threshold defaulting to >20%, mean trabecular-bone HU for T11-L4 with a configurable low-attenuation indication, and flags for significant height deviation from neighboring vertebrae.
Use is limited to patients aged 50 and over, FBP-reconstructed CT, and the required vertebral coverage. Height-loss and bone-attenuation display thresholds are configurable from predefined lists. Axial analysis is a backup when sagittal data are unavailable, and the device is not intended as a standalone diagnostic tool.
The FDA listing establishes the regulatory identity. It does not by itself establish local workflow fit, pricing, security, or performance in your environment.
Use these fields to structure a vendor demo, security review, and implementation estimate.
Integration
The packet describes DICOM-compliant clinical-center infrastructure, IMA integration for study results, and error codes for validation or analysis failure; it does not establish a specific PACS, RIS, EHR, interface version, or hosting model.
Deployment category preserved from the prior exact-submission review; hosting region, data flow, and current commercial configuration still require vendor confirmation.
Metrics are shown only when they are tied to a source, endpoint, population, and tested product version. Candidate literature without exact product and version linkage is not shown as product evidence.
Evidence summary
FDA stand-alone retrospective testing used 150 anonymized CT cases containing 1,425 vertebrae from two healthcare institutions with multiple US and OUS clinical sites; ground truth was determined by three US board-certified radiologists. Overall vertebral-naming agreement was 91.49% (95% CI [89.91%, 92.89%]); height-loss 95% limits of agreement were [-7.98, 7.36], with 91.86% of differences within the ground-truth readers' limits; agreement for classifying height loss above or below 20% was 91.28%; bone-attenuation 95% limits of agreement were [-20.83, 18.29], with 96.06% of differences within ground-truth readers' limits. These are agreement and limits-of-agreement endpoints, not sensitivity or specificity.
No contextualized exact-version metric has completed evidence review. Regulatory-document values, when available, are shown above with their limitations.
HealthOST regulatory performance study summary
DesignStand-Alone Performance
PopulationAdult
Scopeexact submission
Tested versionExact product version not reported; regulatory study summarized for FDA submission K213944
Samplen=150
IndependenceIndependence not established
K213944
ACR AI Central summarizes the regulatory study; consult the exact FDA materials before comparative use.
These are common procurement questions; unknown values remain visible until a source supports them.
Pricing and total cost
Vendor documentation pending
Vendor confirmation
Exact FDA submission
Checked 2026-09-09
No public price or quote for the exact K213944 configuration was established in this review.
Reimbursement and coding
Not established in reviewed sources
Reviewed sources checked
Exact FDA submission
Checked 2026-09-09
No exact-product payer policy, coding instruction, or payment determination was established; eligibility must be evaluated by payer, site of service, and use case.
Safety and lifecycle
Postmarket record
Recall and adverse-event records are shown only after product matching. Adverse-event reports do not establish incidence or causality.
Postmarket safety review
The exact-identifier FDA recall query returned no native recall record for K213944. This limited result does not establish absence of recalls or other safety information and does not cover later versions, family records, MAUDE reports, corrections, or field notices.
Verify security and privacy controls: Exact-release security controls, data retention, hosting boundaries, and scoped assurance documentation require vendor confirmation.
Verify training: Current training prerequisites, competency checks, and support commitments for the exact configuration require vendor confirmation.
Verify pricing and total cost: No public price or quote for the exact K213944 configuration was established in this review.
Verify reimbursement and coding relevance: No exact-product payer policy, coding instruction, or payment determination was established; eligibility must be evaluated by payer, site of service, and use case.
Verify local validation and lifecycle monitoring: Current drift, quality, uptime, alert, escalation, and incident-response commitments for the exact configuration require vendor confirmation.
This audit distinguishes completed source review from fields that have not yet been researched.
Exact FDA record reviewedStatus
2026-09-20Last searched
24Fields reviewed
9Source classes checked
2Screened PubMed leads
0Screened trial leads
0Unreviewed FDA recall leads
The refreshed discovery snapshot contains 2 PubMed and 0 ClinicalTrials.gov candidate records. Discovery metadata alone does not establish exact tested-product, version, population, and endpoint applicability, so all candidates remain quarantined and none was promoted. The current discovery snapshot contains 2 PubMed and 0 ClinicalTrials.gov candidate records; its dated, count-matched human screening remains current. Unlinked candidates remain quarantined. Native FDA recall identifiers produced 0 postmarket candidate records; 0 have been reviewed (0 published, 0 rejected) and 0 remain unreviewed.
Candidate leads were screened against the exact product and tested version. Unlinked records remain quarantined.
Source classes: fda ai list, fda decision summary, acr ai central product, fda device recall, literature index, trial registry, pubmed, clinical trials, openfda device recall
Sources & history
How this profile was documented
Open the ledger for source dates, scope, and research-record updates.
View source ledger and history7 sources - 3 history items
Auto-Seg and Spine Auto-Seg accept spine and pelvis CT images and provide three-dimensional segmentation and labels to support spine-surgery planning and assessment by spine...
Acorn 3D Software and Acorn 3DP Model process CT, synthetic CT, and CT angiography for segmentation, visualization, measurement, treatment planning, and three-dimensional...
Modality
CT/CTA
Anatomy
Spine; craniomaxillofacial; musculoskeletal anatomy; and patient-specific printed models
AI-CVD provides automated quantitative CT-derived anatomical and density measurements for clinician review, including calcium scores, cardiac and vascular measurements, lung and...