Input or output interoperability
DICOM is explicitly referenced in the described input, output, or workflow.
exact submission · checked 2026-09-01The model card does not establish every supported DICOM object, transfer method, or local interface.
FDA-cleared profile
Siemens Healthcare GmBh
AI-Rad Companion (Pulmonary) is image processing software that provides quantitative and qualitative analysis from previously acquired Computed Tomography DICOM images to support radiologists and physicians from emergency medicine, specialty care, urgent care, and general practice in the evaluation and assessment of disease of the lungs. It provides the following functionality: Segmentation and measurements of complete lung and lung lobes Identification of areas with lower Hounsfield values in comparison to a predefined threshold for complete lung and lung lobes Providing an interface to external Medical Device syngo.CT Lung CAD Segmentation and measurements of solid lung nodules. Dedication of found lung nodules to corresponding lung lobe. Correlation of segmented lung nodules of current scan with known priors and quantitative assessment of changes of the correlated data. Identification of areas with elevated Hounsfield values, where areas with elevated versus high opacities are distinguished. The software has been validated for data from Siemens Healthineers (filtered back projection and iterative reconstruction),GE Healthcare (filtered back projection reconstruction), and Philips (filtered back projection reconstruction).Only DI COM images of adult patients are considered to be valid input.
Product overview
AI-Rad Companion (Pulmonary) is image processing software that provides quantitative and qualitative analysis from previously acquired Computed Tomography DICOM images to support radiologists and physicians from emergency medicine, specialty care, urgent care, and general practice in the evaluation and assessment of disease of the lungs. It provides the following functionality: Segmentation and measurements of complete lung and lung lobes Identification of areas with lower Hounsfield values in comparison to a predefined threshold for complete lung and lung lobes Providing an interface to external Medical Device syngo.CT Lung CAD Segmentation and measurements of solid lung nodules. Dedication of found lung nodules to corresponding lung lobe. Correlation of segmented lung nodules of current scan with known priors and quantitative assessment of changes of the correlated data. Identification of areas with elevated Hounsfield values, where areas with elevated versus high opacities are distinguished. The software has been validated for data from Siemens Healthineers (filtered back projection and iterative reconstruction),GE Healthcare (filtered back projection reconstruction), and Philips (filtered back projection reconstruction).Only DI COM images of adult patients are considered to be valid input.
Overview status: Field-derived fact summary This section is assembled from the sourced field records below; it is not a source-reviewed editorial overview.
Clinical details
Start with the authorized purpose, then verify how it fits your service line and reading workflow.
Intended-user text reported in the exact-submission ACR model card.
Patient-population text reported in the exact-submission ACR model card; institutional setting may still require vendor confirmation.
Conservative normalization of explicit wording in an exact-submission source.
Conservative normalization of explicit wording in an exact-submission source.
Clinical output reported in the exact-submission ACR model card.
Limitations and supported-acquisition details reported in the exact-submission ACR model card.
Regulatory identity
The FDA listing establishes the regulatory identity. It does not by itself establish local workflow fit, pricing, security, or performance in your environment.
Implementation
Use these fields to structure a vendor demo, security review, and implementation estimate.
Interoperability terms explicitly reported in the exact-submission ACR model card; interface versions and local compatibility still require confirmation.
Deployment category preserved from the prior exact-submission review; hosting region, data flow, and current commercial configuration still require vendor confirmation.
Exact-release security controls, data retention, hosting boundaries, and scoped assurance documentation require vendor confirmation.
Current training prerequisites, competency checks, and support commitments for the exact configuration require vendor confirmation.
Current drift, quality, uptime, alert, escalation, and incident-response commitments for the exact configuration require vendor confirmation.
DICOM is explicitly referenced in the described input, output, or workflow.
exact submission · checked 2026-09-01The model card does not establish every supported DICOM object, transfer method, or local interface.
Scanner manufacturers: All
exact submission · checked 2026-09-01Confirm currently supported software versions, protocols, and site-specific acquisition configurations.
ACR AI Central provides an exact-submission model card for AI-Rad Companion (Pulmonary); FDA labeling remains controlling for clinical use, limitations, and performance.
exact submission · checked 2026-09-08Evidence
Metrics are shown only when they are tied to a source, endpoint, population, and tested product version. Candidate literature without exact product and version linkage is not shown as product evidence.
Structured study metadata from the exact-submission ACR model card; this is not an independent evidence synthesis.
Model sensitivity reported by ACR AI Central. Review endpoint, threshold, study population, and tested version before comparison.
This field has not been curated yet.
No contextualized exact-version metric has completed evidence review. Regulatory-document values, when available, are shown above with their limitations.
K213713
ACR AI Central summarizes the regulatory study; consult the exact FDA materials before comparative use.
Costs and setup
These are common procurement questions; unknown values remain visible until a source supports them.
No public price or quote for the exact K213713 configuration was established in this review.
No exact-product payer policy, coding instruction, or payment determination was established; eligibility must be evaluated by payer, site of service, and use case.
Safety and lifecycle
Recall and adverse-event records are shown only after product matching. Adverse-event reports do not establish incidence or causality.
Buyer worksheet
Research record
This audit distinguishes completed source review from fields that have not yet been researched.
Exact-submission ACR model-card fields were normalized under the current provenance rules; vendor and independent-study confirmation remain distinct. Exact FDA scope controls clinical claims. ACR and official vendor material provide bounded catalog or product-family context. Candidate literature metadata remains a discovery queue until full-text identity, endpoint, population, and version review is completed. Automated exact-name discovery found 20 PubMed and 1 ClinicalTrials.gov candidate records. Candidates require human product and version matching; zero candidates is not evidence that no studies exist. Native FDA recall identifiers produced 0 postmarket candidate records; 0 have been reviewed (0 published, 0 rejected) and 0 remain unreviewed.
Candidate leads remain unpublished until a human confirms the exact product and tested version.
Source classes: fda ai list, fda decision summary, acr ai central product, fda device recall, literature index, trial registry, pubmed, clinical trials, openfda device recall
Sources & history
Open the ledger for source dates, scope, and research-record updates.
Scope: identity, clinicalUse, modality, anatomy, workflow, evidence, implementation
Scope: regulatoryIdentity, modalityContext
Scope: intendedUsers, careSetting, output, limitations, reportedSensitivity, evidenceSummary, integration, anatomy, evidenceStudies, implementationCapabilities
Scope: evidenceDiscovery
Scope: evidenceDiscovery, studyStatus
Scope: recallDiscovery, nativeSubmissionMatching
Scope: postmarketSafety
Regulatory record
510(k)
Research record
fda record reviewed
Alternatives
Median Technologies
eyonis LCS is a concurrent-reading aid for radiologists that detects, localizes, and characterizes 4-30 mm solid and part-solid pulmonary nodules on low-dose chest CT images for...
Infervision Medical Technology Co., Ltd.
Adjunctive pulmonary nodule detection and measurement, including temporal comparison, in chest CT screening of asymptomatic adults aged at least 55 years.
Siemens Healthcare GmbH
Assist radiologists in detecting solid and subsolid pulmonary nodules during review of multivendor multi-detector CT examinations of the chest; the device is an adjunctive first-...
Coreline Soft Co.,Ltd.
Adjunctive detection of 3-20 mm pulmonary nodules in chest CT examinations for asymptomatic populations, including second-reader use.