System and version relationships
Match the AI release, system build, configuration and region. Source documentation does not establish acceptance of an installed system.
No specific system/version pairing has completed review for this FDA record. A broad DICOM or product-family statement does not establish a named viewer build's support.
Review Merge, Visage, Sectra, AGFA and IntelePACS context
Release and scope verification
Map installed model, build, options, population, anatomy, inputs, outputs, and enabled functions to K193073 before acceptance.
exact submission · checked 2026-09-04 Later product-family features are not evidence that this cleared or authorized release includes them.
Deployment boundary
The exact public deployment topology remains incomplete; establish hosting responsibility, data flow, availability, upgrade, service, and downtime boundaries locally.
exact submission · checked 2026-09-04 FDA-described topology does not establish current hosting contracts, security controls, uptime, or local qualification.
Interoperability acceptance
The exact public integration contract remains incomplete; establish and test supported input, output, identity, routing, archive, and downtime behavior locally.
exact submission · checked 2026-09-04 Test representative identifiers, orientation, geometry, measurements, units, routing, failure handling, and round trips locally.
Clinical acceptance
Use a signed local test set for the supported population and workflow. Include common and difficult cases, exclusions, acquisition variation, failed or low-quality inputs, reviewer overrides, and downstream effects. The exact indication is limited to adult head, chest, abdomen, cardiac, and vascular CT applications on uCT 760 or uCT 780 systems; do not generalize to other scanners or populations.
exact submission · checked 2026-09-04 Define stop-use, escalation, rollback, and revalidation triggers before production use.
Economic evaluation
Model capital and recurring cost against net staff time after review, throughput, repeat imaging or rework, room time, consumables, infrastructure, training, service, downtime, upgrade, and replacement costs.
exact submission · checked 2026-09-04 No exact-product price or reimbursement determination was promoted.
Lifecycle monitoring
Monitor K193073 by exact hardware, software, model, and algorithm version; patient population; anatomy; protocol; operator; input quality; output edits or overrides; failed studies; repeat acquisition or rework; downstream impact; downtime; incidents; recalls; and updates. Track these product-specific limits: The exact indication is limited to adult head, chest, abdomen, cardiac, and vascular CT applications on uCT 760 or uCT 780 systems; do not generalize to other scanners or populations.
exact submission · checked 2026-09-04 Revalidate after material software, hardware, model, protocol, interface, or clinical-policy changes.