FDA-cleared profile

Aquilion Prime SP (TSX-303B8) V10.2 with AiCE-i

Canon Medical Systems Corporation · CT/CTA · FDA-cleared (510(k))

Authorized purpose: Aquilion Prime SP with AiCE-i supports the labeled CT acquisition, reconstruction, visualization, and professional-interpretation workflow for the cleared scanner configuration.

Clinical role
CT acquisition, reconstruction, visualization, analysis, and professional review support.
Images and patients
CT/CTA · Multi-region
Key limitation
Keep in mind: Scanner, protocol, contrast, dose, patient-size, anatomy, reconstruction, and optional-analysis limits vary by exact submission and release. Aquilion Prime SP with AiCE-i supports the labeled CT acquisition, reconstruction, visualization, and professional-interpretation workflow for the cleared scanner configuration.

Overview status: Source-reviewed overview

Report a correction
Clinical details Purpose, workflow fit, evidence, and safety record

Workflow navigation pilot

Workflow role has not yet been reviewed for this navigation pilot.

A tag identifies a documented role; it does not establish compatibility or local acceptance. Methods and sources

  • What does this software do?Authorized purpose: Aquilion Prime SP with AiCE-i supports the labeled CT acquisition, reconstruction, visualization, and professional-interpretation workflow for the cleared scanner configuration.
  • Which images or clinical context are in scope?Modality: CT/CTA Anatomy or clinical context: Multi-region Input: Patient CT acquisitions, reconstruction data, and release-specific protocol or DICOM metadata.
  • Who uses it?Intended users: Qualified radiologic technologists and interpreting physicians.
  • What does the software produce?Output: Cross-sectional CT images, reconstructions, measurements, and release-specific derived image objects for professional review.
  • What is its most important limitation?Key limitation: Scanner, protocol, contrast, dose, patient-size, anatomy, reconstruction, and optional-analysis limits vary by exact submission and release. Aquilion Prime SP with AiCE-i supports the labeled CT acquisition, reconstruction, visualization, and professional-interpretation workflow for the cleared scanner configuration.

Clinical takeaway. Clinical role: Aquilion Prime SP with AiCE-i supports the labeled CT acquisition, reconstruction, visualization, and professional-interpretation workflow for the cleared scanner configuration.

Evidence takeaway. Evidence from the reviewed source record: The exact FDA submission K192832 is the identity anchor. Its public decision material supports the submission-specific product and intended-use summary recorded here; it does not establish a general product-wide sensitivity or specificity value for this dossier.

Purpose
Aquilion Prime SP with AiCE-i supports the labeled CT acquisition, reconstruction, visualization, and professional-interpretation workflow for the cleared scanner configuration.
  • Exact FDA submission
  • Checked 2026-09-04
Workflow role
CT acquisition, reconstruction, visualization, analysis, and professional review support.
  • Exact FDA submission
  • Checked 2026-09-04
Required input
Patient CT acquisitions, reconstruction data, and release-specific protocol or DICOM metadata.
  • Exact FDA submission
  • Checked 2026-09-04
Output and clinician action
Cross-sectional CT images, reconstructions, measurements, and release-specific derived image objects for professional review.
  • Exact FDA submission
  • Checked 2026-09-04
Care setting
Hospital and outpatient CT departments using the cleared scanner, protocol, and software configuration.
  • Exact FDA submission
  • Checked 2026-09-04
Intended users
Qualified radiologic technologists and interpreting physicians.
  • Exact FDA submission
  • Checked 2026-09-04
Limitations
Scanner, protocol, contrast, dose, patient-size, anatomy, reconstruction, and optional-analysis limits vary by exact submission and release. Aquilion Prime SP with AiCE-i supports the labeled CT acquisition, reconstruction, visualization, and professional-interpretation workflow for the cleared scanner configuration.
  • Exact FDA submission
  • Checked 2026-09-04
Evidence summary
The exact FDA submission K192832 is the identity anchor. Its public decision material supports the submission-specific product and intended-use summary recorded here; it does not establish a general product-wide sensitivity or specificity value for this dossier.
  • Exact FDA submission
  • Checked 2026-09-04

Evidence

Performance evidence

Metrics are shown only when they are tied to a source, endpoint, population, and tested product version. Candidate literature without exact product and version linkage is not shown as product evidence.

Evidence summary
The exact FDA submission K192832 is the identity anchor. Its public decision material supports the submission-specific product and intended-use summary recorded here; it does not establish a general product-wide sensitivity or specificity value for this dossier.
  • FDA source
  • Exact FDA submission
  • Checked 2026-09-04
Reported sensitivity
Not established in reviewed sources
  • Reviewed sources checked
  • Exact FDA submission
  • Checked 2026-09-04

No exact submission and version-linked sensitivity endpoint is published in this dossier; do not substitute a product-family or candidate-study value.

Reported specificity
Not established in reviewed sources
  • Reviewed sources checked
  • Exact FDA submission
  • Checked 2026-09-04

No exact submission and version-linked specificity endpoint is published in this dossier; do not substitute a product-family or candidate-study value.

No contextualized exact-version metric has completed evidence review. Regulatory-document values, when available, are shown above with their limitations.

FDA submission-specific verification and validation evidence for K192832

  • DesignRegulatory verification, validation, and labeling evidence reviewed for exact FDA submission K192832.
  • PopulationThe labeled population and test materials for exact submission K192832; a general clinical study population is not established here.
  • Scopeexact submission
  • Tested versionAquilion Prime SP (TSX-303B8) V10.2 with AiCE-i (K192832)
  • IndependenceSponsor or vendor study

K192832

FDA regulatory evidence is submission-specific but is not independent clinical performance evidence.

Safety and lifecycle

Postmarket record

Recall and adverse-event records are shown only after product matching. Adverse-event reports do not establish incidence or causality.

Postmarket safety review
FDA recall Z-0549-2021 is associated with native exact submission identifier K192832. Status: Terminated. Product: Canon Aquilion Prime SP, Multislice Helical CT Scanner, TSX-303B/8L - Product Usage: intended to acquire and display cross-sectional volumes of the whole body, including the head.. Reason: A software problem has been identified which could result in the CT Scanner not proceeding to the next actual scan even though automatic start of the next scan is specified. This could result in the CT scan failing resulting in rescanning and reinjection of contrast medium.
  • FDA source
  • Exact FDA submission
  • Checked 2026-09-04

Each published event was manually matched to the exact FDA submission and affected product or version; a recall does not establish an AI-algorithm defect or current site exposure unless the event states that scope.

recall: Z-0549-2021

Terminated

2020-11-09

Native exact-submission identifier match from the openFDA candidate snapshot accessed 2026-09-04 with source snapshot date 2026-09-02. Source URL: https://api.fda.gov/device/recall.json?search=product_res_number.exact%3A%22Z-0549-2021%22&limit=1. This does not establish exact installed serial, lot, unit, or software-version applicability.

Pricing & contracts Public price, contract terms, and reimbursement

Price not public here; enter your quote

Not publicly available: Reviewed sources do not publish an exact-product procurement price with a stated offer scope.

Reimbursement

IT implementation Deployment, interfaces, data handling, and support

System and version relationships

Match the AI release, system build, configuration and region. Source documentation does not establish acceptance of an installed system.

No specific system/version pairing has completed review for this FDA record. A broad DICOM or product-family statement does not establish a named viewer build's support.

Review Merge, Visage, Sectra, AGFA and IntelePACS context

Local implementation checklist

Agree the evidence and acceptance owner with your team and suppliers. Checkmarks apply to this page only and are not acceptance receipts.

Open the printable evaluation checklist

Integration
Standards-based DICOM/PACS integration was identified in the FDA submission materials; compatibility with a specific PACS, RIS, EHR, or orchestrator requires confirmation.
  • Exact FDA submission
  • Checked 2026-08-13

Normalized from the prior exact-submission review. Confirm interface versions and local compatibility during technical evaluation.

Security
Canon Medical's cybersecurity page states that Canon imaging systems follow a software development life cycle governed by the NIST 800-53 Risk Management Framework adhering to Defense Health Agency certification requirements; FIPS 140-2 certified cipher standards; deny-all firewall configuration and near-real-time SIEM syslog export as premium offerings; a dedicated cybersecurity risk management team for threat intelligence monitoring, advisories and incident response; and published OS and third-party update policies. Vendor statement; no certification or test report was read.
  • Vendor-wide
  • Checked 2026-10-26

Vendor statement, not an attestation. Identity bridge: the page is on us.medical.canon, Canon Medical's own site (Canon Medical Systems USA), and describes Canon Medical imaging devices generally; the FDA applicant is Canon Medical Systems Corporation, named in the corporate name-change press release on the same domain. Regional page with general device claims; exact-release scope is not established.

Training
The 510(k) summary states the Aquilion Prime SP volume sets can be used to perform specialized studies, using indicated software/hardware, by a trained and qualified physician.
  • Exact FDA submission
  • Checked 2026-10-27

User qualification wording only; the summary specifies no training program or training offering for this device.

Workflow role

CT acquisition, reconstruction, visualization, analysis, and professional review support.

exact submission · checked 2026-09-04

This is a submission-anchored intended-use summary, not a local acceptance result.

Input

Patient CT acquisitions, reconstruction data, and release-specific protocol or DICOM metadata.

exact submission · checked 2026-09-04

Exact supported inputs and protocol limits must be confirmed from the complete labeling.

Output

Cross-sectional CT images, reconstructions, measurements, and release-specific derived image objects for professional review.

exact submission · checked 2026-09-04

Output review, editing, and downstream use remain release- and site-specific.

Vendor family context

Current vendor material is product-family context for K192832 only; exact release, enabled options, deployment, and local interoperability require confirmation.

product family · checked 2026-09-04

Vendor material is not exact-release evidence unless that linkage is separately proven.

Site validation status

Exact local interfaces, deployment topology, security controls, downtime behavior, and support obligations remain unestablished.

exact submission · checked 2026-09-04

Obtain organization-specific implementation evidence before procurement or clinical use.

Sources & review details FDA identity, research record, source ledger, and history

Regulatory identity

FDA record and catalog context

The FDA listing establishes the regulatory identity. It does not by itself establish local workflow fit, pricing, security, or performance in your environment.

FDA submission
K192832
  • FDA source
  • Exact FDA submission
  • Checked 2026-08-31
Modality
CT/CTA
  • FDA source
  • Exact FDA submission
  • Checked 2026-09-04
Anatomy
Multi-region
  • FDA source
  • Exact FDA submission
  • Checked 2026-09-04
Clearance type
510(k)
  • FDA source
  • Exact FDA submission
  • Checked 2026-08-31
Decision date
2020-02-21
  • FDA source
  • Exact FDA submission
  • Checked 2026-08-31
FDA status
FDA-cleared
  • FDA source
  • Exact FDA submission
  • Checked 2026-08-31

Research record

What has been checked

This audit distinguishes completed source review from fields that have not yet been researched.

Human reviewedStatus
2026-09-04Last searched
29Fields reviewed
13Source classes checked
0Screened PubMed leads
0Screened trial leads
0Unreviewed FDA recall leads

The refreshed discovery snapshot contains no PubMed or ClinicalTrials.gov candidates; no external evidence was promoted. The current discovery snapshot contains 0 PubMed and 0 ClinicalTrials.gov candidate records; its dated, count-matched human screening remains current. Unlinked candidates remain quarantined. 1 FDA recall candidate was manually reviewed: 1 published and 0 rejected as a neighboring or otherwise inapplicable version. Native FDA recall identifiers produced 1 postmarket candidate record; 1 has been reviewed (1 published, 0 rejected) and 0 remain unreviewed.

Candidate leads were screened against the exact product and tested version. Unlinked records remain quarantined.

Source classes: fda ai list, fda decision summary, vendor product page, implementation documentation, reimbursement policy, peer reviewed literature, clinical trial registry, fda device recall, literature index, trial registry, pubmed, clinical trials, openfda device recall

Field review details

Recorded state, verification date, notes and sources for fields without a publishable value. Conflicting records stay explicitly unsettled here; no plain settled value is shown for them.

  • Public pricing: Not publicly available - checked 2026-09-04 - Exact FDA submission

    No public exact-release price, license fee, subscription, contract, or implementation cost was established in this review.

  • Pricing model: Not yet reviewed
  • Setup and integration fees: Not yet reviewed
  • Recurring fees: Not yet reviewed
  • Minimum commitment: Not yet reviewed
  • Contract duration: Not yet reviewed
  • Renewal terms: Not yet reviewed
  • Cancellation terms: Not yet reviewed
  • Support and service terms: Not yet reviewed
  • Trial or pilot terms: Not yet reviewed
  • Reimbursement: Not applicable - checked 2026-09-04 - Not applicable

    CMS index context was checked, but no product-specific coverage or reimbursement determination is inferred.

  • Deployment: Not publicly available - checked 2026-09-04 - Exact FDA submission

    Exact deployment topology, hosting, network boundaries, update mechanism, and local operational requirements are not established for this submission.

  • Data hosting location: Not yet reviewed
  • Data retention: Not yet reviewed
  • Documented data use: Not yet reviewed
  • Hardware requirements: Not yet reviewed
  • Network requirements: Not yet reviewed
  • Identity and access: Not yet reviewed
  • Installation timeline: Not yet reviewed
  • Monitoring: Not verified - checked 2026-10-27 - Exact FDA submission

    Current drift, quality, uptime, alert, escalation, and incident-response commitments for the exact configuration require vendor confirmation.

9 sources - 3 history items

Source ledger

  1. FDA decision summary for K192832 - Aquilion Prime SP (TSX-303B8) V10.2 with AiCE-i

    U.S. Food and Drug Administration - Published 2020-02-21 - Accessed 2026-09-04

    Scope: regulatoryIdentity, productIdentity, indication, modality, anatomy, workflowRole, input, output, limitations, evidenceSummary

  2. Artificial Intelligence-Enabled Medical Devices

    U.S. Food and Drug Administration - Accessed 2026-08-31

    Scope: regulatoryIdentity, modalityContext

  3. FDA recall Z-0549-2021: Canon Aquilion Prime SP, Multislice Helical CT Scanner, TSX-303B/8L - Product Usage: intended to acquire and display cross-sectional volumes of the whole body, including the head.

    U.S. Food and Drug Administration - Accessed 2026-09-04

    Scope: postmarketSafety, affectedProduct, recallStatus, correctiveAction

  4. PubMed biomedical literature index

    U.S. National Library of Medicine - Accessed 2026-09-01

    Scope: evidenceDiscovery

  5. ClinicalTrials.gov study registry

    U.S. National Library of Medicine - Accessed 2026-09-01

    Scope: evidenceDiscovery, studyStatus

  6. Medicare Coverage Database

    Centers for Medicare & Medicaid Services - Accessed 2026-09-01

    Scope: coverage, codingContext

  7. openFDA Device Recall API

    U.S. Food and Drug Administration - Accessed 2026-09-02

    Scope: recallDiscovery, nativeSubmissionMatching

  8. Canon Medical Aquilion CT family context

    Canon Medical Systems - Accessed 2026-09-04

    Scope: productFamilyContext, workflowRole, implementationCapabilities

  9. Canon Medical: Medical Imaging Cybersecurity

    Canon Medical Systems USA - Accessed 2026-10-26

    Scope: security

Research history

  1. K192832 FDA decision

    Regulatory record

    510(k)

  2. Source-review record updated

    Research record

    human reviewed

  3. Reader overview source-reviewed

    Editorial review

    Source-reviewed editorial overlay

Alternatives

Related tools to compare

FDA-cleared K253649

Spectral CT Verida Family

Philips Medical Systems Technologies, Ltd.

Authorized purpose: Spectral CT Verida Family supports the labeled spectral CT acquisition, reconstruction, material-map, and professional-interpretation workflow; exact models, protocols, and derived outputs remain submission-specific.

Modality
CT/CTA
Anatomy
Multi-region
Decision
2026-03-27
FDA-cleared K253574

SOMATOM X.cite; SOMATOM X.ceed

Siemens Medical Solutions USA, Inc.

Authorized purpose: SOMATOM X.cite and X.ceed with syngo CT VB20 support diagnostic CT, interventions, treatment preparation, radiation-therapy planning, and qualified low-dose lung screening.

Modality
CT/CTA
Anatomy
Multi-region
Decision
2026-03-20
FDA-cleared K243523

NAEOTOM Alpha.Peak/ NAEOTOM Alpha; NAEOTOM Alpha.Pro; NAEOTOM Alpha.Prime

Siemens Medical Solutions USA, Inc.

Authorized purpose: NAEOTOM Alpha.Peak, Alpha, Alpha.Pro, and Alpha.Prime are photon-counting CT systems for diagnostic cross-sectional imaging, treatment and interventional support, low-dose lung-cancer screening under approved protocols, and radiation-therapy planning.

Modality
CT/CTA
Anatomy
Multi-region
Decision
2025-02-12
FDA-cleared K232491

CT 5300

Philips Healthcare (Suzhou) Co., Ltd.

CT 5300 acquires head and whole-body cross-sectional CT images for diagnosis in adult and pediatric patients and supports low-dose lung-cancer screening under approved protocols.

Modality
CT/CTA
Anatomy
Multi-region
Decision
2024-05-03