FDA-cleared profile

GBrain MRI

Galileo CDS, Inc

Authorized purpose: Post-processing automatic segmentation, quantification, and reporting of brain FLAIR hyperintensity volumes to support structural MRI review; not disease detection or diagnosis.

Evidence status: each field states its source quality, applicability, and review date. Research pending, information not established, and vendor documentation pending remain distinct outcomes.

Product overview

Start with the essentials

Authorized purpose: Post-processing automatic segmentation, quantification, and reporting of brain FLAIR hyperintensity volumes to support structural MRI review; not disease detection or diagnosis.

Overview status: Source-reviewed overview

Clinical takeaway

Clinical role: Post-processing automatic segmentation, quantification, and reporting of brain FLAIR hyperintensity volumes to support structural MRI review; not disease detection or diagnosis.

Evidence takeaway

Evidence from the reviewed source record: FDA packet: performance testing compared automated hyperintensity segmentations with STAPLE consensus from expert-labeled segmentations, using OLS regression and Dice similarity for volume and overlap agreement across scanner manufacturers and field strengths. The packet states that planned acceptance criteria passed but discloses no numerical performance values or case count in this submission.

Clinical details

What this tool is for

Start with the authorized purpose, then verify how it fits your service line and reading workflow.

Exact purpose
Post-processing automatic segmentation, quantification, and reporting of brain FLAIR hyperintensity volumes to support structural MRI review; not disease detection or diagnosis.
  • FDA source
  • Exact FDA submission
  • Checked 2026-09-08
Intended users
Radiologists, imaging professionals, and other clinicians working with radiological images; trained technical personnel install the software
  • FDA source
  • Exact FDA submission
  • Checked 2026-09-08
Care setting and population
Routine patient care and diagnostic radiology for adult structural brain MRI; the FDA packet does not specify a particular facility type
  • FDA source
  • Exact FDA submission
  • Checked 2026-09-08
Workflow role
Automated post-processing segmentation and volumetric reporting support with clinician review and final patient-management responsibility
  • FDA source
  • Exact FDA submission
  • Checked 2026-09-08
Required input
T2-weighted FLAIR brain MR images in DICOM format from an MRI scanner or PACS; the labeled population is adults only.
  • FDA source
  • Exact FDA submission
  • Checked 2026-09-08
Output and human action
Segmentation overlays on a new secondary-capture image series, total hyperintensity volume measurements, a DICOM Encapsulated PDF, and a DICOM Structured Report, viewable on DICOM workstations and PACS.
  • FDA source
  • Exact FDA submission
  • Checked 2026-09-08
Limitations
Contraindicated for pediatric patients and patients who have undergone brain-tumor or other resection surgery. It is not intended for detection or specific diagnosis of disease or for detection of signal hyperintensities, must not replace full MRI evaluation, and leaves final management decisions to the physician.
  • FDA source
  • Exact FDA submission
  • Checked 2026-09-08

Regulatory identity

FDA record and catalog context

The FDA listing establishes the regulatory identity. It does not by itself establish local workflow fit, pricing, security, or performance in your environment.

FDA submission
K250416
  • FDA source
  • Exact FDA submission
  • Checked 2026-08-31
Modality
MRI
  • FDA source
  • Exact FDA submission
  • Checked 2026-09-08
Anatomy
Adult brain, specifically T2-weighted FLAIR hyperintensities
  • FDA source
  • Exact FDA submission
  • Checked 2026-09-08
Clearance type
510(k)
  • FDA source
  • Exact FDA submission
  • Checked 2026-08-31
Decision date
2025-04-11
  • FDA source
  • Exact FDA submission
  • Checked 2026-08-31
FDA status
FDA-cleared
  • FDA source
  • Exact FDA submission
  • Checked 2026-08-31

Implementation

Questions for IT, informatics, and operations

Use these fields to structure a vendor demo, security review, and implementation estimate.

Integration
Packaged as a computing appliance supporting DICOM file transfer for input and output, with no user interface required after installation; processing errors are reported in the output series or system logs, and outputs are designed for third-party DICOM workstations and PACS. Installation is by trained technical personnel; exact interface versions are not established.
  • FDA source
  • Exact FDA submission
  • Checked 2026-09-08
Deployment and data flow
On-premise
  • Public source
  • Exact FDA submission
  • Checked 2026-08-13

Deployment category preserved from the prior exact-submission review; hosting region, data flow, and current commercial configuration still require vendor confirmation.

Security and privacy
Vendor documentation pending
  • Vendor confirmation
  • Exact FDA submission
  • Checked 2026-09-08

Exact-release security controls, data retention, hosting boundaries, and scoped assurance documentation require vendor confirmation.

Training and support
Vendor documentation pending
  • Vendor confirmation
  • Exact FDA submission
  • Checked 2026-09-08

Current training prerequisites, competency checks, and support commitments for the exact configuration require vendor confirmation.

Monitoring and change control
Vendor documentation pending
  • Vendor confirmation
  • Exact FDA submission
  • Checked 2026-09-08

Current drift, quality, uptime, alert, escalation, and incident-response commitments for the exact configuration require vendor confirmation.

ACR exact-submission catalog context

ACR AI Central provides an exact-submission model card for GBrain MRI; FDA labeling remains controlling for clinical use, limitations, and performance.

exact submission ยท checked 2026-09-08

Evidence

Performance evidence

Metrics are shown only when they are tied to a source, endpoint, population, and tested product version. Candidate literature without exact product and version linkage is not shown as product evidence.

Evidence summary
FDA packet: performance testing compared automated hyperintensity segmentations with STAPLE consensus from expert-labeled segmentations, using OLS regression and Dice similarity for volume and overlap agreement across scanner manufacturers and field strengths. The packet states that planned acceptance criteria passed but discloses no numerical performance values or case count in this submission.
  • FDA source
  • Exact FDA submission
  • Checked 2026-09-08
Reported sensitivity
Research pending
  • Needs research
  • Exact FDA submission
  • Checked 2026-08-31

This field has not been curated yet.

Reported specificity
Research pending
  • Needs research
  • Exact FDA submission
  • Checked 2026-08-31

This field has not been curated yet.

No contextualized exact-version metric has completed evidence review. Regulatory-document values, when available, are shown above with their limitations.

GBrain MRI regulatory performance study summary

  • DesignStand-Alone Performance
  • PopulationAdult
  • Scopeexact submission
  • Tested versionExact product version not reported; regulatory study summarized for FDA submission K250416
  • IndependenceIndependence not established

K250416

ACR AI Central summarizes the regulatory study; consult the exact FDA materials before comparative use.

Costs and setup

Budget and ongoing governance

These are common procurement questions; unknown values remain visible until a source supports them.

Pricing and total cost
Vendor documentation pending
  • Vendor confirmation
  • Exact FDA submission
  • Checked 2026-09-08

No public price or quote for the exact K250416 configuration was established in this review.

Reimbursement and coding
Not established in reviewed sources
  • Reviewed sources checked
  • Exact FDA submission
  • Checked 2026-09-08

No exact-product payer policy, coding instruction, or payment determination was established; eligibility must be evaluated by payer, site of service, and use case.

Safety and lifecycle

Postmarket record

Recall and adverse-event records are shown only after product matching. Adverse-event reports do not establish incidence or causality.

Postmarket safety review
The exact-identifier FDA recall query returned no native recall record for K250416. This limited result does not establish absence of recalls or other safety information and does not cover later versions, family records, MAUDE reports, corrections, or field notices.
  • Public source
  • Exact FDA submission
  • Checked 2026-09-08

Buyer worksheet

Open questions to take to the vendor

Open evaluation checklist

Research record

What has been checked

This audit distinguishes completed source review from fields that have not yet been researched.

Exact FDA record reviewedStatus
2026-09-20Last searched
23Fields reviewed
9Source classes checked
0Screened PubMed leads
0Screened trial leads
0Unreviewed FDA recall leads

The refreshed discovery snapshot contains no PubMed or ClinicalTrials.gov candidates; no external evidence was promoted. The current discovery snapshot contains 0 PubMed and 0 ClinicalTrials.gov candidate records; its dated, count-matched human screening remains current. Unlinked candidates remain quarantined. Native FDA recall identifiers produced 0 postmarket candidate records; 0 have been reviewed (0 published, 0 rejected) and 0 remain unreviewed.

Candidate leads were screened against the exact product and tested version. Unlinked records remain quarantined.

Source classes: fda ai list, fda decision summary, acr ai central product, fda device recall, literature index, trial registry, pubmed, clinical trials, openfda device recall

Sources & history

How this profile was documented

Open the ledger for source dates, scope, and research-record updates.

View source ledger and history

Source ledger

  1. FDA K250416: GBrain MRI

    U.S. Food and Drug Administration - Published 2025-04-11 - Accessed 2026-09-08

    Scope: identity, clinicalUse, modality, anatomy, workflow, evidence, implementation

  2. Artificial Intelligence-Enabled Medical Devices

    U.S. Food and Drug Administration - Accessed 2026-08-31

    Scope: regulatoryIdentity, modalityContext

  3. GBrain MRI model card (K250416)

    American College of Radiology - Published 2026-06-26 - Accessed 2026-09-01

    Scope: intendedUsers, careSetting, output, limitations, evidenceSummary, anatomy, evidenceStudies

  4. PubMed biomedical literature index

    U.S. National Library of Medicine - Accessed 2026-09-01

    Scope: evidenceDiscovery

  5. ClinicalTrials.gov study registry

    U.S. National Library of Medicine - Accessed 2026-09-01

    Scope: evidenceDiscovery, studyStatus

  6. openFDA Device Recall API

    U.S. Food and Drug Administration - Accessed 2026-09-02

    Scope: recallDiscovery, nativeSubmissionMatching

  7. openFDA exact recall query for K250416

    U.S. Food and Drug Administration - Accessed 2026-09-08

    Scope: postmarketSafety

Research history

  1. K250416 FDA decision

    Regulatory record

    510(k)

  2. Source-review record updated

    Research record

    fda record reviewed

  3. Reader overview source-reviewed

    Editorial review

    Source-reviewed editorial overlay

Alternatives

Related tools to compare

FDA-cleared K252362

GBrain MRI

Galileo CDS, Inc

Post-processing segmentation, quantification, and reporting of brain signal hyperintensities on T2w FLAIR and T1w post-contrast MRI; not detection or specific disease diagnosis.

Modality
MRI
Anatomy
Brain signal hyperintensities
Decision
2025-08-22
FDA-cleared K183133

MRCP+ v1.0

Perspectum Diagnostics Ltd

MRCP+v1 is indicated for use as a software-based image processing system for non-invasive, quantitative assessment of biliary system structures by facilitating the generation,...

Modality
MRI
Anatomy
Abdomen
Decision
2019-01-09
FDA-cleared K261405

ANDI 2.2

Imeka Solutions, Inc.

ANDI 2.2 processes brain MR images for atlas-assisted visualization, segmentation and volumetric quantification, presenting adjunctive DICOM-readable information for trained...

Modality
MRI
Anatomy
Brain
Decision
2026-05-28
FDA-cleared K261273

Neurophet AQUA

Neurophet., Inc.

Neurophet AQUA is intended for automatic labeling, visualization, and volumetric quantification of segmentable brain structures and lesions from a set of MR images; volumetric...

Modality
MRI
Anatomy
Brain; segmentable structures and lesions
Decision
2026-05-15