Authorized purpose: Opportunistic review of frontal lumbar-spine or KUB radiographs in adults aged 50 years and older to flag possible low bone mineral density at L1-L4 for clinician follow-up; a negative result does not rule out low BMD.
Evidence status: each field states its source quality, applicability, and review date. Research pending, information not established, and vendor documentation pending remain distinct outcomes.
Product overview
Start with the essentials
Authorized purpose: Opportunistic review of frontal lumbar-spine or KUB radiographs in adults aged 50 years and older to flag possible low bone mineral density at L1-L4 for clinician follow-up; a negative result does not rule out low BMD.
Overview status: Source-reviewed overview
What does this software do?Authorized purpose: Opportunistic review of frontal lumbar-spine or KUB radiographs in adults aged 50 years and older to flag possible low bone mineral density at L1-L4 for clinician follow-up; a negative result does not rule out low BMD.
Which images or clinical context are in scope?Modality: X-ray/Radiography Anatomy or clinical context: Spine/Bone Health Input: DeepXray Spina is intended for use with standard frontal radiographs of the lumbar spine or KUB that are suitable for L1–L4 BMD analysis.
Who uses it?Intended users: Radiologists and/or physician interpreters
What does the software produce?Output: The device outputs a binary classification: 'Low BMD' (internal L1-L4 T-score 2.5) or 'Not Suspected' (internal L1-L4 T-score > 2.5). A DeepXray Spina report is generated for positive cases only, displaying a vertebral region-of-interest (ROI) overlay on the original radiograph. For negative results, no report is generated. An automated Quality-Control (QC) function detects technical and anatomical exclusion conditions and flags input images with potential quality issues.
What is its most important limitation?Key limitation: Exclusion criteria: Images in which one or more L1-L4 vertebrae contains: (a) metallic spinal implants or prostheses (e.g., pedicle screws, rods, cages, or total disc replacements); (b) vertebral cement augmentation (e.g., kyphoplasty or vertebroplasty); (c) severe vertebral deformity, fracture, or other structural abnormality that would preclude a valid DXA-based L1-L4 BMD measurement; or (d) extraspinal medical implants overlying the L1-L4 measurement region (e.g., abdominal aortic stent grafts or vascular grafts).
Clinical takeaway
Clinical role: Opportunistic review of frontal lumbar-spine or KUB radiographs in adults aged 50 years and older to flag possible low bone mineral density at L1-L4 for clinician follow-up; a negative result does not rule out low BMD.
Evidence takeaway
Evidence from the reviewed source record: Study type: Stand-Alone Performance. Cases: 1219. Reported sensitivity: 77.0% (95% CI: 72.0%, 81.9%). Reported specificity: 93.6% (95% CI: 92.1%, 95.1%)
Clinical details
What this tool is for
Start with the authorized purpose, then verify how it fits your service line and reading workflow.
Exact purpose
Opportunistic review of frontal lumbar-spine or KUB radiographs in adults aged 50 years and older to flag possible low bone mineral density at L1-L4 for clinician follow-up; a negative result does not rule out low BMD.
Confirm whether the tool is concurrent reading, triage, post-processing, planning, acquisition support, or another workflow role.
Required input
DeepXray Spina is intended for use with standard frontal radiographs of the lumbar spine or KUB that are suitable for L1–L4 BMD analysis.
FDA source
Exact FDA submission
Checked 2026-09-19
The exact input restriction states the supported frontal lumbar-spine or KUB radiographs and suitability for L1–L4 BMD analysis; the current generic consultation wording is not packet text.
The device outputs a binary classification: 'Low BMD' (internal L1-L4 T-score 2.5) or 'Not Suspected' (internal L1-L4 T-score > 2.5). A DeepXray Spina report is generated for positive cases only, displaying a vertebral region-of-interest (ROI) overlay on the original radiograph. For negative results, no report is generated. An automated Quality-Control (QC) function detects technical and anatomical exclusion conditions and flags input images with potential quality issues.
FDA source
Exact FDA submission
Checked 2026-09-19
Exact FDA decision-summary packet reviewed on 2026-09-19; existing wording is supported without expansion.
Exclusion criteria: Images in which one or more L1-L4 vertebrae contains: (a) metallic spinal implants or prostheses (e.g., pedicle screws, rods, cages, or total disc replacements); (b) vertebral cement augmentation (e.g., kyphoplasty or vertebroplasty); (c) severe vertebral deformity, fracture, or other structural abnormality that would preclude a valid DXA-based L1-L4 BMD measurement; or (d) extraspinal medical implants overlying the L1-L4 measurement region (e.g., abdominal aortic stent grafts or vascular grafts).
FDA source
Exact FDA submission
Checked 2026-09-19
Exact FDA decision-summary packet reviewed on 2026-09-19; existing wording is supported without expansion.
The FDA listing establishes the regulatory identity. It does not by itself establish local workflow fit, pricing, security, or performance in your environment.
The reviewed sources do not establish the current exact-release hosting topology, data flow, region, tenancy, or disaster-recovery configuration.
Security and privacy
Vendor documentation pending
Vendor confirmation
Exact FDA submission
Checked 2026-09-08
Exact-release security controls, data retention, hosting boundaries, and scoped assurance documentation require vendor confirmation.
Training and support
Vendor documentation pending
Vendor confirmation
Exact FDA submission
Checked 2026-09-08
Current training prerequisites, competency checks, and support commitments for the exact configuration require vendor confirmation.
Monitoring and change control
Vendor documentation pending
Vendor confirmation
Exact FDA submission
Checked 2026-09-08
Current drift, quality, uptime, alert, escalation, and incident-response commitments for the exact configuration require vendor confirmation.
ACR exact-submission catalog context
ACR AI Central provides an exact-submission model card for DeepXray Spina; FDA labeling remains controlling for clinical use, limitations, and performance.
Metrics are shown only when they are tied to a source, endpoint, population, and tested product version. Candidate literature without exact product and version linkage is not shown as product evidence.
No contextualized exact-version metric has completed evidence review. Regulatory-document values, when available, are shown above with their limitations.
DeepXray Spina regulatory performance study summary
DesignStand-Alone Performance
PopulationAdult
Scopeexact submission
Tested versionExact product version not reported; regulatory study summarized for FDA submission K253192
Samplen=1219
IndependenceIndependence not established
K253192
ACR AI Central summarizes the regulatory study; consult the exact FDA materials before comparative use.
These are common procurement questions; unknown values remain visible until a source supports them.
Pricing and total cost
Vendor documentation pending
Vendor confirmation
Exact FDA submission
Checked 2026-09-08
No public price or quote for the exact K253192 configuration was established in this review.
Reimbursement and coding
Not established in reviewed sources
Reviewed sources checked
Exact FDA submission
Checked 2026-09-08
No exact-product payer policy, coding instruction, or payment determination was established; eligibility must be evaluated by payer, site of service, and use case.
Safety and lifecycle
Postmarket record
Recall and adverse-event records are shown only after product matching. Adverse-event reports do not establish incidence or causality.
Postmarket safety review
The exact-identifier FDA recall query returned no native recall record for K253192. This limited result does not establish absence of recalls or other safety information and does not cover later versions, family records, MAUDE reports, corrections, or field notices.
Verify workflow role: Confirm whether the tool is concurrent reading, triage, post-processing, planning, acquisition support, or another workflow role.
Verify deployment and data flow: The reviewed sources do not establish the current exact-release hosting topology, data flow, region, tenancy, or disaster-recovery configuration.
Verify security and privacy controls: Exact-release security controls, data retention, hosting boundaries, and scoped assurance documentation require vendor confirmation.
Verify training: Current training prerequisites, competency checks, and support commitments for the exact configuration require vendor confirmation.
Verify pricing and total cost: No public price or quote for the exact K253192 configuration was established in this review.
Verify reimbursement and coding relevance: No exact-product payer policy, coding instruction, or payment determination was established; eligibility must be evaluated by payer, site of service, and use case.
Verify local validation and lifecycle monitoring: Current drift, quality, uptime, alert, escalation, and incident-response commitments for the exact configuration require vendor confirmation.
This audit distinguishes completed source review from fields that have not yet been researched.
Exact FDA record reviewedStatus
2026-09-20Last searched
23Fields reviewed
10Source classes checked
2Screened PubMed leads
0Screened trial leads
0Unreviewed FDA recall leads
The refreshed discovery snapshot contains 2 PubMed and 0 ClinicalTrials.gov candidate records. Discovery metadata alone does not establish exact tested-product, version, population, and endpoint applicability, so all candidates remain quarantined and none was promoted. The current discovery snapshot contains 2 PubMed and 0 ClinicalTrials.gov candidate records; its dated, count-matched human screening remains current. Unlinked candidates remain quarantined. Native FDA recall identifiers produced 0 postmarket candidate records; 0 have been reviewed (0 published, 0 rejected) and 0 remain unreviewed.
Candidate leads were screened against the exact product and tested version. Unlinked records remain quarantined.
Source classes: fda ai list, acr ai central product, fda decision summary, fda device recall, literature index, trial registry, fda decision summary packet, pubmed, clinical trials, openfda device recall
Sources & history
How this profile was documented
Open the ledger for source dates, scope, and research-record updates.
View source ledger and history7 sources - 3 history items
Rayvolve supports clinicians by identifying suspected fractures, joint effusions, and dislocations on labeled radiographic views; it does not replace clinician interpretation.
Modality
X-ray/Radiography
Anatomy
Musculoskeletal and chest/ribs radiographs across specified views
Concurrent-read CADe to assist dentists in detecting specified tooth and jaw anatomy, bone-level landmarks, and root-canal-treated teeth in digital radiographs of permanent teeth...
Modality
X-ray/Radiography
Anatomy
Permanent teeth and jaw/maxillofacial anatomy, including enamel, dentine, pulp, root, mental foramen, inferior alveolar canal, maxillary sinus, cementoenamel junction, crestal bone, and root-canal-treated teeth
qXR-Detect is an adult chest-radiograph concurrent reading aid that identifies, highlights and categorizes suspicious regions of interest across lung, pleura,...
Modality
X-ray/Radiography
Anatomy
Chest/Lung; pleura, mediastinum/hila/heart, bone, hardware and other chest-radiograph regions