Authorized purpose: Support trained professionals in visualizing, evaluating, measuring, and reporting liver and physician-identified liver lesions on multiphase CT; it does not generate diagnoses or potential findings directly.
Evidence status: each field states its source quality, applicability, and review date. Research pending, information not established, and vendor documentation pending remain distinct outcomes.
Product overview
Start with the essentials
Authorized purpose: Support trained professionals in visualizing, evaluating, measuring, and reporting liver and physician-identified liver lesions on multiphase CT; it does not generate diagnoses or potential findings directly.
Overview status: Source-reviewed overview
What does this software do?Authorized purpose: Support trained professionals in visualizing, evaluating, measuring, and reporting liver and physician-identified liver lesions on multiphase CT; it does not generate diagnoses or potential findings directly.
Which images or clinical context are in scope?Modality: CT/CTA Anatomy or clinical context: Liver and physician-identified liver lesions. Input: Multiphase DICOM CT images with slice thickness <= 3.0 mm from patients older than 22 years; contrast-enhanced CT scans were used in the reported validation.
Who uses it?Intended users: Trained professionals including physicians and technicians; VinBrain and trained technicians carry out installation and deployment.
What does the software produce?Output: Editable liver segmentation mask; manual or physician-identified lesion segmentation; liver volume, lesion volume, maximum lesion diameter, lesion position, visualization, multiplanar reconstruction, and reporting outputs.
What is its most important limitation?Key limitation: Does not generate diagnoses or potential findings directly; qualified professionals make image interpretations and clinical decisions. The stated multiphase CT, slice-thickness <= 3.0 mm, adult, and DICOM scope applies. Installation and deployment are described as being carried out by VinBrain and trained technicians.
Clinical takeaway
Clinical role: Support trained professionals in visualizing, evaluating, measuring, and reporting liver and physician-identified liver lesions on multiphase CT; it does not generate diagnoses or potential findings directly.
Evidence takeaway
Evidence from the reviewed source record: FDA K241543 reports validation on 450 contrast-enhanced CT scans from 150 patients (age 60 +/- 12) at U.S. medical institutions, with ground truth from three U.S. board-certified radiologists. Liver segmentation had mean Dice 0.9649 (95% CI 0.9631-0.9667) and HD95 1.7061 (95% CI 1.5595-1.8526). Liver-volume measurement mean volume error was 2.7269% (95% CI 2.4308%-3.0230%). Subgroup and scanner analyses were also reported; no sensitivity or specificity disease-classification endpoint was reported.
Clinical details
What this tool is for
Start with the authorized purpose, then verify how it fits your service line and reading workflow.
Exact purpose
Support trained professionals in visualizing, evaluating, measuring, and reporting liver and physician-identified liver lesions on multiphase CT; it does not generate diagnoses or potential findings directly.
Multiphase DICOM CT images with slice thickness <= 3.0 mm from patients older than 22 years; contrast-enhanced CT scans were used in the reported validation.
Does not generate diagnoses or potential findings directly; qualified professionals make image interpretations and clinical decisions. The stated multiphase CT, slice-thickness <= 3.0 mm, adult, and DICOM scope applies. Installation and deployment are described as being carried out by VinBrain and trained technicians.
The FDA listing establishes the regulatory identity. It does not by itself establish local workflow fit, pricing, security, or performance in your environment.
Use these fields to structure a vendor demo, security review, and implementation estimate.
Integration
Web-based application running on standard hospital/clinic workstations with DICOM CT processing, viewer/manual editing, reporting, and results export. The exact PACS, RIS, EHR interface and hosting model are not established by the packet.
Deployment category preserved from the prior exact-submission review; hosting region, data flow, and current commercial configuration still require vendor confirmation.
ACR AI Central provides an exact-submission model card for DrAid™ for Liver Segmentation; FDA labeling remains controlling for clinical use, limitations, and performance.
Metrics are shown only when they are tied to a source, endpoint, population, and tested product version. Candidate literature without exact product and version linkage is not shown as product evidence.
Evidence summary
FDA K241543 reports validation on 450 contrast-enhanced CT scans from 150 patients (age 60 +/- 12) at U.S. medical institutions, with ground truth from three U.S. board-certified radiologists. Liver segmentation had mean Dice 0.9649 (95% CI 0.9631-0.9667) and HD95 1.7061 (95% CI 1.5595-1.8526). Liver-volume measurement mean volume error was 2.7269% (95% CI 2.4308%-3.0230%). Subgroup and scanner analyses were also reported; no sensitivity or specificity disease-classification endpoint was reported.
No contextualized exact-version metric has completed evidence review. Regulatory-document values, when available, are shown above with their limitations.
DrAid™ for Liver Segmentation regulatory performance study summary
DesignStand-Alone Performance
PopulationAdult
Scopeexact submission
Tested versionExact product version not reported; regulatory study summarized for FDA submission K241543
Samplen=450
IndependenceIndependence not established
K241543
ACR AI Central summarizes the regulatory study; consult the exact FDA materials before comparative use.
These are common procurement questions; unknown values remain visible until a source supports them.
Pricing and total cost
Vendor documentation pending
Vendor confirmation
Exact FDA submission
Checked 2026-09-08
No public price or quote for the exact K241543 configuration was established in this review.
Reimbursement and coding
Not established in reviewed sources
Reviewed sources checked
Exact FDA submission
Checked 2026-09-08
No exact-product payer policy, coding instruction, or payment determination was established; eligibility must be evaluated by payer, site of service, and use case.
Safety and lifecycle
Postmarket record
Recall and adverse-event records are shown only after product matching. Adverse-event reports do not establish incidence or causality.
Postmarket safety review
The exact-identifier FDA recall query returned no native recall record for K241543. This limited result does not establish absence of recalls or other safety information and does not cover later versions, family records, MAUDE reports, corrections, or field notices.
Verify security and privacy controls: Exact-release security controls, data retention, hosting boundaries, and scoped assurance documentation require vendor confirmation.
Verify training: Current training prerequisites, competency checks, and support commitments for the exact configuration require vendor confirmation.
Verify pricing and total cost: No public price or quote for the exact K241543 configuration was established in this review.
Verify reimbursement and coding relevance: No exact-product payer policy, coding instruction, or payment determination was established; eligibility must be evaluated by payer, site of service, and use case.
Verify local validation and lifecycle monitoring: Current drift, quality, uptime, alert, escalation, and incident-response commitments for the exact configuration require vendor confirmation.
This audit distinguishes completed source review from fields that have not yet been researched.
Exact FDA record reviewedStatus
2026-09-20Last searched
23Fields reviewed
9Source classes checked
0Screened PubMed leads
0Screened trial leads
0Unreviewed FDA recall leads
The refreshed discovery snapshot contains no PubMed or ClinicalTrials.gov candidates; no external evidence was promoted. The current discovery snapshot contains 0 PubMed and 0 ClinicalTrials.gov candidate records; its dated, count-matched human screening remains current. Unlinked candidates remain quarantined. Native FDA recall identifiers produced 0 postmarket candidate records; 0 have been reviewed (0 published, 0 rejected) and 0 remain unreviewed.
Candidate leads were screened against the exact product and tested version. Unlinked records remain quarantined.
Source classes: fda ai list, fda decision summary, acr ai central product, fda device recall, literature index, trial registry, pubmed, clinical trials, openfda device recall
Sources & history
How this profile was documented
Open the ledger for source dates, scope, and research-record updates.
View source ledger and history7 sources - 3 history items
AI-CVD provides automated quantitative CT-derived anatomical and density measurements for clinician review, including calcium scores, cardiac and vascular measurements, lung and...
uOmnispace.CT provides healthcare institutions with tools to view, manipulate, evaluate, and analyze medical CT images, including colon, lung, vessel, brain, cardiac, liver, rib,...
Modality
CT/CTA
Anatomy
Colon, lungs and airway, vessels, brain, heart, liver, ribs, spine, and other CT regions