Authorized purpose: Web-based post-processing of cardiac CT data from CCTA performed for CAD or suspected CAD to view and analyze coronary plaques/atherosclerosis and stenosis and support measurement and visualization of coronary arteries.
Evidence status: each field states its source quality, applicability, and review date. Research pending, information not established, and vendor documentation pending remain distinct outcomes.
Product overview
Start with the essentials
Authorized purpose: Web-based post-processing of cardiac CT data from CCTA performed for CAD or suspected CAD to view and analyze coronary plaques/atherosclerosis and stenosis and support measurement and visualization of coronary arteries.
Overview status: Source-reviewed overview
What does this software do?Authorized purpose: Web-based post-processing of cardiac CT data from CCTA performed for CAD or suspected CAD to view and analyze coronary plaques/atherosclerosis and stenosis and support measurement and visualization of coronary arteries.
Which images or clinical context are in scope?Modality: CT/CTA Anatomy or clinical context: Heart; coronary arteries, plaques, and stenosis Input: DICOM 3.0-compliant or higher cardiac CT/CCTA images from any CT scanner.
Who uses it?Intended users: Trained medical professionals appropriately trained in the software's functions, capabilities, and limitations.
What does the software produce?Output: 2D/3D coronary visualization, editable lumen and vessel-wall segmentation, plaque/stenosis/vessel measurements, annotations for stents, CTOs, dominance, and anomalies, and an interactive CORONARY report that can send its text page to PACS.
What is its most important limitation?Key limitation: The software does not replace qualified medical judgment; users must account for interpolated data that may make tissue appear healthy, and outputs are based partly on user-editable segmentation and markers. No clinical testing was conducted for this v2.0 submission; the packet relies on non-clinical testing and previously reviewed predicate results.
Clinical takeaway
Clinical role: Web-based post-processing of cardiac CT data from CCTA performed for CAD or suspected CAD to view and analyze coronary plaques/atherosclerosis and stenosis and support measurement and visualization of coronary arteries.
Evidence takeaway
Evidence from the reviewed source record: K202280 reports no new clinical testing; non-clinical verification and validation supported the v2.0 intended use. Predicate-comparison results reproduced Pearson correlations of 0.91 lumen volume, 0.93 vessel volume, 0.85 total plaque volume, 0.94 calcified plaque volume, 0.74 non-calcified plaque volume, and 0.53 low-density non-calcified plaque volume, with Bland-Altman agreement of 96%, 97%, 95%, 95%, 95%, and 97%, respectively. These correlation and agreement endpoints are not sensitivity, specificity, or diagnostic accuracy.
Clinical details
What this tool is for
Start with the authorized purpose, then verify how it fits your service line and reading workflow.
Exact purpose
Web-based post-processing of cardiac CT data from CCTA performed for CAD or suspected CAD to view and analyze coronary plaques/atherosclerosis and stenosis and support measurement and visualization of coronary arteries.
Confirm the intended care setting, patient population, and service line.
Workflow role
Interactive post-processing, visualization, semi-automatic segmentation, manual editing, measurement, and CORONARY report generation to support CAD evaluation; the report is not the final physician report.
2D/3D coronary visualization, editable lumen and vessel-wall segmentation, plaque/stenosis/vessel measurements, annotations for stents, CTOs, dominance, and anomalies, and an interactive CORONARY report that can send its text page to PACS.
The software does not replace qualified medical judgment; users must account for interpolated data that may make tissue appear healthy, and outputs are based partly on user-editable segmentation and markers. No clinical testing was conducted for this v2.0 submission; the packet relies on non-clinical testing and previously reviewed predicate results.
The FDA listing establishes the regulatory identity. It does not by itself establish local workflow fit, pricing, security, or performance in your environment.
Use these fields to structure a vendor demo, security review, and implementation estimate.
Integration
Client-server Google Chrome application using DICOM 3.0 or higher and a secured network server; the packet describes sending the CORONARY report text page to PACS but does not establish specific PACS, RIS, EHR, hosting, or interface versions.
Deployment category preserved from the prior exact-submission review; hosting region, data flow, and current commercial configuration still require vendor confirmation.
ACR AI Central provides an exact-submission model card for Cleerly Labs v2.0; FDA labeling remains controlling for clinical use, limitations, and performance.
Metrics are shown only when they are tied to a source, endpoint, population, and tested product version. Candidate literature without exact product and version linkage is not shown as product evidence.
Evidence summary
K202280 reports no new clinical testing; non-clinical verification and validation supported the v2.0 intended use. Predicate-comparison results reproduced Pearson correlations of 0.91 lumen volume, 0.93 vessel volume, 0.85 total plaque volume, 0.94 calcified plaque volume, 0.74 non-calcified plaque volume, and 0.53 low-density non-calcified plaque volume, with Bland-Altman agreement of 96%, 97%, 95%, 95%, 95%, and 97%, respectively. These correlation and agreement endpoints are not sensitivity, specificity, or diagnostic accuracy.
No contextualized exact-version metric has completed evidence review. Regulatory-document values, when available, are shown above with their limitations.
Cleerly Labs V2.0 regulatory performance study summary
DesignStand-Alone Performance
PopulationPopulation described in the exact-submission ACR model card
Scopeexact submission
Tested versionExact product version not reported; regulatory study summarized for FDA submission K202280
IndependenceIndependence not established
K202280
ACR AI Central summarizes the regulatory study; consult the exact FDA materials before comparative use.
These are common procurement questions; unknown values remain visible until a source supports them.
Pricing and total cost
Vendor documentation pending
Vendor confirmation
Exact FDA submission
Checked 2026-09-09
No public price or quote for the exact K202280 configuration was established in this review.
Reimbursement and coding
Not established in reviewed sources
Reviewed sources checked
Exact FDA submission
Checked 2026-09-09
No exact-product payer policy, coding instruction, or payment determination was established; eligibility must be evaluated by payer, site of service, and use case.
Safety and lifecycle
Postmarket record
Recall and adverse-event records are shown only after product matching. Adverse-event reports do not establish incidence or causality.
Postmarket safety review
The exact-identifier FDA recall query returned no native recall record for K202280. This limited result does not establish absence of recalls or other safety information and does not cover later versions, family records, MAUDE reports, corrections, or field notices.
Verify care setting and population: Confirm the intended care setting, patient population, and service line.
Verify security and privacy controls: Exact-release security controls, data retention, hosting boundaries, and scoped assurance documentation require vendor confirmation.
Verify training: Current training prerequisites, competency checks, and support commitments for the exact configuration require vendor confirmation.
Verify pricing and total cost: No public price or quote for the exact K202280 configuration was established in this review.
Verify reimbursement and coding relevance: No exact-product payer policy, coding instruction, or payment determination was established; eligibility must be evaluated by payer, site of service, and use case.
Verify local validation and lifecycle monitoring: Current drift, quality, uptime, alert, escalation, and incident-response commitments for the exact configuration require vendor confirmation.
This audit distinguishes completed source review from fields that have not yet been researched.
Exact FDA record reviewedStatus
2026-09-20Last searched
23Fields reviewed
9Source classes checked
0Screened PubMed leads
1Screened trial leads
0Unreviewed FDA recall leads
The refreshed discovery snapshot contains 0 PubMed and 1 ClinicalTrials.gov candidate record. Discovery metadata alone does not establish exact tested-product, version, population, and endpoint applicability, so all candidates remain quarantined and none was promoted. The current discovery snapshot contains 0 PubMed and 1 ClinicalTrials.gov candidate records; its dated, count-matched human screening remains current. Unlinked candidates remain quarantined. Native FDA recall identifiers produced 0 postmarket candidate records; 0 have been reviewed (0 published, 0 rejected) and 0 remain unreviewed.
Candidate leads were screened against the exact product and tested version. Unlinked records remain quarantined.
Source classes: fda ai list, fda decision summary, acr ai central product, fda device recall, literature index, trial registry, pubmed, clinical trials, openfda device recall
Sources & history
How this profile was documented
Open the ledger for source dates, scope, and research-record updates.
View source ledger and history7 sources - 3 history items
cvi42 Coronary Plaque supports qualified professionals with viewing, post-processing, and qualitative and quantitative evaluation of adult cardiac CT DICOM images to assess the...
Adjunctive opportunistic detection and quantification of aortic valve calcification during routine clinical-care chest CT review; a physician reviews the informational ROI and...
vascuCAP analyzes contrast multidetector CT of arterial vessels to support atherosclerosis stratification with color maps, three-dimensional views, multiplanar reformats, and...