FDA-cleared profile

Avenda Health AI Prostate Cancer Planning Software

Avenda Health, Inc.

The Avenda Health AI Prostate Cancer Planning Software is an artificial intelligence (AI)-based decision support software, indicated as an adjunct to the review of magnetic resonance (MR) prostate images and biopsy findings in the prostate oncological workflow. The Avenda Health AI Prostate Cancer Planning Software is designed to support the prostate oncological workflow by helping the user with the segmentation of MR image features, including the prostate; in the evaluation, quantification, and documentation of lesions; and in pre-planning for diagnostic and interventional procedures such as biopsy and/or soft tissue ablation. The device is intended to be used by physicians trained in the oncological workflow in a clinical setting for planning and guidance for clinical, interventional, diagnostic, and/or treatment procedures of the prostate. The Avenda Health AI Prostate Planning Software may also be used as a medical image application, for the viewing, manipulation, 3D-visualization, and comparison of MR prostate images. The images can be viewed in a number of output formats including volume

Evidence status: each field shows source quality, applicability, and review date. Research pending, information not established in reviewed sources, and vendor documentation pending are distinct outcomes.

Clinical fit

What this tool is for

Start with the authorized purpose, then verify how it fits your service line and reading workflow.

Exact purpose
The Avenda Health AI Prostate Cancer Planning Software is an artificial intelligence (AI)-based decision support software, indicated as an adjunct to the review of magnetic resonance (MR) prostate images and biopsy findings in the prostate oncological workflow. The Avenda Health AI Prostate Cancer Planning Software is designed to support the prostate oncological workflow by helping the user with the segmentation of MR image features, including the prostate; in the evaluation, quantification, and documentation of lesions; and in pre-planning for diagnostic and interventional procedures such as biopsy and/or soft tissue ablation. The device is intended to be used by physicians trained in the oncological workflow in a clinical setting for planning and guidance for clinical, interventional, diagnostic, and/or treatment procedures of the prostate. The Avenda Health AI Prostate Planning Software may also be used as a medical image application, for the viewing, manipulation, 3D-visualization, and comparison of MR prostate images. The images can be viewed in a number of output formats including volume
Public source Exact FDA submission Checked 2026-09-01

Exact-submission indication text from the ACR AI Central model card. FDA labeling remains controlling.

Intended users
Physicians trained in the oncological workflow (Radiologist/Urologist)
Public source Exact FDA submission Checked 2026-09-01

Intended-user text reported in the exact-submission ACR model card.

Care setting and population
Research pending
Needs research Exact FDA submission Checked 2026-08-31

Confirm the intended care setting, patient population, and service line.

Workflow role
Segmentation or contouring
Public source Exact FDA submission Checked 2026-09-01

Conservative normalization of explicit wording in an exact-submission source.

Required input
MR images or data. Inclusion criteria: Patients with a pathology-confirmed Gleason Grade Group (GGG) >= 2 lesion and for whom corresponding biopsy coordinate information have been uploaded; MR prostate images (T2-weighted MRI); biopsy, pathology, and clinical data
Public source Exact FDA submission Checked 2026-09-01

Conservative normalization of explicit wording in an exact-submission source.

Output and human action
The AI model outputs: (1) Cancer Estimation Map - assigns a probability to each voxel within the prostate indicating its probability for containing clinically significant prostate cancer (csPCa, GGG >= 2); (2) Default Lesion Contour - a boundary of the lesion created by user-selected threshold on the cancer map; (3) Encapsulation Confidence Score - indicating the confidence that all csPCa is encapsulated within the boundary, derived from a lookup table generated by a database of cases with known ground-truth. The device also provides prostate gland segmentation, volume measurements, lesion location and volume, and 3D visualization of MR prostate images.
Public source Exact FDA submission Checked 2026-09-01

Clinical output reported in the exact-submission ACR model card.

Limitations
Scanner manufacturers: All
Public source Exact FDA submission Checked 2026-09-01

Limitations and supported-acquisition details reported in the exact-submission ACR model card.

Regulatory identity

FDA record and catalog context

The FDA listing establishes the regulatory identity. It does not by itself establish local workflow fit, pricing, security, or performance in your environment.

FDA submission
K221624
FDA source Exact FDA submission Checked 2026-08-31
Modality
MRI
Public source Exact FDA submission Checked 2026-09-01

Imaging modality reported in the exact-submission ACR AI Central model card.

Anatomy
Prostate
Public source Exact FDA submission Checked 2026-09-01

Anatomy normalized from explicit exact-submission ACR model-card wording.

Clearance type
510(k)
FDA source Exact FDA submission Checked 2026-08-31
Decision date
2022-11-22
FDA source Exact FDA submission Checked 2026-08-31
FDA status
FDA-cleared
FDA source Exact FDA submission Checked 2026-08-31

Implementation

Questions for IT, informatics, and operations

Use these fields to structure a vendor demo, security review, and implementation estimate.

Integration
Standards-based DICOM/PACS integration was identified in the FDA submission materials; compatibility with a specific PACS, RIS, EHR, or orchestrator requires confirmation.
Public source Exact FDA submission Checked 2026-08-13

Normalized from the prior exact-submission review. Confirm interface versions and local compatibility during technical evaluation.

Deployment and data flow
On-cloud
Public source Exact FDA submission Checked 2026-08-13

Deployment category preserved from the prior exact-submission review; hosting region, data flow, and current commercial configuration still require vendor confirmation.

Security and privacy
Vendor documentation pending
Vendor confirmation Exact FDA submission Checked 2026-08-13

FDA authorization does not establish the current commercial security posture. Request data-flow diagrams, hosting and retention details, access controls, audit logging, attestations, and incident-response documentation.

Training and support
Vendor documentation pending
Vendor confirmation Exact FDA submission Checked 2026-08-13

Training, onboarding, competency, and support commitments are commercial implementation details that require current vendor documentation.

Monitoring and change control
Vendor documentation pending
Vendor confirmation Exact FDA submission Checked 2026-08-13

Local acceptance testing, production monitoring, drift review, update control, and incident escalation require a current vendor and site-specific governance plan.

Supported acquisition environment

Scanner manufacturers: All

exact submission · checked 2026-09-01

Confirm currently supported software versions, protocols, and site-specific acquisition configurations.

Evidence

Performance evidence

Metrics are shown only when they are tied to a source, endpoint, population, and tested product version.

Evidence summary
Study type: Both. Cases: 137. Reader-study sensitivity: 97.40%
Public source Exact FDA submission Checked 2026-09-01

Structured study metadata from the exact-submission ACR model card; this is not an independent evidence synthesis.

Reported sensitivity
97.4%
FDA source Exact FDA submission Checked 2026-08-13

Values reported in the exact-submission materials. Consult the linked source for endpoint, threshold, population, and confidence interval before comparison.

Reported specificity
72.1%
FDA source Exact FDA submission Checked 2026-08-13

Values reported in the exact-submission materials. Consult the linked source for endpoint, threshold, population, and confidence interval before comparison.

No contextualized exact-version metric has completed evidence review. Regulatory-document values, when available, are shown above with their limitations.

Avenda Health AI Prostate Cancer Planning Software regulatory performance study summary

Stand-alone performance and reader study (ACR AI Central category) · Population described in the exact-submission ACR model card

exact submission · Tested version: Exact product version not reported; regulatory study summarized for FDA submission K221624 · n=137 · Independence not established

K221624

ACR AI Central summarizes the regulatory study; consult the exact FDA materials before comparative use.

Economics and lifecycle

Budget and ongoing governance

These are common procurement questions; unknown values remain visible until a source supports them.

Pricing and total cost
Vendor documentation pending
Vendor confirmation Exact FDA submission Checked 2026-08-13

FDA submission materials do not establish current commercial pricing. Request the pricing unit, term, minimum commitment, implementation fees, and included support from the vendor.

Reimbursement and coding
Research pending
Needs research Exact FDA submission Checked 2026-08-31

Determine whether any product-specific CPT/HCPCS pathway exists and separate it from billing for the underlying imaging service.

Safety and lifecycle

Postmarket record

Recall and adverse-event records are shown only after product matching. Adverse-event reports do not establish incidence or causality.

Postmarket safety review
Not established in reviewed sources
Reviewed sources checked Exact FDA submission Checked 2026-09-04

No native submission-identifier match was found in the checked openFDA radiology recall snapshot. Product-name, manufacturer, and adverse-event searches remain necessary; this does not establish that no recall or safety report exists.

Buyer worksheet

Open questions to take to the vendor

Open evaluation checklist

Research record

What has been checked

This audit distinguishes completed source review from fields that have not yet been researched.

Exact FDA record reviewedStatus
2026-09-04Last searched
19Fields reviewed
6Source classes checked
0Unreviewed PubMed leads
0Unreviewed trial leads
0Unreviewed FDA recall leads

Exact-submission ACR model-card fields were normalized under the current provenance rules; vendor and independent-study confirmation remain distinct. Automated exact-name discovery found 0 PubMed and 0 ClinicalTrials.gov candidate records. Candidates require human product and version matching; zero candidates is not evidence that no studies exist. Native FDA recall identifiers produced 0 postmarket candidate records; 0 have been reviewed (0 published, 0 rejected) and 0 remain unreviewed.

Candidate leads remain unpublished until a human confirms the exact product and tested version.

Source classes: fda ai list, fda decision summary, acr ai central product, pubmed, clinical trials, openfda device recall

Sources

Source ledger

Sources accessed through 2026-09-02.

Alternatives

Related tools to compare

FDA-cleared K202501

Quantib Prostate

Quantib BV

Quantib Prostate is image post-processing software for processing, visualizing, and editing prostate MRI images. It supports registered multiparametric-MRI viewing, optional...

Modality
MRI
Anatomy
Prostate
Decision
2020-10-11
FDA-cleared K253682

DeepHealth ProstateAI

Quantib B.V.

FDA product code QDQ identifies this device class as Radiological Computer Assisted Detection/Diagnosis Software For Lesions Suspicious For Cancer. A radiological computer...

Modality
MRI
Anatomy
Prostate
Decision
2026-04-29
FDA-cleared K242683

QP-Prostate® CAD

Quibim S.L.

FDA product code QDQ identifies this device class as Radiological Computer Assisted Detection/Diagnosis Software For Lesions Suspicious For Cancer. A radiological computer...

Modality
MRI
Anatomy
Prostate
Decision
2025-03-18
FDA-cleared K241770

Prostate MR AI (VA10A)

Siemens Healthcare GmbH

Prostate MR AI (VA10A) is a plug-in CADe/CADx aid for radiologists interpreting prostate MRI in adult men aged 40 years or older with suspected prostate cancer and no prior...

Modality
MRI
Anatomy
Prostate
Decision
2025-03-05