FDA-cleared profile

AVIEW

Coreline Soft Co., Ltd

AVIEW provides CT values for pulmonary tissue from thoracic and cardiac CT datasets and supports quantitative diagnosis, follow-up evaluation, and documentation through lung, lobe, airway, and cardiac segmentation, inspiration-expiration registration, air-trapping analysis, volumetric and density evaluation, nodule characterization, and reporting.

Evidence status: each field shows source quality, applicability, and review date. Research pending, information not established in reviewed sources, and vendor documentation pending are distinct outcomes.

Clinical fit

What this tool is for

Start with the authorized purpose, then verify how it fits your service line and reading workflow.

Exact purpose
AVIEW provides CT values for pulmonary tissue from thoracic and cardiac CT datasets and supports quantitative diagnosis, follow-up evaluation, and documentation through lung, lobe, airway, and cardiac segmentation, inspiration-expiration registration, air-trapping analysis, volumetric and density evaluation, nodule characterization, and reporting.
FDA source Exact FDA submission Checked 2026-09-04
Intended users
Trained radiologists and qualified physicians.
FDA source Exact FDA submission Checked 2026-09-04
Care setting and population
Thoracic and cardiac CT interpretation workflows in on-premise or supported cloud environments.
FDA source Exact FDA submission Checked 2026-09-04
Workflow role
CT segmentation, quantitative tissue and nodule analysis, registration, reporting, and image-management support.
FDA source Exact FDA submission Checked 2026-09-04
Required input
Thoracic and cardiac CT datasets received through DICOM 3.0 and supported study inputs.
FDA source Exact FDA submission Checked 2026-09-04
Output and human action
Lung, lobe, airway, cardiac, nodule, calcium, and related segmentations; measurements; quantitative values; reports; and DICOM or PDF results.
FDA source Exact FDA submission Checked 2026-09-04
Limitations
Exact feature, anatomy, scan protocol, patient, reconstruction, and deployment limits are release-specific; quantitative outputs require physician review and do not replace the complete CT interpretation.
FDA source Exact FDA submission Checked 2026-09-04

Regulatory identity

FDA record and catalog context

The FDA listing establishes the regulatory identity. It does not by itself establish local workflow fit, pricing, security, or performance in your environment.

FDA submission
K200714
FDA source Exact FDA submission Checked 2026-08-31
Modality
CT/CTA
FDA source Exact FDA submission Checked 2026-09-04
Anatomy
Lungs, lobes, airways, pulmonary nodules, and cardiac anatomy
FDA source Exact FDA submission Checked 2026-09-04
Clearance type
510(k)
FDA source Exact FDA submission Checked 2026-08-31
Decision date
2020-08-26
FDA source Exact FDA submission Checked 2026-08-31
FDA status
FDA-cleared
FDA source Exact FDA submission Checked 2026-08-31

Implementation

Questions for IT, informatics, and operations

Use these fields to structure a vendor demo, security review, and implementation estimate.

Integration
The FDA package describes DICOM 3.0 input, image reading and manipulation, storage, transfer, PDF reports, DICOM result files, on-premise or cloud dataset access, mobile devices, and a Chrome browser.
FDA source Exact FDA submission Checked 2026-09-04

This is the interface boundary described in the exact FDA package; current local compatibility, routing, identity, archive, and downtime behavior still require acceptance testing.

Deployment and data flow
The FDA package describes AVIEW use on premise and in a cloud environment with access from mobile devices and a Chrome browser; current hosting, contracts, availability, security, and site configuration remain unverified.
FDA source Exact FDA submission Checked 2026-09-04

This is the release-level boundary described in the exact FDA package; current hosting, contracts, security, availability, upgrade path, and site configuration remain separate evidence.

Security and privacy
Not established in reviewed sources
Reviewed sources checked Exact FDA submission Checked 2026-09-04

Public materials reviewed for this exact release do not establish the complete security posture. Request data-flow, identity, audit, encryption, retention, remote-access, vulnerability-management, backup, and incident-response evidence.

Training and support
Only trained radiologists and qualified physicians should operate or interpret the product. Local onboarding should cover the exact release, supported population, limitations, failure examples, escalation, downtime, and competency documentation.
FDA source Exact FDA submission Checked 2026-09-04
Monitoring and change control
Monitor K200714 by exact hardware, software, model, and algorithm version; patient population; anatomy; protocol; operator; input quality; output edits or overrides; failed studies; repeat acquisition or rework; downstream impact; downtime; incidents; recalls; and updates. Track these product-specific limits: Exact feature, anatomy, scan protocol, patient, reconstruction, and deployment limits are release-specific; quantitative outputs require physician review and do not replace the complete CT interpretation.
FDA source Exact FDA submission Checked 2026-09-04

This is buyer-facing monitoring guidance derived from the exact cleared or authorized scope; it is not a claim that the FDA package provides a live monitoring service.

Release and scope verification

Map installed model, build, options, population, anatomy, inputs, outputs, and enabled functions to K200714 before acceptance.

exact submission · checked 2026-09-04

Later product-family features are not evidence that this cleared or authorized release includes them.

Deployment boundary

The FDA package describes AVIEW use on premise and in a cloud environment with access from mobile devices and a Chrome browser; current hosting, contracts, availability, security, and site configuration remain unverified.

exact submission · checked 2026-09-04

FDA-described deployment boundaries do not establish current hosting contracts, security controls, uptime, or local qualification.

Interoperability acceptance

The FDA package describes DICOM 3.0 input, image reading and manipulation, storage, transfer, PDF reports, DICOM result files, on-premise or cloud dataset access, mobile devices, and a Chrome browser.

exact submission · checked 2026-09-04

Test representative identifiers, orientation, geometry, measurements, units, routing, failure handling, and round trips locally.

Clinical acceptance

Use a signed local test set for the supported population and workflow. Include common and difficult cases, exclusions, acquisition variation, failed or low-quality inputs, reviewer overrides, and downstream effects. Exact feature, anatomy, scan protocol, patient, reconstruction, and deployment limits are release-specific; quantitative outputs require physician review and do not replace the complete CT interpretation.

exact submission · checked 2026-09-04

Define stop-use, escalation, rollback, and revalidation triggers before production use.

Economic evaluation

Model capital and recurring cost against net staff time after review, throughput, repeat imaging or rework, room time, consumables, infrastructure, training, service, downtime, upgrade, and replacement costs.

product family · checked 2026-09-04

No exact-product price was found in the reviewed public material; productivity or value claims require local evidence.

Lifecycle monitoring

Monitor K200714 by exact hardware, software, model, and algorithm version; patient population; anatomy; protocol; operator; input quality; output edits or overrides; failed studies; repeat acquisition or rework; downstream impact; downtime; incidents; recalls; and updates. Track these product-specific limits: Exact feature, anatomy, scan protocol, patient, reconstruction, and deployment limits are release-specific; quantitative outputs require physician review and do not replace the complete CT interpretation.

exact submission · checked 2026-09-04

Revalidate after material software, hardware, model, protocol, interface, or clinical-policy changes. thoracic and cardiac CT analysis software limits remain submission-specific.

Evidence

Performance evidence

Metrics are shown only when they are tied to a source, endpoint, population, and tested product version.

Evidence summary
K200714 FDA decision material identifies the exact thoracic and cardiac CT analysis software, labeled use, and submission-specific verification or approval evidence. It does not establish product-wide sensitivity, specificity, outcomes, or independent clinical validation beyond the exact evidence summarized here.
FDA source Exact FDA submission Checked 2026-09-04
Reported sensitivity
Not applicable
Not applicable Not applicable Checked 2026-09-04

Sensitivity is not promoted as a product-wide endpoint. Compare only an exact endpoint, threshold, population, version, study design, and source if separately verified.

Reported specificity
Not applicable
Not applicable Not applicable Checked 2026-09-04

Specificity is not promoted as a product-wide endpoint. Compare only an exact endpoint, threshold, population, version, study design, and source if separately verified.

No contextualized exact-version metric has completed evidence review. Regulatory-document values, when available, are shown above with their limitations.

K200714 FDA evidence package for AVIEW

FDA 510(k) software verification, validation, and substantial-equivalence evidence for CT image analysis applications. · Lungs, lobes, airways, pulmonary nodules, and cardiac anatomy

exact submission · Tested version: AVIEW 2.0 configuration described in K200714 · Sponsor or vendor study

K200714

The FDA summary states that no clinical study was required before release because the indications were equivalent to the predicate; testing was verification and validation against predetermined pass/fail criteria.

Economics and lifecycle

Budget and ongoing governance

These are common procurement questions; unknown values remain visible until a source supports them.

Pricing and total cost
Not established in reviewed sources
Reviewed sources checked Exact FDA submission Checked 2026-09-04

No public list price for the exact cleared or authorized configuration was found. Obtain a written quote separating hardware or license basis, implementation, interfaces, infrastructure, training, service, upgrades, renewal, consumables, and exit costs.

Reimbursement and coding
No separate named-product Medicare payment was identified in the reviewed CMS coverage material. Evaluate the product within the applicable imaging or clinical service line and verify payer, site-of-service, coding, and coverage assumptions independently.
Public source Not applicable Checked 2026-09-04

No product-specific code

No separate named-product payment identified in reviewed public material

Centers for Medicare & Medicaid Services · United States

This is not a product-specific reimbursement determination. Build a local total-cost and value model and verify payer, site-of-service, coding, and coverage assumptions independently.

Safety and lifecycle

Postmarket record

Recall and adverse-event records are shown only after product matching. Adverse-event reports do not establish incidence or causality.

Postmarket safety review
The 2026-09-02 openFDA device-recall snapshot contained no record matched to K200714 by exact native submission identifier. This does not exclude product-family, later-version, or adverse-event information.
Public source Exact FDA submission Checked 2026-09-04

Exact-identifier review does not prove absence of all product-family safety signals.

Buyer worksheet

Open questions to take to the vendor

Open evaluation checklist

Research record

What has been checked

This audit distinguishes completed source review from fields that have not yet been researched.

Human reviewedStatus
2026-09-04Last searched
26Fields reviewed
12Source classes checked
20Reviewed PubMed leads
4Reviewed trial leads
0Unreviewed FDA recall leads

Twenty PubMed records and four trial records were screened. Exact Coreline records identify AVIEW versions 1.1.42.92, 2.5, 1.1.39.14, or another build rather than AVIEW 2.0 in K200714; remaining records are unrelated AView names or lack exact version linkage, so all 24 are quarantined. The current discovery snapshot contains 20 PubMed and 4 ClinicalTrials.gov candidate records; its dated, count-matched human screening remains current. Unlinked candidates remain quarantined. Native FDA recall identifiers produced 0 postmarket candidate records; 0 have been reviewed (0 published, 0 rejected) and 0 remain unreviewed.

Candidate leads were screened against the exact product and tested version. Unlinked records remain quarantined.

Source classes: fda ai list, fda decision summary, acr ai central product, fda decision material, fda pma record, peer reviewed literature, clinical trial registry, reimbursement policy, fda device recall, pubmed, clinical trials, openfda device recall

Sources

Source ledger

Sources accessed through 2026-09-04.

Alternatives

Related tools to compare

FDA-cleared K214036

AVIEW

Coreline Soft Co.,Ltd.

AVIEW provides quantitative CT analysis of pulmonary and cardiac anatomy, including lung, lobe, airway, fissure, nodule, coronary calcium, and related measurements and reports to...

Modality
CT/CTA
Anatomy
Lungs, lobes, airways, fissures, heart, coronary arteries, and pulmonary nodules
Decision
2022-12-23
FDA-cleared K252029

AI-CVD

HeartLung Corporation

AI-CVD provides automated quantitative CT-derived anatomical and density measurements for clinician review, including calcium scores, cardiac and vascular measurements, lung and...

Modality
CT/CTA
Anatomy
Chest, abdomen, heart, lungs, liver, aorta, pulmonary artery, bone, muscle, and fat
Decision
2025-12-19