FDA-cleared profile

Cydar EV (Series B) and Cydar EV Maps

Cydar Ltd.

Cydar EV and Cydar EV Maps support the labeled endovascular workflow by processing and displaying patient-specific vascular imaging and maps for trained procedural professionals under direct clinical control.

Evidence status: each field shows source quality, applicability, and review date. Research pending, information not established in reviewed sources, and vendor documentation pending are distinct outcomes.

Clinical fit

What this tool is for

Start with the authorized purpose, then verify how it fits your service line and reading workflow.

Exact purpose
Cydar EV and Cydar EV Maps support the labeled endovascular workflow by processing and displaying patient-specific vascular imaging and maps for trained procedural professionals under direct clinical control.
FDA source Exact FDA submission Checked 2026-09-04
Intended users
Qualified interventional physicians, surgeons, radiologists, technologists, and other trained procedural staff.
FDA source Exact FDA submission Checked 2026-09-04
Care setting and population
Hospital interventional, cardiovascular, operating-room, or procedure-suite workflows within the cleared indication.
FDA source Exact FDA submission Checked 2026-09-04
Workflow role
Image registration, fusion, localization, or procedural guidance under direct professional control.
FDA source Exact FDA submission Checked 2026-09-04
Required input
Supported live X-ray, vascular, or other labeled images and procedure-specific user inputs.
FDA source Exact FDA submission Checked 2026-09-04
Output and human action
Registered images, landmarks, overlays, measurements, or navigation guidance for professional review.
FDA source Exact FDA submission Checked 2026-09-04
Limitations
The operator remains responsible for source-image review, target confirmation, calibration, and fallback when inputs, registration, tracking, or output quality are inadequate.
FDA source Exact FDA submission Checked 2026-09-04

Regulatory identity

FDA record and catalog context

The FDA listing establishes the regulatory identity. It does not by itself establish local workflow fit, pricing, security, or performance in your environment.

FDA submission
K212442
FDA source Exact FDA submission Checked 2026-08-31
Modality
Fluoroscopy/Angiography
FDA source Exact FDA submission Checked 2026-09-04
Anatomy
Peripheral vascular and endovascular anatomy
FDA source Exact FDA submission Checked 2026-09-04
Clearance type
510(k)
FDA source Exact FDA submission Checked 2026-08-31
Decision date
2021-12-03
FDA source Exact FDA submission Checked 2026-08-31
FDA status
FDA-cleared
FDA source Exact FDA submission Checked 2026-08-31

Implementation

Questions for IT, informatics, and operations

Use these fields to structure a vendor demo, security review, and implementation estimate.

Integration
Standards-based DICOM/PACS integration was identified in the FDA submission materials; compatibility with a specific PACS, RIS, EHR, or orchestrator requires confirmation.
Public source Exact FDA submission Checked 2026-08-13

Normalized from the prior exact-submission review. Confirm interface versions and local compatibility during technical evaluation.

Deployment and data flow
On-cloud
Public source Exact FDA submission Checked 2026-08-13

Deployment category preserved from the prior exact-submission review; hosting region, data flow, and current commercial configuration still require vendor confirmation.

Security and privacy
Not established in reviewed sources
Reviewed sources checked Exact FDA submission Checked 2026-09-04

Public materials reviewed for this exact release do not establish the complete security posture. Request data-flow, identity, audit, encryption, retention, remote-access, vulnerability-management, backup, and incident-response evidence.

Training and support
Only qualified interventional physicians, surgeons, radiologists, technologists, and other trained procedural staff should operate or interpret the product. Local onboarding should cover the exact release, supported population, limitations, failure examples, escalation, downtime, and competency documentation.
FDA source Exact FDA submission Checked 2026-09-04
Monitoring and change control
Monitor K212442 by exact hardware, software, model, and algorithm version; patient population; anatomy; protocol; operator; input quality; output edits or overrides; failed studies; repeat acquisition or rework; downstream impact; downtime; incidents; recalls; and updates. Track these product-specific limits: The operator remains responsible for source-image review, target confirmation, calibration, and fallback when inputs, registration, tracking, or output quality are inadequate.
FDA source Exact FDA submission Checked 2026-09-04

Monitoring guidance is buyer-facing implementation guidance derived from the exact cleared scope; it is not a claim that the FDA package provides a live monitoring service.

Release and scope verification

Map installed model, build, options, population, anatomy, inputs, outputs, and enabled functions to K212442 before acceptance.

exact submission · checked 2026-09-04

Later product-family features are not evidence that this cleared release includes them.

Deployment boundary

The exact public deployment topology remains incomplete; establish hosting responsibility, data flow, availability, upgrade, service, and downtime boundaries locally.

exact submission · checked 2026-09-04

FDA-described deployment boundaries do not establish current hosting contracts, security controls, uptime, or local qualification.

Interoperability acceptance

The exact public integration contract remains incomplete; establish and test supported input, output, identity, routing, archive, and downtime behavior locally.

exact submission · checked 2026-09-04

Test representative identifiers, orientation, geometry, measurements, units, routing, failure handling, and round trips locally.

Clinical acceptance

Use a signed local test set for the supported population and workflow. Include common and difficult cases, exclusions, acquisition variation, failed or low-quality inputs, reviewer overrides, and downstream effects. The operator remains responsible for source-image review, target confirmation, calibration, and fallback when inputs, registration, tracking, or output quality are inadequate.

exact submission · checked 2026-09-04

Define stop-use, escalation, rollback, and revalidation triggers before production use.

Economic evaluation

Model capital and recurring cost against net staff time after review, throughput, repeat imaging or rework, room time, consumables, infrastructure, training, service, downtime, upgrade, and replacement costs.

product family · checked 2026-09-04

No exact-product price was found in the reviewed public material; productivity or value claims require local evidence.

Lifecycle monitoring

Monitor K212442 by exact hardware, software, model, and algorithm version; patient population; anatomy; protocol; operator; input quality; output edits or overrides; failed studies; repeat acquisition or rework; downstream impact; downtime; incidents; recalls; and updates. Track these product-specific limits: The operator remains responsible for source-image review, target confirmation, calibration, and fallback when inputs, registration, tracking, or output quality are inadequate.

exact submission · checked 2026-09-04

Revalidate after material software, hardware, model, protocol, interface, or clinical-policy changes. image-guidance and procedural visualization software limits remain submission-specific.

Evidence

Performance evidence

Metrics are shown only when they are tied to a source, endpoint, population, and tested product version.

Evidence summary
K212442 FDA decision material describes the cleared image-guidance and procedural visualization software, labeled use, and submission-specific verification. It does not establish product-wide sensitivity, specificity, outcomes, or independent clinical validation for this exact configuration.
FDA source Exact FDA submission Checked 2026-09-04
Reported sensitivity
Not applicable
Not applicable Not applicable Checked 2026-09-04

Sensitivity is not promoted as a product-wide endpoint for this device or software function. Compare only an exact endpoint, threshold, population, version, and source if later verified.

Reported specificity
Not applicable
Not applicable Not applicable Checked 2026-09-04

Specificity is not promoted as a product-wide endpoint for this device or software function. Compare only an exact endpoint, threshold, population, version, and source if later verified.

No contextualized exact-version metric has completed evidence review. Regulatory-document values, when available, are shown above with their limitations.

K212442 FDA evidence package for Cydar EV (Series B) and Cydar EV Maps

FDA 510(k) substantial-equivalence decision evidence and product verification described in the exact submission. · Peripheral vascular and endovascular anatomy

exact submission · Tested version: Cydar EV (Series B) and Cydar EV Maps configuration described in K212442 · Sponsor or vendor study

K212442

Manufacturer evidence submitted for the exact FDA decision. It is not independent clinical validation, and local technical, clinical, privacy, security, and workflow acceptance remains necessary.

Economics and lifecycle

Budget and ongoing governance

These are common procurement questions; unknown values remain visible until a source supports them.

Pricing and total cost
Not established in reviewed sources
Reviewed sources checked Exact FDA submission Checked 2026-09-04

No public list price for the exact cleared configuration was found. Obtain a written quote separating hardware or license basis, implementation, interfaces, infrastructure, training, service, upgrades, renewal, consumables, and exit costs.

Reimbursement and coding
No separate named-product Medicare payment was identified in the reviewed CMS coverage material. Evaluate the product within the applicable imaging, procedural, or surgical service line and verify payer, site-of-service, and coding assumptions independently.
Public source Not applicable Checked 2026-09-04

No product-specific code

No separate named-product payment identified in reviewed public material

Centers for Medicare & Medicaid Services · United States

This is not a product-specific reimbursement determination. Build a local total-cost and value model and verify payer, site-of-service, coding, and coverage assumptions independently.

Safety and lifecycle

Postmarket record

Recall and adverse-event records are shown only after product matching. Adverse-event reports do not establish incidence or causality.

Postmarket safety review
The 2026-09-02 openFDA device-recall snapshot contained no record matched to K212442 by exact native submission identifier. This does not exclude product-family, later, or adverse-event information.
Public source Exact FDA submission Checked 2026-09-04

Exact-identifier review does not prove absence of all product-family safety signals.

Buyer worksheet

Open questions to take to the vendor

Open evaluation checklist

Research record

What has been checked

This audit distinguishes completed source review from fields that have not yet been researched.

Human reviewedStatus
2026-09-04Last searched
26Fields reviewed
10Source classes checked
0Unreviewed PubMed leads
0Unreviewed trial leads
0Unreviewed FDA recall leads

Recovered from the prior exact-submission extraction and normalized under the current provenance rules. Exact-name and exact-submission searches in the checked 2026-09-01 indexes returned no PubMed records and no ClinicalTrials.gov records for K212442; review status is candidate_review_pending. Literature and registry candidates remain quarantined unless exact submission and tested-version linkage is established. The checked recall disposition is no exact-submission recall record was promoted; ambiguous or family-only candidates are not published. Pricing, complete security architecture, contracted deployment, exact reimbursement, and local interoperability remain unverified. Automated exact-name discovery found 0 PubMed and 0 ClinicalTrials.gov candidate records. Candidates require human product and version matching; zero candidates is not evidence that no studies exist. Native FDA recall identifiers produced 0 postmarket candidate records; 0 have been reviewed (0 published, 0 rejected) and 0 remain unreviewed.

Candidate leads remain unpublished until a human confirms the exact product and tested version.

Source classes: fda ai list, fda decision summary, fda decision material, peer reviewed literature, clinical trial registry, reimbursement policy, fda device recall, pubmed, clinical trials, openfda device recall

Sources

Source ledger

Sources accessed through 2026-09-04.

Alternatives

Related tools to compare

FDA-cleared K260077

OrthoGrid Hip AI® 4.0

OrthoGrid Systems, Inc.

OrthoGrid Hip AI 4.0 analyzes two-dimensional C-arm fluoroscopic images to assist positioning of hip-replacement components during direct-anterior total hip arthroplasty.

Modality
Fluoroscopy/Angiography
Anatomy
Hip
Decision
2026-05-29
FDA-cleared K252503

Intelligent NR

Canon, Inc.

Canon Intelligent NR is a noise-reduction function for fluoroscopic images acquired on compatible Canon radiography and fluoroscopy systems.

Modality
Fluoroscopy/Angiography
Anatomy
Whole body; diagnostic and interventional anatomy
Decision
2026-04-30
FDA-cleared K253269

OEC One CFD

Ge Hualun Medical Systems Co., Ltd.

OEC One CFD provides fluoroscopic and digital-spot images for adult and pediatric diagnostic, interventional, surgical, orthopedic, gastrointestinal, urologic, neurologic,...

Modality
Fluoroscopy/Angiography
Anatomy
Orthopedic, gastrointestinal, endoscopic, urologic, neurologic, vascular, critical-care, and emergency anatomy
Decision
2025-11-26
FDA-cleared K243446

3DXR

GE Medical Systems SCS

3DXR reconstructs cone-beam CT from interventional X-ray acquisitions and uses CleaRecon DL to reduce streak artifacts for display in the advanced workstation workflow.

Modality
Fluoroscopy/Angiography
Anatomy
Multi-region
Decision
2025-02-25