Authorized purpose: Provide quantitative and qualitative liver analysis and mean attenuation measurement to support clinician evaluation and assessment of fatty liver in patients aged 18-75 whose CT includes a significant part of the liver; not for diagnosis or risk assessment of fatty liver disease.
Evidence status: each field states its source quality, applicability, and review date. Research pending, information not established, and vendor documentation pending remain distinct outcomes.
Product overview
Start with the essentials
Authorized purpose: Provide quantitative and qualitative liver analysis and mean attenuation measurement to support clinician evaluation and assessment of fatty liver in patients aged 18-75 whose CT includes a significant part of the liver; not for diagnosis or risk assessment of fatty liver disease.
Overview status: Source-reviewed overview
What does this software do?Authorized purpose: Provide quantitative and qualitative liver analysis and mean attenuation measurement to support clinician evaluation and assessment of fatty liver in patients aged 18-75 whose CT includes a significant part of the liver; not for diagnosis or risk assessment of fatty liver disease.
Which images or clinical context are in scope?Modality: CT/CTA Anatomy or clinical context: Liver Input: Non-contrast or contrast CT scans with any clinical indication for patients aged 18-75, including a significant part of the liver; the FDA technology comparison specifies DICOM and axial CT input.
Who uses it?Intended users: Clinicians.
What does the software produce?Output: Mean liver attenuation in Hounsfield Units from a region of interest, with up to three ROI annotations and threshold/reference-range indication; the display threshold is below 40 HU for non-contrast or non-portal-venous CT and below 75 HU when portal venous contrast is identified.
What is its most important limitation?Key limitation: Not intended to diagnose or provide risk assessment for fatty liver disease. The labeled age and liver-coverage requirements apply, and the validation dataset used at least 4 cm of liver from the superior aspect, which is a study inclusion criterion rather than a replacement for the labeled significant-liver-part wording. Local hosting interface and compatibility require confirmation.
Clinical takeaway
Clinical role: Provide quantitative and qualitative liver analysis and mean attenuation measurement to support clinician evaluation and assessment of fatty liver in patients aged 18-75 whose CT includes a significant part of the liver; not for diagnosis or risk assessment of fatty liver disease.
Evidence takeaway
Evidence from the reviewed source record: FDA K233080 reports a retrospective standalone validation of 250 anonymized CT scans from four healthcare institutions, with three US board-certified radiologists establishing ground truth. All 250 cases returned a result. Agreement was 95.98% for the <40 HU versus >=40 HU classification and 98.39% for <50 HU versus >=50 HU; Bland-Altman 95% limits of agreement for liver-density bias were [-7.80 HU, 7.00 HU], within the stated [-10 HU, 10 HU] interval, and portal-venous-phase identification agreement was 95.98%.
Clinical details
What this tool is for
Start with the authorized purpose, then verify how it fits your service line and reading workflow.
Exact purpose
Provide quantitative and qualitative liver analysis and mean attenuation measurement to support clinician evaluation and assessment of fatty liver in patients aged 18-75 whose CT includes a significant part of the liver; not for diagnosis or risk assessment of fatty liver disease.
DICOM intake validation followed by liver detection/segmentation, ROI attenuation quantification, result transfer to the hosting application, and error-code reporting when processing fails.
Non-contrast or contrast CT scans with any clinical indication for patients aged 18-75, including a significant part of the liver; the FDA technology comparison specifies DICOM and axial CT input.
Mean liver attenuation in Hounsfield Units from a region of interest, with up to three ROI annotations and threshold/reference-range indication; the display threshold is below 40 HU for non-contrast or non-portal-venous CT and below 75 HU when portal venous contrast is identified.
Not intended to diagnose or provide risk assessment for fatty liver disease. The labeled age and liver-coverage requirements apply, and the validation dataset used at least 4 cm of liver from the superior aspect, which is a study inclusion criterion rather than a replacement for the labeled significant-liver-part wording. Local hosting interface and compatibility require confirmation.
The FDA listing establishes the regulatory identity. It does not by itself establish local workflow fit, pricing, security, or performance in your environment.
Use these fields to structure a vendor demo, security review, and implementation estimate.
Integration
DICOM validation receives an imaging study from a hosting application and the IMA Integration feature returns successful analysis results to that application; the exact interface, version, PACS/RIS/EHR compatibility, and deployment model are not established.
Metrics are shown only when they are tied to a source, endpoint, population, and tested product version. Candidate literature without exact product and version linkage is not shown as product evidence.
Evidence summary
FDA K233080 reports a retrospective standalone validation of 250 anonymized CT scans from four healthcare institutions, with three US board-certified radiologists establishing ground truth. All 250 cases returned a result. Agreement was 95.98% for the <40 HU versus >=40 HU classification and 98.39% for <50 HU versus >=50 HU; Bland-Altman 95% limits of agreement for liver-density bias were [-7.80 HU, 7.00 HU], within the stated [-10 HU, 10 HU] interval, and portal-venous-phase identification agreement was 95.98%.
No contextualized exact-version metric has completed evidence review. Regulatory-document values, when available, are shown above with their limitations.
HealthFLD regulatory performance study summary
DesignStand-Alone Performance
PopulationAdult
Scopeexact submission
Tested versionExact product version not reported; regulatory study summarized for FDA submission K233080
Samplen=250
Sites4
IndependenceIndependence not established
K233080
ACR AI Central summarizes the regulatory study; consult the exact FDA materials before comparative use.
These are common procurement questions; unknown values remain visible until a source supports them.
Pricing and total cost
Vendor documentation pending
Vendor confirmation
Exact FDA submission
Checked 2026-09-08
No public price or quote for the exact K233080 configuration was established in this review.
Reimbursement and coding
Not established in reviewed sources
Reviewed sources checked
Exact FDA submission
Checked 2026-09-08
No exact-product payer policy, coding instruction, or payment determination was established; eligibility must be evaluated by payer, site of service, and use case.
Safety and lifecycle
Postmarket record
Recall and adverse-event records are shown only after product matching. Adverse-event reports do not establish incidence or causality.
Postmarket safety review
The exact-identifier FDA recall query returned no native recall record for K233080. This limited result does not establish absence of recalls or other safety information and does not cover later versions, family records, MAUDE reports, corrections, or field notices.
Verify deployment and data flow: The reviewed sources do not establish the current exact-release hosting topology, data flow, region, tenancy, or disaster-recovery configuration.
Verify security and privacy controls: Exact-release security controls, data retention, hosting boundaries, and scoped assurance documentation require vendor confirmation.
Verify training: Current training prerequisites, competency checks, and support commitments for the exact configuration require vendor confirmation.
Verify pricing and total cost: No public price or quote for the exact K233080 configuration was established in this review.
Verify reimbursement and coding relevance: No exact-product payer policy, coding instruction, or payment determination was established; eligibility must be evaluated by payer, site of service, and use case.
Verify local validation and lifecycle monitoring: Current drift, quality, uptime, alert, escalation, and incident-response commitments for the exact configuration require vendor confirmation.
This audit distinguishes completed source review from fields that have not yet been researched.
Exact FDA record reviewedStatus
2026-09-20Last searched
22Fields reviewed
9Source classes checked
0Screened PubMed leads
0Screened trial leads
0Unreviewed FDA recall leads
The refreshed discovery snapshot contains no PubMed or ClinicalTrials.gov candidates; no external evidence was promoted. The current discovery snapshot contains 0 PubMed and 0 ClinicalTrials.gov candidate records; its dated, count-matched human screening remains current. Unlinked candidates remain quarantined. Native FDA recall identifiers produced 0 postmarket candidate records; 0 have been reviewed (0 published, 0 rejected) and 0 remain unreviewed.
Candidate leads were screened against the exact product and tested version. Unlinked records remain quarantined.
Source classes: fda ai list, fda decision summary, acr ai central product, fda device recall, literature index, trial registry, pubmed, clinical trials, openfda device recall
Sources & history
How this profile was documented
Open the ledger for source dates, scope, and research-record updates.
View source ledger and history7 sources - 3 history items
CT and MRI image analysis, segmentation, visualization, and volumetry for adult abdominal treatment planning and follow-up, including liver surgery, living-donor, transplant, and...
Hepatic VCAR analyzes CT liver images to assess liver morphology and liver lesions with automated liver, lobe, segment, lesion, and measurement tools that a clinician can edit and...
AI-CVD provides automated quantitative CT-derived anatomical and density measurements for clinician review, including calcium scores, cardiac and vascular measurements, lung and...
uOmnispace.CT is software for viewing, manipulating, evaluating, and analyzing medical images within healthcare institutions. The FDA indication lists colon visualization, dental...
Modality
CT/CTA
Anatomy
Colon, jaw, lungs, airways, brain, heart, vessels, liver, spine, ribs, and other labeled CT regions